Characterization of Nylon-12 as a water-equivalent solid phantom material for dosimetric measurements in therapeutic photon and electron beams

被引:4
|
作者
Ade, Nicholas [1 ]
van Eeden, D. [1 ]
du Plessis, F. C. P. [1 ]
机构
[1] Univ Free State, Med Phys Dept, POB 339, ZA-9300 Bloemfontein, South Africa
基金
英国医学研究理事会;
关键词
Nylon-12; Water-equivalence; Gafchromic film; Dosimetry; Photons; Electrons; EFFECTIVE ATOMIC NUMBERS; EBT FILM; ATTENUATION; ACCURACY; RADIOTHERAPY; PROSTHESIS; RANGE; MODEL;
D O I
10.1016/j.apradiso.2019.108919
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The tissue- or water-equivalence of dosimetry phantoms used as substitutes for water is essential for absorbed dose measurements in radiotherapy. At our institution, a heterogeneous pelvic phantom that consists of stacked Nylon-12 layers has recently been manufactured for Gafchromic film dosimetry. However, data on the use of Nylon as tissue-mimicking media for dosimetric applications are scarce. This study characterizes the water-equivalence of Nylon-12 for dosimetric measurements in therapeutic photon and electron beams. Employing an Elekta Synergy and SL25 linear accelerator (Linac), photon beam transmission measurements for 6 MV and 15 MV, acquired in narrow beam geometry with a 0.6 cm(3) Farmer-type ion chamber showed that the mass attenuation coefficient mu(m) of Nylon-12 agrees with the values of water, water-equivalent RW3 and Perspex phantom materials within 3%. For 6 MV, the mu(m) values were 0.0477 +/- 0.002 cm(2)/g, 0.0490 +/- 0.003 cm(2)/g, 0.0482 +/- 1 0.001 cm(2)/g and 0.0479 +/- 0.002cm(2)/g for Nylon-12, water, RW3, and Perspex, respectively. Differences within 2% were attained between depth dose data measured in Nylon-12 slabs with Gafchromic EBT3 films and in water with a Roos ion chamber for 10 x 10 cm(2) 6, 12 and 20 MeV electron beams produced by the Elekta Synergy and SL25 Linacs. Also, a good agreement within 2% was obtained between percent depth doses computed by DOSXYZnrc Monte Carlo simulations in water, Nylon-12 and RW3 materials for photon spectra between 250 kV and 15 MV. The discrepancies between the ratios of average, restricted stopping powers of Nylon to air and water to air for photon spectra ranging from 2 to 45 MV are typically within 1% signifying that Nylon and water have equivalent stopping power characteristics. This study highlights that Nylon-12 can be used as a tissue-mimicking phantom material for dosimetric measurements in clinical megavoltage photon and electron beams as it exhibits good water-equivalence.
引用
收藏
页数:8
相关论文
共 17 条
  • [1] Detailed characterization of the water-equivalent material virtual water in high-energy photon and electron beams
    McEwen, M
    MEDICAL PHYSICS, 2005, 32 (06) : 2003 - 2004
  • [2] HOW WATER EQUIVALENT ARE WATER-EQUIVALENT SOLID MATERIALS FOR OUTPUT CALIBRATION OF PHOTON AND ELECTRON-BEAMS
    TELLO, VM
    TAILOR, RC
    HANSON, WF
    MEDICAL PHYSICS, 1995, 22 (07) : 1177 - 1189
  • [3] Ice as a water-equivalent solid medium for brachytherapy dosimetric measurements
    Song, Haijun
    Chen, Zhe
    Yue, Ning
    Wu, Qingrong
    Yin, Fang-fang
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2009, 48 (02) : 145 - 151
  • [4] Ice as a water-equivalent solid medium for brachytherapy dosimetric measurements
    Haijun Song
    Zhe Chen
    Ning Yue
    Qingrong Wu
    Fang-fang Yin
    Radiation and Environmental Biophysics, 2009, 48 : 145 - 151
  • [5] EVALUATION OF WATER-EQUIVALENT PLASTICS AS PHANTOM MATERIAL FOR ELECTRON-BEAM DOSIMETRY
    THOMADSEN, B
    CONSTANTINOU, C
    HO, A
    MEDICAL PHYSICS, 1995, 22 (03) : 291 - 296
  • [6] Quasi water-equivalent detectors for photon beams that present lateral electron disequilibrium
    Piermattei, A
    Azario, L
    Fidanzio, A
    Arcovito, G
    PHYSICA MEDICA, 1998, 14 (01) : 9 - 17
  • [7] Characterization of the water-equivalent material WTe for use in electron beam dosimetry
    McEwen, MR
    DuSautoy, AR
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (13): : 1885 - 1893
  • [8] Characterization of the phantom material Virtual Water™ in high-energy photon and electron beams
    McEwen, MR
    Niven, D
    MEDICAL PHYSICS, 2006, 33 (04) : 876 - 887
  • [9] MEASUREMENT OF IONIZATION IN WATER, POLYSTYRENE AND A SOLID WATER PHANTOM MATERIAL FOR ELECTRON-BEAMS
    THWAITES, DI
    PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (01): : 41 - 53
  • [10] Dosimetric Properties of a New Solid Water High Equivalency Phantom for High-Energy Photon Beams
    Araki, F.
    Ohno, T.
    Onitsuka, R.
    Shimohigashi, Y.
    MEDICAL PHYSICS, 2015, 42 (06) : 3410 - 3410