Development of a Compatible Exoskeleton (Co-Exos II) for Upper-Limb Rehabilitation

被引:0
|
作者
Zhang, Leiyu [1 ,2 ]
Li, Jianfeng [1 ,2 ]
Dong, Minjie [1 ,2 ]
Cui, Ying [3 ]
Rong, Xi [4 ]
机构
[1] Beijing Univ Technol, Coll Mech & Elect Engn, Beijing, Peoples R China
[2] Beijing Univ Technol, Beijing Key Lab Adv Mfg Technol, Beijing, Peoples R China
[3] China Janpan Friendship Hosp, Dept Gynaecol & Obstet, Beijing, Peoples R China
[4] Qingdao Univ, Dept Neurol, Affiliated Hosp, Qingdao, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
ROBOT; ARMIN;
D O I
10.1109/urai.2019.8768641
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A key approach for reducing motor impairment and regaining independence after spinal cord injuries or strokes is frequent and repetitive functional training. A compatible exoskeleton (Co-Exos II) is proposed for the upper-limb rehabilitation. A compatible configuration was selected according to optimum configuration principles. Four passive translational joints were introduced into the connecting interfaces to adapt the glenohumeral joint (GH) movements and improve the compatibility of the exoskeleton. This configuration of the passive joints could reduce the influence of gravity of the exoskeleton device and the upper extremities. A Co-Exos II prototype was developed and still owned a compact volume. A new approach was presented to compensate the vertical GH movements. The shoulder closed-loop was simplified as a guide-bar mechanism. The compatible models of this loop were established based on the kinematic model of GH. The compatible experiments were completed to verify the kinematic models and analyze the human-machine compatibility of Co-Exos II. The theoretical displacements of the translational joints were calculated by the kinematic model of the shoulder loop. The passive joints exhibited good compensations for the GH movements through comparing the theoretical and measured results, especially vertical GH movements. Co-Exos II showed good human-machine compatibility for upper limbs.
引用
收藏
页码:240 / 245
页数:6
相关论文
共 50 条
  • [1] Design and human-machine compatibility analysis of Co-Exos II for upper-limb rehabilitation
    Zhang, Leiyu
    Li, Jianfeng
    Ji, Shuting
    Su, Peng
    Tao, Chunjing
    Ji, Run
    ASSEMBLY AUTOMATION, 2019, 39 (04) : 715 - 726
  • [2] Compatible Exoskeleton Design for Upper-limb Rehabilitation Based on VR Technology
    You, Zhenwei
    Liu, Jian
    Zou, Feng
    Wang, Xiaochun
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 127 : 75 - 75
  • [3] Development of Upper-Limb Exoskeleton Simulator for Passive Rehabilitation
    Huang, Jian-Bin
    Hong, Jing-Chen
    Young, Kuu-Young
    Ko, Chun-Hsu
    2014 CACS INTERNATIONAL AUTOMATIC CONTROL CONFERENCE (CACS 2014), 2014, : 335 - 339
  • [4] Exoskeleton robots for upper-limb rehabilitation
    Bouteraa, Yassine
    Ben Abdallah, Ismail
    2016 13TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2016, : 6 - 11
  • [5] Requirements for Upper-Limb Rehabilitation with FES and Exoskeleton
    Kim, Woojin
    Joe, Hyunwoo
    Kim, HyunSuk
    Lee, Seung-Jun
    Yoon, Daesub
    Jung, Je Hyung
    Acuna, Borja Bornail
    Lee, Hooman
    Raton, Javier Finez
    Isoird, Carlos Fernandez
    Marinelarena, Iker
    Alonso, Miguel Angel Aldudo
    Shin, Myung Jun
    Park, Tae Sung
    INTELLIGENT HUMAN COMPUTER INTERACTION, IHCI 2020, PT II, 2021, 12616 : 172 - 177
  • [6] An Affordable Upper-Limb Exoskeleton Concept for Rehabilitation Applications
    Palazzi, Emanuele
    Luzi, Luca
    Dimo, Eldison
    Meneghetti, Matteo
    Vicario, Rudy
    Luzia, Rafael Ferro
    Vertechy, Rocco
    Calanca, Andrea
    TECHNOLOGIES, 2022, 10 (01)
  • [7] CLEVERarm: A Lightweight and Compact Exoskeleton for Upper-Limb Rehabilitation
    Zeiaee, Amin
    Zarrin, Rana Soltani
    Eib, Andrew
    Langari, Reza
    Tafreshi, Reza
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2022, 7 (02) : 1880 - 1887
  • [8] The analysis and control of exoskeleton upper-limb rehabilitation robot
    Wang, Lan
    Yin, Zhengqian
    Sun, Yuanhang
    Key Engineering Materials, 2014, 572 (01) : 619 - 623
  • [9] Development and Control of a Bowden-Cable Actuated Exoskeleton for Upper-Limb Rehabilitation
    Wu, Qingcong
    Wang, Xingsong
    Du, Fengpo
    Xu, Jigang
    2014 IEEE INTERNATIONAL SYMPOSIUM ON ROBOTIC AND SENSORS ENVIRONMENTS (ROSE 2014), 2014,
  • [10] Research on control system of an exoskeleton upper-limb rehabilitation robot
    Wang L.
    Hu X.
    Hu J.
    Fang Y.
    He R.
    Yu H.
    Yu, Hongliu (yhl98@hotmail.com), 1600, West China Hospital, Sichuan Institute of Biomedical Engineering (33): : 1168 - 1175