Basophil counting in hematology analyzers: time to discontinue?

被引:3
|
作者
Hoffmann, Johannes J. M. L. [1 ]
机构
[1] H3L Consult, Nuenen, Netherlands
关键词
analytical reliability; basophils; flow cytometry; hematology analyzer; CELL-DYN-SAPPHIRE; FLOW-CYTOMETRY; PERFORMANCE EVALUATION; DIFFERENTIAL COUNT; CELLAVISION DM96; QUALITY-CONTROL; SYSMEX XE-2100; HEMALOG-D; BLOOD; PSEUDOBASOPHILIA;
D O I
10.1515/cclm-2020-1528
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Basophils (basophilic granulocytes) are the least abundant cells in blood. Nowadays, basophils are included in the complete blood count performed by hematology analyzers and therefore reported in practically all patients in whom hematologic investigations are requested. However, hematology analyzers are not reliable enough to report clinically useful results. This is due to a combination of very high analytical imprecision and poor specificity, because the chemical and physical methods used for basophil counting in hematology analyzers are ill-defined and thus basophils are not well recognized by the analyzers. As a result, false basophil counts are quite common. In view of increasing analytical performance demands, hematology laboratories should stop reporting basophil counts produced by hematology analyzers. Suggestions for alternative pathways are presented for those situations where basophils are of clinical relevance.
引用
收藏
页码:813 / 820
页数:8
相关论文
共 50 条
  • [1] Basophil counting by hematology analyzers in cases of suspected chronic myeloid leukemia
    Hoffmann, Johannes
    [J]. IRAQI JOURNAL OF HEMATOLOGY, 2022, 11 (01) : 89 - 90
  • [2] Evaluation of hematology analyzers for platelet counting.
    Kline, L
    Dabay, M
    Wahab, F
    [J]. TRANSFUSION, 2002, 42 (09) : 54S - 55S
  • [3] Platelet counting using various hematology cell analyzers
    Dijkstra-Tiekstra, M. J.
    Kuipers, W.
    Setroikromo, A.
    de Wildt-Eggen, J.
    [J]. VOX SANGUINIS, 2006, 91 : 267 - 267
  • [4] Flowcytometric analysis of basophil counts in human blood and inaccuracy of hematology analyzers
    Ducrest, S
    Meier, F
    Tschopp, C
    Pavlovic, R
    Dahinden, CA
    [J]. ALLERGY, 2005, 60 (11) : 1446 - 1450
  • [5] Platelet counting in platelet concentrates with various automated hematology analyzers
    Dijkstra-Tiekstra, Margriet J.
    Kuipers, Willeke
    Setroikromo, Airies C.
    de Wildt-Eggen, Janny
    [J]. TRANSFUSION, 2007, 47 (09) : 1651 - 1657
  • [6] Prospective comparisons of platelet counting in automated hematology analyzers.
    Whitbread, J
    Moroff, G
    Coker, SO
    Finch, S
    Murphy, S
    Wenz, B
    [J]. TRANSFUSION, 1998, 38 (10) : 86S - 86S
  • [7] Multicenter comparison of counting platelets using different hematology analyzers
    Van der Meer, P. F.
    Mahon, A.
    De Wildt-Eggen, J.
    [J]. TRANSFUSION, 2006, 46 (09) : 70A - 70A
  • [8] The role of laboratory hematology between technology and professionalism: the paradigm of basophil counting
    Tosato, Francesca
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (05) : 821 - 822
  • [9] Counting platelets in platelet concentrates on hematology analyzers: a multicenter comparative study
    van der Meer, Pieter F.
    Dijkstra-Tiekstra, Margriet J.
    Mahon, Anne
    de Wildt-Eggen, Janny
    [J]. TRANSFUSION, 2009, 49 (01) : 81 - 90
  • [10] HEMATOLOGY ANALYZERS
    SCHOENTAG, RA