A novel 3D-printed batch injection analysis (BIA) cell coupled to paper-based electrochemical devices: A cheap and reliable analytical system for fast on-site analysis

被引:8
|
作者
Ferreira, Marcos Eduardo da Silva [1 ]
de Moraes, Natalia Canhete [1 ]
Ferreira, Valdir Souza [1 ]
da Silva, Rodrigo Amorim Bezerra [2 ]
Petroni, Jacqueline Marques [1 ,3 ]
Lucca, Bruno Gabriel [1 ,3 ]
机构
[1] Univ Fed Mato Grosso, Chem Inst, BR-79074460 Campo Grande, MS, Brazil
[2] Univ Fed Uberlandia, Inst Quim, BR-38500000 Monte Carmelo, MG, Brazil
[3] Univ Fed Mato Grosso, Inst Chem, BR-79074460 Campo Grande, MS, Brazil
关键词
Additive manufacturing; 5-hydroxytryptophan; Carbon electrodes; Electroanalysis; Paper analytical devices; Pharmaceutical analysis; SCREEN-PRINTED ELECTRODES; AMPEROMETRIC DETECTION; HIGH-THROUGHPUT; 5-HYDROXYTRYPTOPHAN; QUANTIFICATION; CHROMATOGRAPHY; COMBINATION;
D O I
10.1016/j.microc.2022.107663
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports, for the first time, the association of electrochemical paper analytical devices (ePADs) with batch injection analysis (BIA) systems. The novel 3D-printed BIA cell utilized here is semi-transparent (3Dprinted by SLA/DLP technology), while the three-electrode paper device was fabricated by pencil drawing. This ePAD/3D-BIA platform was employed for the amperometric detection of 5-hydroxytryptophan (5-HTP). To the best of our knowledge, this is the first BIA method for determining this analyte. The parameters of the method were studied and optimized. The ePAD/3D-BIA system presented good repeatability and reproducibility, with relative standard deviations (RSDs) < 5%, besides high analytical frequency (180 injections per hour). In addition, the ePAD showed excellent performance and lifetime, being able to be utilized for up to eight consecutive days. Under the best conditions, amperometric response of 5-HTP provided linearity in the range of 0.165 to 150 mu mol L-1, with a limit of detection (LOD) of 50 nmol L-1. As a proof of principle, the ePAD/3D-BIA was used to analyze 5-HTP in commercial food/pharmaceutical samples. The results presented great precision (RSD <= 1.5%) and agreement with the values obtained by UV-vis spectrophotometry (95% confidence level). These findings show the potential of the novel system proposed here. The ePAD/3D-BIA proved to be an efficient, fast and reliable platform that can be a useful tool for the analysis of electroactive species. Moreover, the very low cost, practicality and simplicity may offer interesting advantages over conventional BIA systems.
引用
收藏
页数:8
相关论文
共 14 条
  • [1] Microfluidic Paper-based Analytical Devices for On-site Environmental Analysis
    Umeda, Mika I.
    Kaneta, Takashi
    BUNSEKI KAGAKU, 2024, 73 (09) : 433 - 439
  • [2] A Compact Batch Injection Analysis Cell for Screen Printed Electrodes: A Portable Electrochemical System for On-site Analysis
    Richter, Eduardo M.
    Tormin, Thiago F.
    Cunha, Rafael R.
    Silva, Weberson P.
    Perez-Junquera, Alejandro
    Fanjul-Bolado, Pablo
    Hernandez-Santos, David
    Munoz, Rodrigo A. A.
    ELECTROANALYSIS, 2016, 28 (08) : 1856 - 1859
  • [3] Paper-based enzymatic reactors for batch injection analysis of glucose on 3D printed cell coupled with amperometric detection
    Dias, Anderson A.
    Cardoso, Thiago M. G.
    Cardoso, Rafael M.
    Duarte, Lucas C.
    Munoz, Rodrigo A. A.
    Richter, Eduardo M.
    Coltro, Wendell K. T.
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 226 : 196 - 203
  • [4] Fabrication of paper-based analytical devices using a PLA 3D-printed stencil for electrochemical determination of chloroquine and escitalopram
    Martin K. L. Silva
    Guilherme S. Sousa
    Rafael P. Simoes
    Ivana Cesarino
    Journal of Solid State Electrochemistry, 2022, 26 : 581 - 586
  • [5] Fabrication of paper-based analytical devices using a PLA 3D-printed stencil for electrochemical determination of chloroquine and escitalopram
    Silva, Martin K. L.
    Sousa, Guilherme S.
    Simoes, Rafael P.
    Cesarino, Ivana
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2022, 26 (02) : 581 - 586
  • [6] Couple batch-injection analysis and microfluidic paper-based analytical device: A simple and disposable alternative to conventional BIA apparatus
    Arantes, Iana V. S.
    Paixao, Thiago R. L. C.
    TALANTA, 2022, 240
  • [7] Simple, Miniaturized, Adaptable, Robust and Transportable (SMART) 3D-printed electrochemical cell: A friendly tool for on-site and forensic analysis
    Novais, Augusto dos Santos
    Ribeiro, Daiane Gabriela
    Melo, Larissa Magalhaes de Almeida
    Ferrari Junior, Ettore
    Arantes, Luciano Chaves
    Lucca, Bruno Gabriel
    de Melo, Edmar Isaias
    Brocenschi, Ricardo Francisco
    de Santos, Wallans Torres Pio
    da Silva, Rodrigo Amorim Bezerra
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 398
  • [8] Compact and on-demand 3D-printed optical device based on silicone optical technology (SOT) for on-site measurement: Application to flow injection analysis
    Malasuk, C.
    Nakakubo, K.
    Ishimatsu, R.
    Nakashima, Y.
    Yoshioka, H.
    Morita, K.
    Oki, Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (10):
  • [9] A simple method to produce 2D and 3D microfluidic paper-based analytical devices for clinical analysis
    de Oliveira, Ricardo A. G.
    Camargo, Fiamma
    Pesquero, Naira C.
    Faria, Ronaldo Censi
    ANALYTICA CHIMICA ACTA, 2017, 957 : 40 - 46
  • [10] A paper-based screen-printed electrochemical sensor combined with a 3D printed extracting cartridge for analysis of phosphorus in Antarctic lacustrine sediments
    Seddaoui, Narjiss
    Di Gregorio, Chiara
    Gullo, Ludovica
    Argiriadis, Elena
    Arduini, Fabiana
    TALANTA, 2025, 289