Vascular capsule for telemetric monitoring of blood pressure

被引:5
|
作者
Schmitz-Rode, T
Schnakenberg, U
Pfeffer, JG
Piroth, W
Bögel, GV
Mokwa, W
Günther, RW
机构
[1] Fraunhofer Inst Microelect Circuits & Syst, D-4100 Duisburg, Germany
[2] Rhein Westfal TH Aachen, Inst Mat Elect Engn, Aachen, Germany
[3] Rhein Westfal TH Aachen, Rhein Westfal TH Aachen, Radiol Diagnost Klin, Univ Klinikum, D-52057 Aachen, Germany
关键词
microelectromechanical system; transponder technology; pressure sensor; non-invasive blood pressure monitoring;
D O I
10.1055/s-2003-37232
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Development and experimental evaluation of an intravascular monitoring system for telemetric measurement of blood pressure and heart rate. Materials and Methods: The monitoring system consists of an implantable silicone capsule (diameter 2.3 mm), containing a dedicated microchip with pressure sensors and signal-processing circuits as well as an antenna for wireless data and energy transfer using 6.78 MHz transponder technology. Three self-expanding legs at one end of the capsule served as a mechanism to lock the capsule at an arterial branch. A flow model, driven by a ventricular assist system, was used for testing and optimizing the implantation equipment, for checking the anchoring mechanism and for ensuring transmission of the measured pressure to the readout unit. In-vivo experiments were performed in 8 minipigs (weight 25 to 30 kg), with three capsules placed in each minipig via the femoral artery using a dedicated 8-F sheath/pusher system. Follow-up was by CT angiography for up to 6 months after implantation. Results: Flow model tests revealed a maximum deviation of pressure and heart rate measurements of 5% from the reference measurements. Signal transmission was reliable over a distance of 3 to 4 cm. Fluoroscopically guided in-vivo implantation of the capsules was simple and straightforward. In arteries with a diameter of 5 to 6 mm, the capsules were permanently fixed with one or two legs interlocked in side branches and without occlusion within 6 months. Three capsules developed a small non-occlusive appositional thrombus attached to the downstream (leg) part of the capsule. Conclusion: Our in-vitro and in-vivo experiments demonstrate the feasibility of wireless transmission from a capsule with a sufficient resolution of the sensor output signals to determine blood pressure and pulse rate. As long as the vessel diameter is wide enough, arterial fixation of the capsule does not induce thrombotic occlusion of the parent artery. With respect to future clinical applications, further refinements of the transmission technology are needed to extend the transmission distance between capsule and reader antenna. The technology of intelligent implants has further implications, such as monitoring of other physiological parameters, and the,design of a control loop, which may be used for therapeutic feedback.
引用
收藏
页码:282 / 286
页数:5
相关论文
共 50 条
  • [1] Telemetric monitoring of blood pressure and body weight during pregnancy
    Middeke, M.
    Koehler, F.
    Schweizer, T.
    Dudenhausen, J. W.
    [J]. DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2007, 132 (09) : 437 - 441
  • [2] Telemetric blood pressure monitoring in hypertensive patients with renal insufficiency
    Burnier, M.
    Bock, A.
    [J]. SWISS MEDICAL WEEKLY, 2009, 139 (45-46) : 10S - 10S
  • [3] Effects of telemetric blood pressure monitoring on antihypertensive management with irbesartan
    Schulz, E.
    Neumann, L.
    Wolf, A.
    Fischer, N.
    Korth, U.
    Weber, M.
    [J]. JOURNAL OF HYPERTENSION, 2007, 25 : S8 - S8
  • [4] Telemetric monitoring of blood flow and pressure in a chronic lamb model
    Fujji, Yasuhiro
    Centola, Luca
    Kinouchi, Katsushi
    Zhu, Liqun
    Pitsillides, Koullis
    Ferrier, William
    Talken, Linda
    Nasirov, Teimour
    Reinhartz, Olaf
    Riemer, R. Kirk
    [J]. FASEB JOURNAL, 2014, 28 (01):
  • [5] TELEMETRIC MONITORING OF CSF PRESSURE
    ALLEN, KL
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1972, 35 (06): : 922 - 922
  • [6] Telemetric monitoring of blood pressure in freely moving mice: a preliminary study
    Kramer, K
    Voss, HP
    Grimbergen, JA
    Mills, PA
    Huetteman, D
    Zwiers, L
    Brockway, B
    [J]. LABORATORY ANIMALS, 2000, 34 (03) : 272 - 280
  • [7] Telemetric intracranial pressure monitoring in children
    Sarah Hornshøj Pedersen
    Nicolas Hernandez Norager
    Alexander Lilja-Cyron
    Marianne Juhler
    [J]. Child's Nervous System, 2020, 36 : 49 - 58
  • [8] Telemetric intracranial pressure monitoring in children
    Pedersen, Sarah Hornshoj
    Norager, Nicolas Hernandez
    Lilja-Cyron, Alexander
    Juhler, Marianne
    [J]. CHILDS NERVOUS SYSTEM, 2020, 36 (01) : 49 - 58
  • [9] Telemetric system for the monitoring of plantar pressure
    Blanco, Sandra M. R.
    Angelo Zamudio, D.
    Jaime Delgado, S.
    [J]. IV LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING 2007, BIOENGINEERING SOLUTIONS FOR LATIN AMERICA HEALTH, VOLS 1 AND 2, 2008, 18 (1,2): : 686 - 689
  • [10] Telemetric intracavernosal and intraspongiosal pressure monitoring
    Shamloul, Rany
    [J]. JOURNAL OF SEXUAL MEDICINE, 2008, 5 (10): : 2246 - 2252