Lesion detectability in stereoscopically viewed digital breast tomosynthesis projection images: a model observer study with anthropomorphic computational breast phantoms

被引:0
|
作者
Reinhold, Jacob [1 ,2 ]
Wen, Gezheng [2 ,3 ]
Lo, Joseph Y. [4 ]
Markey, Mia K. [5 ,6 ]
机构
[1] Univ Texas Austin, Appl Res Labs, Austin, TX 78712 USA
[2] Univ Texas Austin, Dept Elect & Comp Engn, Austin, TX 78712 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
[4] Duke Univ, Sch Med, Dept Radiol, Durham, NC 27703 USA
[5] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA
[6] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
关键词
Model observer; stereo matching; digital breast tomosynthesis; disparity estimation; lesion detection; POPULATION; DENSITY; NOISE;
D O I
10.1117/12.2255909
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Stereoscopic views of 3D breast imaging data may better reveal the 3D structures of breasts, and potentially improve the detection of breast lesions. The imaging geometry of digital breast tomosynthesis (DBT) lends itself naturally to stereo viewing because a stereo pair can be easily formed by two projection images with a reasonable separation angle for perceiving depth. This simulation study attempts to mimic breast lesion detection on stereo viewing of a sequence of stereo pairs of DBT projection images. 3D anthropomorphic computational breast phantoms were scanned by a simulated DBT system, and spherical signals were inserted into different breast regions to imitate the presence of breast lesions. The regions of interest (ROI) had different local anatomical structures and consequently different background statistics. The projection images were combined into a sequence of stereo pairs, and then presented to a stereo matching model observer for determining lesion presence. The signal-to-noise ratio (SNR) was used as the figure of merit in evaluation, and the SNR from the stack of reconstructed slices was considered as the benchmark. We have shown that: 1) incorporating local anatomical backgrounds may improve lesion detectability relative to ignoring location-dependent image characteristics. The SNR was lower for the ROIs with the higher local power-law-noise coefficient 3. 2) Lesion detectability may be inferior on stereo viewing of projection images relative to conventional viewing of reconstructed slices, but further studies are needed to confirm this observation.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Implementation of an anthropomorphic model observer using convolutional neural network for breast tomosynthesis images
    Lee, Changwoo
    Baek, Jongduk
    [J]. MEDICAL IMAGING 2020: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2020, 11316
  • [2] Multislice anthropomorphic model observer for detectability evaluation on breast cone beam CT images
    Han, Minah
    Baek, Jongduk
    [J]. 15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [3] Effect of Dose Level on Radiologists' Detection of Microcalcifications in Digital Breast Tomosynthesis: An Observer Study with Breast Phantoms
    Chan, Heang-Ping
    Helvie, Mark A.
    Klein, Katherine A.
    McLaughlin, Carol
    Neal, Colleen H.
    Oudsema, Rebecca
    Rahman, W. Tania
    Roubidoux, Marilyn A.
    Hadjiiski, Lubomir M.
    Zhou, Chuan
    Samala, Ravi K.
    [J]. ACADEMIC RADIOLOGY, 2022, 29 : S42 - S49
  • [4] Experimental phantom lesion detectability study using a digital breast tomosynthesis prototype system
    Schulz-Wendtland, R.
    Wenkel, E.
    Lell, M.
    Boehner, C.
    Bautz, W. A.
    Mertelmeier, T.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2006, 178 (12): : 1219 - 1223
  • [5] Digital Breast Tomosynthesis: Observer Performance Study
    Gur, David
    Abrams, Gordon S.
    Chough, Denise M.
    Ganott, Marie A.
    Hakim, Christiane M.
    Perrin, Ronald L.
    Rathfon, Grace Y.
    Sumkin, Jules H.
    Zuley, Margarita L.
    Bandos, Andriy I.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (02) : 586 - 591
  • [6] Foveated Model Observer to Predict Human Search Performance on Virtual Digital Breast Tomosynthesis Phantoms
    Lago, Miguel A.
    Barufaldi, Bruno
    Bakic, Predrag R.
    Abbey, Craig K.
    Maidment, Andrew D.
    Eckstein, Miguel P.
    [J]. MEDICAL IMAGING 2020: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2020, 11316
  • [7] Digital breast tomosynthesis: A pilot observer study
    Good, Walter F.
    Abrams, Gordon S.
    Catullo, Victor J.
    Chough, Denise M.
    Ganott, Marie A.
    Hakim, Christiane M.
    Gur, David
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) : 865 - 869
  • [8] Model and human observer reproducibility for detecting microcalcifications in digital breast tomosynthesis images
    Petrov, Dimitar
    Marshall, Nicholas
    Young, Kenneth
    Bosmans, Hilde
    [J]. MEDICAL IMAGING 2018: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2018, 10577
  • [9] Masses detection in breast tomosynthesis and digital mammography: a model observer study
    Castella, C.
    Ruschin, M.
    Eckstein, M. P.
    Abbey, C. K.
    Kinkel, K.
    Verdun, F. R.
    Tingberg, A.
    Bochud, F. O.
    [J]. MEDICAL IMAGING 2009: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2009, 7263
  • [10] Evaluating Breast Tomosynthesis with a Multi-Projection Observer for Arbitrary Lesion Shapes
    Mainprize, J. G.
    Yaffe, M. J.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E532 - E533