Heat exchanger fouling in phosphoric acid evaporators

被引:6
|
作者
Behbahani, R. M.
Mueller-Steinhagen, H.
Jamialahmadi, M.
机构
[1] German Aerosp Ctr, Inst Tech Thermodynam, D-70569 Stuttgart, Germany
[2] Univ Stuttgart, Inst Thermodynam & Thermal Engn, D-7000 Stuttgart, Germany
[3] Petr Univ Technol, Res Dept, Ahvaz, Iran
关键词
D O I
10.1080/01457630601122468
中图分类号
O414.1 [热力学];
学科分类号
摘要
Multistage shell and tube evaporators are frequently used in phosphoric acid plants to increase the concentration of dilute phosphoric acid to 52-55 wt% P2O5. The concentrated phosphoric acid solution is supersaturated with respect to calcium sulfate. As a result, part of the calcium sulfate in the liquor deposits on the heat exchanger tube walls. Because the thermal conductivity of these scales is very low, thin deposits can create a significant resistance to heat transfer. Therefore, regular cleaning of heat exchangers is required, frequently at shorter than biweekly intervals. As the major costs in modern phosphoric acid plants are the cost of energy, a thorough understanding of the fouling kinetics and of the effects of various operational parameters on the behavior of calcium sulfate is required to improve operation and design of the shell and tube heat exchangers, which are extensively used. In this investigation, a large set of heat exchanger data was collected from shell and tube heat exchangers of the phosphoric acid plant of the Razi Petrochemical Complex in Iran, and the fouling deposits were analyzed with respect to appearance and composition. The overall heat transfer coefficients and fouling resistances were evaluated at different times, and a kinetic model for the crystallization fouling was developed. It is shown that the crystallization rate constant obeys an Arrhenius relationship with an activation energy of 57 kJ/mol. The average absolute error of 12.4% shows that the predictions of the suggested model are in good agreement with the original plant data.
引用
收藏
页码:292 / 298
页数:7
相关论文
共 50 条
  • [1] Heat exchanger fouling and cleaning in the dihydrate process for the production of phosphoric acid
    Jamialahmadi, M.
    Mueller-Steinhagen, H.
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2007, 85 (A2): : 245 - 255
  • [2] Estimation of fouling resistance in a phosphoric acid/steam heat exchanger using inverse method
    Fguiri, Ali
    Marvillet, Christophe
    Jeday, Mohamed Razak
    [J]. APPLIED THERMAL ENGINEERING, 2021, 192
  • [3] Heat exchangers fouling in phosphoric acid concentration
    Fguiri, Ali
    Jradi, Rania
    Marvillet, Christophe
    Jeday, Mohamed Razak
    [J]. HEAT AND MASS TRANSFER, 2020, 56 (07) : 2313 - 2324
  • [4] Heat exchangers fouling in phosphoric acid concentration
    Ali Fguiri
    Rania Jradi
    Christophe Marvillet
    Mohamed Razak Jeday
    [J]. Heat and Mass Transfer, 2020, 56 : 2313 - 2324
  • [5] Fouling in heat exchanger
    不详
    [J]. MATERIALS PERFORMANCE, 2007, 46 (04) : 62 - 62
  • [6] PLATE HEAT EXCHANGER USED AS EVAPORATORS
    Ilie, A.
    Drughean, L.
    Hera, D.
    [J]. 23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 2597 - 2603
  • [7] Estimation and sensitivity analysis of fouling resistance in phosphoric acid/steam heat exchanger using artificial neural networks and regression methods
    Jradi, Rania
    Marvillet, Christophe
    Jeday, Mohamed Razak
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01)
  • [8] TEMPERATURE OF PHOSPHORIC-ACID IN CONTACT EVAPORATORS
    POPOV, NP
    BUGRIN, VP
    LYKOV, MV
    GALTSOV, AV
    [J]. JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1975, 48 (01): : 230 - 231
  • [9] Estimation and sensitivity analysis of fouling resistance in phosphoric acid/steam heat exchanger using artificial neural networks and regression methods
    Rania Jradi
    Christophe Marvillet
    Mohamed Razak Jeday
    [J]. Scientific Reports, 13
  • [10] Conquer heat exchanger fouling
    Mukherjee, R