Macrofouling in the cooling water conduits of a coastal power station

被引:0
|
作者
Thiyagarajan, V [1 ]
Venugopalan, VP [1 ]
Subramoniam, T [1 ]
Nair, KVK [1 ]
机构
[1] Univ Madras, Dept Zool, Madras 600025, Tamil Nadu, India
来源
INDIAN JOURNAL OF MARINE SCIENCES | 1997年 / 26卷 / 03期
关键词
D O I
暂无
中图分类号
P7 [海洋学];
学科分类号
0707 ;
摘要
Macrofouling incidence at six different locations experiencing different environmental conditions in the cooling conduits of the Madras Atomic Power Station (MAPS) was studied. Samples were analyzed for biomass and species abundance. Fouling biomass was significantly (t=3.95, P=0.0016) higher on concrete surface than on carbon steel surface. Flow velocity, temperature and substratum type were the main factors which determined community structure in different sections of the cooling conduits. These factors as well as the fouling control regime adopted in cooling systems make fouling more intense in some places than in others.
引用
收藏
页码:305 / 308
页数:4
相关论文
共 50 条
  • [1] Chlorination and mussel control in the cooling conduits of a tropical coastal power station
    Rajagopal, S
    Nair, KVK
    Azariah, J
    vanderVelde, G
    Jenner, HA
    MARINE ENVIRONMENTAL RESEARCH, 1996, 41 (02) : 201 - 221
  • [2] POWER STATION COOLING WATER IN ESTUARIES
    JARMAN, RT
    DETURVIL.CM
    DOCK & HARBOUR AUTHORITY, 1968, 49 (572): : 66 - &
  • [3] Vortex Pairs and Power Station Cooling Water
    Macqueen, J. F.
    ADVANCES IN WATER RESOURCES, 1978, 1 (03) : 169 - 174
  • [4] COOLING WATER INTAKES AT WYLFA POWER STATION
    CHAPMAN, EJK
    GIBB, FR
    PUGH, CE
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS, 1969, 42 (FEB): : 193 - &
  • [5] REMOTE-SENSING OBSERVATIONS AND ANALYSES OF COOLING WATER DISCHARGES FROM A COASTAL POWER-STATION
    DAVIES, PA
    MOFOR, LA
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 1993, 14 (02) : 253 - 273
  • [6] Review on Water Distribution of Cooling Tower in Power Station
    Zhang Huichao
    Fang Lei
    Guang Hao
    Niu Ying
    2018 ASIA CONFERENCE ON ENERGY AND ENVIRONMENT ENGINEERING (ACEEE 18), 2018, 133
  • [7] DISCUSSION OF COOLING WATER INTAKES AT WYLFA POWER STATION
    WILLIAMS, M
    HAIGH, IP
    DAWSON, O
    ANDREWS, PAG
    CROSTHWA.CD
    SEDDON, BT
    FITZHERB.WA
    BISHOP, RW
    SHILSTON, AW
    PATERSON, AC
    CHAPMAN
    GIBB
    PUGH
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS, 1969, 44 (NOV): : 247 - &
  • [8] Concentration of contaminants discharged with power station cooling water
    Macqueen, J. F.
    ADVANCES IN WATER RESOURCES, 1980, 3 (04) : 165 - 172
  • [9] Barking Reach Power Station cooling water system
    Evans, JF
    Hodgkins, DJ
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-CIVIL ENGINEERING, 1997, 120 (01) : 15 - 26
  • [10] Macrofouling communities in the cooling system of the Vladivostok heat and power plant
    Moshchenko A.V.