Pyrene-Based "Turn-Off" Probe with Broad Detection Range for Cu2+, Pb2+ and Hg2+ Ions

被引:31
|
作者
Merz, Viktor [1 ]
Merz, Julia [2 ]
Kirchner, Maximilian [1 ]
Lenhart, Julian [1 ]
Marder, Todd B. [2 ]
Krueger, Anke [1 ,3 ]
机构
[1] Julius Maximilians Univ Wurzburg, Inst Organ Chem, D-97074 Wurzburg, Germany
[2] Julius Maximilians Univ Wurzburg, Inst Inorgan Chem, D-97074 Wurzburg, Germany
[3] Julius Maximilians Univ Wurzburg, Wilhelm Conrad Rontgen Ctr Complex Mat Res RCCM, D-97074 Wurzburg, Germany
关键词
Fluorescence spectroscopy; heavy metals; luminescence; probes; pyrene; VINEYARD SPRAYERS LUNG; HEAVY-METALS; FLUORESCENT CHEMOSENSOR; JOB PLOT; COPPER; MECHANISMS; EFFICIENT; REMOVAL; SENSOR; CLICK;
D O I
10.1002/chem.202100594
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Detection of metals in different environments with high selectivity and specificity is one of the prerequisites of the fight against environmental pollution with these elements. Pyrenes are well suited for the fluorescence sensing in different media. The applied sensing principle typically relies on the formation of intra- and intermolecular excimers, which is however limiting the sensitivity range due to masking of e. g. quenching effects by the excimer emission. Herein we report a highly selective, structurally rigid chemical sensor based on the monomer fluorescence of pyrene moieties bearing triazole groups. This sensor can quantitatively detect Cu2+, Pb2+ and Hg2+ in organic solvents over a broad concentrations range, even in the presence of ubiquitous ions such as Na+, K+, Ca2+ and Mg2+. The strongly emissive sensor's fluorescence with a long lifetime of 165 ns is quenched by a 1 : 1 complex formation upon addition of metal ions in acetonitrile. Upon addition of a tenfold excess of the metal ion to the sensor, agglomerates with a diameter of about 3 nm are formed. Due to complex interactions in the system, conventional linear correlations are not observed for all concentrations. Therefore, a critical comparison between the conventional Job plot interpretation, the method of Benesi-Hildebrand, and a non-linear fit is presented. The reported system enables the specific and robust sensing of medically and environmentally relevant ions in the health-relevant nM range and could be used e. g. for the monitoring of the respective ions in waste streams.
引用
收藏
页码:8118 / 8126
页数:9
相关论文
共 50 条
  • [1] AIE active turn-off fluorescent probe for the detection of Cu2+ ions
    Pannipara, Mehboobali
    Al-Sehemi, Abdullah G.
    Kalam, Abul
    Asiri, Abdullah M.
    Arshad, Muhammad Nadeem
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2017, 183 : 84 - 89
  • [2] Dihydroquinazolinone based "turn-off" fluorescence sensor for detection of Cu2+ ions
    Borase, Pravin N.
    Thale, Pranila B.
    Shankarling, Ganapati S.
    [J]. DYES AND PIGMENTS, 2016, 134 : 276 - 284
  • [3] Ester appended organosilatranes: Paradigm for the detection of Cu2+, Pb2+ and Hg2+ ion
    Singh, Gurjaspreet
    Sanchita
    Singh, Akshpreet
    Sharma, Geetika
    Kalra, Pooja
    Satija, Pinky
    Diksha
    Soni, Sajeev
    Verma, Vikas
    [J]. INORGANICA CHIMICA ACTA, 2019, 490 : 85 - 92
  • [4] Gold nanoflowers based colorimetric detection of Hg2+ and Pb2+ ions
    Nalawade, Pradnya
    Kapoor, Sudhir
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2013, 116 : 132 - 135
  • [5] Application of Humic Sorbents for Pb2+, Cu2+ and Hg2+ ions preconcentration from aqueous solutions
    Vetrova, Olga V.
    Konovalov, Konstantin B.
    Gavrilenko, Mikhail A.
    [J]. XV INTERNATIONAL SCIENTIFIC CONFERENCE CHEMISTRY AND CHEMICAL ENGINEERING IN XXI CENTURY DEDICATED TO PROFESSOR L.P. KULYOV, 2014, 10 : 120 - 126
  • [6] USE OF HUMIC SORBENTS FOR Pb2+, Cu2+, Hg2+ IONS PRECONCENTRATION FROM AQUEOUS SOLUTIONS
    Vetrova, O. V.
    Konovalov, K. B.
    Gavrilenko, M. A.
    [J]. IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII KHIMIYA I KHIMICHESKAYA TEKHNOLOGIYA, 2014, 57 (11): : 27 - +
  • [7] A dansyl-based fluorescent probe for turn-off and turn-on detection of Hg2+ in a full water system
    Chunming Sha
    Zhengkun Li
    Shenzhou Lu
    Xiaolong Hu
    Dongmei Xu
    [J]. Research on Chemical Intermediates, 2022, 48 : 5227 - 5241
  • [8] A dansyl-based fluorescent probe for turn-off and turn-on detection of Hg2+ in a full water system
    Sha, Chunming
    Li, Zhengkun
    Lu, Shenzhou
    Hu, Xiaolong
    Xu, Dongmei
    [J]. RESEARCH ON CHEMICAL INTERMEDIATES, 2022, 48 (12) : 5227 - 5241
  • [9] A novel pyrene-based "off-on" fluorescent probe with high selectivity and sensitivity for Hg2+
    Liang, Qingxiang
    Zhou, Wu
    Wu, Aibin
    Shu, Wenming
    Yu, Weichu
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2023, 70 (10) : 1937 - 1943
  • [10] An efficient naphthalimide based receptor for selective detection of Hg2+ and Pb2+ ions
    Patil, Pramod D. Jawale
    Wagalgave, Sopan M.
    Al Kobaisi, Mohammad
    Birajdar, Shailesh S.
    Bhosale, Rajesh S.
    Ingle, Rajita D.
    Pawar, Rajendra P.
    Bhosale, Sheshanath, V
    Bhosale, Sidhanath, V
    [J]. INDIAN JOURNAL OF CHEMISTRY SECTION B-ORGANIC CHEMISTRY INCLUDING MEDICINAL CHEMISTRY, 2021, 60 (10): : 1353 - 1361