Comparison of diagnostic values between ultrasound elastography and ultrasound-guided thyroid nodular puncture in thyroid nodules

被引:9
|
作者
Pan, Xiaojie [1 ]
Wang, Lei [1 ]
机构
[1] Liaocheng Peoples Hosp, Dept Ultrasound, 67 Dongchang West Rd, Liaocheng 252000, Shandong, Peoples R China
关键词
ultrasound elastography; ultrasound-guided fine needle puncture biopsy; thyroid nodule; diagnostic values; ASSOCIATION GUIDELINES; RISK STRATIFICATION; REAL-TIME; ULTRASONOGRAPHY; MALIGNANCY; CYTOLOGY; CANCER; BENIGN; SYSTEM; PERFORMANCE;
D O I
10.3892/ol.2018.9257
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Diagnostic value between ultrasound elastography and ultrasound-guided fine needle puncture biopsy in thyroid nodules was compared to provide reference for the selection of thyroid nodule (TN) diagnostic mode. A total of 194 patients with TN, admitted from June 2014 to June 2015, were selected to be treated with ultrasound elastography and ultrasound-guided fine needle puncture biopsy. The ultrasonic elasticity score and results of ultrasound-guided TN puncture were compared with diagnostic results of surgical or ultrasound follow-up for 12 months, and the sensitivity, specificity and accuracy of differentiating and diagnosing TN of the two methods were calculated to compare the clinical diagnostic values. A total of 194 patients were diagnosed with TN 217, including 129 benign and 88 malignant lesions. All the nodules were obtained by effective ultrasound elastography and ultrasound-guided fine needle puncture cytological pathological specimens, and it was diagnosed by ultrasound elastography that there were 75 benign nodules and 142 malignant nodules. It was diagnosed by ultrasound-guided fine needle puncture that there were 112 benign, 78 malignant and 27 uncertain nodules. The specificity and accuracy of ultrasound-guided fine needle puncture in the diagnosis of TN were higher than that of ultrasound elastography and the differences were statistically significant (P<0.05), while there was no statistically significant difference between the sensitivity of ultrasound elastography and ultrasound-guided fine needle puncture biopsy in the diagnosis of TN (P>0.05). Ultrasound elastography in the diagnosis of TN has a low specificity and the diagnosis of ultrasound-guided fine needle puncture biopsy may have uncertain results. There are some defects in the two diagnostic schemes and their combined application can complement each other's advantages and improve the early diagnostic efficiency of TN.
引用
收藏
页码:5209 / 5213
页数:5
相关论文
共 50 条
  • [1] The Diagnostic Values of Ultrasound and Ultrasound-Guided Fine Needle Aspiration in Subcentimeter-Sized Thyroid Nodules
    Hee Jung Moon
    Eunju Son
    Eun-Kyung Kim
    Jung Hyun Yoon
    Jin Young Kwak
    [J]. Annals of Surgical Oncology, 2012, 19 : 52 - 59
  • [2] The Diagnostic Values of Ultrasound and Ultrasound-Guided Fine Needle Aspiration in Subcentimeter-Sized Thyroid Nodules
    Moon, Hee Jung
    Son, Eunju
    Kim, Eun-Kyung
    Yoon, Jung Hyun
    Kwak, Jin Young
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2012, 19 (01) : 52 - 59
  • [3] Comparison of Ultrasound-Guided FNA with CNB in the Evaluation of Thyroid Nodules
    Laziuk, K.
    Malone, W.
    Watt, A.
    Jennings, T. A.
    [J]. MODERN PATHOLOGY, 2011, 24 : 97A - 97A
  • [4] Comparison of Ultrasound-Guided FNA with CNB in the Evaluation of Thyroid Nodules
    Laziuk, K.
    Malone, W.
    Watt, A.
    Jennings, T. A.
    [J]. LABORATORY INVESTIGATION, 2011, 91 : 97A - 97A
  • [5] Ultrasound elastography in the diagnostic evaluation of indeterminate thyroid nodules
    Abdelrahman, Sherif Fathy
    Ali, Fatma Hassan
    Khalil, Mohsen El-Sayed
    El Masry, Manal Roshdy
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2015, 46 (03): : 639 - 648
  • [6] Comparison analysis between conventional ultrasonography and ultrasound elastography of thyroid nodules
    Cong Shuzhen
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (08) : 1806 - 1811
  • [7] Comparison between ultrasound-guided percutaneous radiofrequency and microwave ablation in benign thyroid nodules
    Hu, Ke
    Wu, Jingjing
    Dong, Yi
    Yan, Zhiping
    Lu, Zhiqiang
    Liu, Lingxiao
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (07) : 1535 - 1540
  • [8] Ultrasound elastography in the evaluation of thyroid nodules for thyroid cancer
    Carneiro-Pla, Denise
    [J]. CURRENT OPINION IN ONCOLOGY, 2013, 25 (01) : 1 - 5
  • [9] Ultrasound-guided fine needle aspiration cytology and ultrasound examination of thyroid nodules in the UAE: A comparison
    Al-Salam, Suhail
    Sharma, Charu
    Abu Sa'a, Maysam T.
    Afandi, Bachar
    Aldahmani, Khaled M.
    Al Dhaheri, Alia
    Yahya, Hayat
    Al Naqbi, Duha
    Al Zuraiqi, Esraa
    Mohamed, Baraa Kamal
    Almansoori, Shamsa Ahmed
    Al Zaabi, Meera
    Al Derei, Aysha
    Al Shamsi, Amal
    Al Kaabi, Juma
    [J]. PLOS ONE, 2021, 16 (04):
  • [10] Ultrasound-Guided Biopsy of the Thyroid: A Comparison of Technique With Respect to Diagnostic Accuracy
    Schoedel, Karen E.
    Tublin, Mitchell E.
    Pealer, Karen
    Ohori, N. Paul
    [J]. DIAGNOSTIC CYTOPATHOLOGY, 2008, 36 (11) : 787 - 789