Imaging of a mixture of hyperpolarized 3He and 129Xe

被引:8
|
作者
Acosta, RH
Blümler, P
Han, S
Appelt, S
Häsing, FW
Schmiedeskamp, J
Heil, W
Spiess, HW
机构
[1] Max Planck Inst Polymer Res, D-55128 Mainz, Germany
[2] Univ Calif Santa Barbara, Dept Chem & Biochem, Santa Barbara, CA 93106 USA
[3] Res Ctr Julich, Cent Lab Elect, D-52428 Julich, Germany
[4] Johannes Gutenberg Univ Mainz, Dept Phys, D-55099 Mainz, Germany
关键词
MRI; hyperpolarized gases; Xe; He; lungs;
D O I
10.1016/j.mri.2004.08.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With the use of hyperpolarized gases, a great number of experiments have been carried out in order to improve the diagnostics of the lung, both from a structural and a functional point of view. He-3 is best suited for structural studies, whereas Xe-129 gives more detailed information about the functionality of the lung because it enters the bloodstream. In this work, we propose the use of a gas mixture to perform consecutive analysis of lung structure and functionality upon the delivery of a single bolus of gas. We show images of a helium-xenon gas mixture in the presence of a small amount of liquid toluene in order to demonstrate how both nuclei can be detected independently, extracting the spectroscopic information provided by the Xe-129 spectra and obtaining an image with high sensitivity for He-3. A second experiment performed on a dissected mouse lung was used to demonstrate how the mixture of gases can enhance sensitivity in the larger airways of the lung. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:1077 / 1083
页数:7
相关论文
共 50 条
  • [1] Translational applications of hyperpolarized 3He and 129Xe
    Walkup, Laura L.
    Woods, Jason C.
    NMR IN BIOMEDICINE, 2014, 27 (12) : 1429 - 1438
  • [2] Comparison of Hyperpolarized 3He and 129Xe MR Imaging in Cystic Fibrosis Patients
    Shammi, Ummul Afia
    D'Alessandro, Michelle Felicia
    Altes, Talissa
    Hersman, F. William
    Ruset, Iulian C.
    Mugler, John, III
    Meyer, Craig
    Mata, Jamie
    Qing, Kun
    Thomen, Robert
    ACADEMIC RADIOLOGY, 2022, 29 : S82 - S90
  • [3] COMPARISON OF HYPERPOLARIZED 3HE AND 129XE MR IMAGING IN CYSTIC FIBROSIS PATIENTS
    Shammi, U.
    D'Alessandro, M.
    Altes, T.
    Hersman, F.
    Ruset, I
    Mugler, J.
    Meyer, C.
    Mata, J.
    Qing, K.
    Thomen, R. P.
    PEDIATRIC PULMONOLOGY, 2020, 55 : S212 - S212
  • [4] Comparison of Hyperpolarized 3He and 129Xe MR Imaging in Patients with Cystic Fibrosis
    Koch, M. F.
    Mugler, J. P.
    Mata, J. F.
    Qing, K.
    Tustison, N. J.
    Altes, T. A.
    Thomen, R. P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [5] Hyperpolarized 3He and 129Xe MRI: Differences in Asthma Before Bronchodilation
    Svenningsen, Sarah
    Kirby, Miranda
    Starr, Danielle
    Leary, Del
    Wheatley, Andrew
    Maksym, Geoffrey N.
    McCormack, David G.
    Parraga, Grace
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (06) : 1521 - 1530
  • [6] Hyperpolarized 3He and 129Xe MR Imaging in Healthy Volunteers and Patients with Chronic Obstructive Pulmonary Disease
    Kirby, Miranda
    Svenningsen, Sarah
    Owrangi, Amir
    Wheatley, Andrew
    Farag, Adam
    Ouriadov, Alexei
    Santyr, Giles E.
    Etemad-Rezai, Roya
    Coxson, Harvey O.
    McCormack, David G.
    Parraga, Grace
    RADIOLOGY, 2012, 265 (02) : 600 - 610
  • [7] Comparison of Hyperpolarized 3He and 129Xe MRI for the Measurement of Absolute Ventilated Lung Volume in Rats
    Fox, Matthew S.
    Ouriadov, Alexei
    Santyr, Giles E.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 1130 - 1136
  • [8] Ventilation heterogeneity imaged by multibreath wash-ins of hyperpolarized 3He and 129Xe in healthy rabbits
    Hamedani, Hooman
    Kadlecek, Stephen
    Ruppert, Kai
    Xin, Yi
    Duncan, Ian
    Rizi, Rahim R.
    JOURNAL OF PHYSIOLOGY-LONDON, 2021, 599 (17): : 4197 - 4223
  • [9] Assessment of lung microstructure in ILD with 3He and 129Xe MRI
    Stewart, Neil J.
    Norquay, Graham
    Parra-Robles, Juan
    Marshall, Helen
    Leung, General
    Murphy, Philip S.
    Schulte, Rolf F.
    Elliot, Charlie A.
    Condliffe, Robin
    Billings, Catherine G.
    Smith, Ian
    Griffiths, Paul D.
    Wolber, Jan
    Whyte, Moira K.
    Kiely, David G.
    Wild, Jim M.
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [10] Hyperpolarised gas filling station for medical imaging using polarised 129Xe and 3He
    Lee, Wai Tung
    Zheng, Gang
    Talbot, Cavin L.
    Tong, Xin
    D'Adam, Tim
    Parnell, Steven R.
    de Veer, Michael
    Jenkin, Graham
    Polglase, Graeme R.
    Hooper, Stuart B.
    Thompson, Bruce R.
    Thien, Francis
    Egan, Gary F.
    MAGNETIC RESONANCE IMAGING, 2021, 79 : 112 - 120