Construction of a conformal water bolus vest applicator for hyperthermia treatment of superficial skin cancer

被引:0
|
作者
Juang, T [1 ]
Neuman, D [1 ]
Schlorff, J [1 ]
Stauffer, PR [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
来源
PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7 | 2004年 / 26卷
关键词
breast cancer; conformal microwave array; radiation therapy; superficial hyperthermia;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Large area chestwall recurrence of breast carcinoma can be treated with moderate temperature hyperthermia in combination with radiation or chemotherapy. For diffuse chestwall disease, hyperthermia is best delivered with a conformal microwave array (CMA) applicator using a temperature-controlled water bolus designed specifically to fit complex contours and maintain contact with the tissue surface to prevent air gaps which distort the microwave power deposition pattern. In order to maintain the desired temperature range of 41-45degreesC during local hyperthermia treatments, it is necessary to have an effective fluid flow system to serve as a buffer and prevent overheating of skin, which can lead to small blisters or, in rare cases, deeper burns. The fluid flow dynamics of a vest shaped open water bag design is evaluated with thermometry during a step temperature change of circulating water. The data confirm the feasibility of uniform circulation and temperature control throughout complex bolus shapes. This water bolus design should improve temperature uniformity of current treatments for superficial tissue disease.
引用
收藏
页码:3467 / 3470
页数:4
相关论文
共 50 条
  • [1] Construction of a Conformal Applicator for Hyperthermia Treatment of Superficial Skin Cancer
    Koo, Yun Seo
    Fathy, Aly E.
    Kazemi, Robab
    Phillips, Jeffrey
    2012 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM (APSURSI), 2012,
  • [2] Hyperthermia is Performance of Conformal Applicator for Limb Tumor in Presence of Water Bolus
    Singh, Soni
    Sahu, Bhagirath
    Singh, S. P.
    2017 INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (ISAP 2017), 2017,
  • [3] WATER BOLUS TEMPERATURE AND SUPERFICIAL HYPERTHERMIA
    ASTRAHAN, MA
    LUXTON, G
    MEDICAL PHYSICS, 1985, 12 (04) : 514 - 514
  • [4] Hyperthermia applicator for small superficial tumor treatment
    Togni, P.
    Vrba, J.
    Vannucci, L.
    PIERS 2008 CAMBRIDGE, PROCEEDINGS, 2008, : 775 - +
  • [5] Conformal Hyperthermia of Superficial Tumor With Left-Handed Metamaterial Lens Applicator
    Tao, Yonghui
    Wang, Gang
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (12) : 3525 - 3530
  • [6] Conformal Multilayer Hyperthermia Applicators for Superficial Cancer Treatment in Veterinary Patients
    Koo, Yun Seo
    Kazemi, Robab
    Phillips, Jeffrey
    Fathy, Aly E.
    2013 IEEE TOPICAL CONFERENCE ON BIOMEDICAL WIRELESS TECHNOLOGIES, NETWORKS, AND SENSING SYSTEMS (BIOWIRELESS), 2013, : 52 - 54
  • [7] Development of a guideline for the water bolus temperature in superficial hyperthermia
    Van der Gaag, M. L.
    de Bruijne, M.
    Samaras, T.
    Van der Zee, J.
    Van Rhoon, G. C.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2006, 22 (08) : 637 - 656
  • [8] A multiwell applicator for conformal brachytherapy of superficial skin tumors: A simulation study
    Pashazadeh, Ali
    Robatjazi, Mostafa
    Castro, Nathan J.
    Friebe, Michael
    SKIN RESEARCH AND TECHNOLOGY, 2020, 26 (04) : 537 - 541
  • [9] Conformal hyperthermia of superficial tumor with cylindrical left-handed metamaterial lens applicator
    Tao Y.
    Wang G.
    Prog. Electromagn. Res. C, (1-10): : 1 - 10
  • [10] A MICROWAVE HYPERTHERMIA SYSTEM WITH MULTIELEMENT APPLICATOR FOR TREATMENT OF SUPERFICIAL TUMORS
    HAND, JW
    JOHNSON, RH
    JAMES, JR
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1987, 3 (06) : 566 - 567