摘要
In this paper an approach based on wavelet transform to access the on line Partial Discharge (PD) signal using MATLAB interface with Digital Storage Oscilloscope (DSO) is proposed. The noisy signal is collected and fed to computer through DSO to de-noise this using wavelet threshold technique by selecting the optimal wavelet base. From the results it shows that the de-noising performance is satisfactory, even though the sampling rate of DSO is less, which is the main advantage of this method.
引用
收藏
页码:382 / 384
页数:3
相关论文
共 50 条
  • [1] On-line Monitoring System for Transformer Partial Discharge
    Liu, Guangya
    Kang, Lu
    Peng, Weina
    [J]. SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, PTS 1-4, 2013, 303-306 : 464 - 467
  • [2] On-line monitoring partial discharge in electrical equipments
    Zhu, DH
    Tan, KX
    Wang, CC
    [J]. JOINT CONFERENCE OF 96' AICDEI / 4T-JCCEID, 1996, : 329 - 332
  • [3] Partial Discharge On-Line Monitoring of Outdoor Insulators
    Shurrab, Ibrahim Y.
    El-Hag, Ayman
    Assaleh, Khaled
    Ghunem, Refat
    [J]. CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 391 - 394
  • [4] The Design of Multiplexer for on-line Partial Discharge Monitoring System
    Yang, Yuan
    Bi, Jiangang
    Gong, Yanpeng
    Yang, Ning
    [J]. MATERIALS PROCESSING AND MANUFACTURING III, PTS 1-4, 2013, 753-755 : 2227 - 2231
  • [5] Continuous on-line partial discharge monitoring of power generators
    Kheirmand, A
    Leijon, M
    [J]. IEEE 1996 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I & II, 1996, : 496 - 499
  • [6] Partial discharge on-line monitoring system based on FPGA
    Cheng, YH
    Hu, XS
    Chen, XL
    Li, PZ
    [J]. PROCEEDINGS OF THE 2005 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, VOLS, 1-3, 2005, : 486 - 489
  • [7] On-line Partial Discharge Monitoring System for Distribution Networks
    Mulroy, Patrick
    Hurtado, Aritz
    Badetz, David
    [J]. PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 542 - 545
  • [8] EXPERIENCE WITH ON-LINE PARTIAL DISCHARGE MONITORING OF GENERATORS AND MOTORS
    Yasuma, Hajime
    Stone, Greg
    [J]. ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 206 - 206
  • [9] GIT partial discharge UHF on-line monitoring system
    Zhang, Xiao-Xing
    Wang, Zhen
    Tang, Ju
    Liu, Lei
    Wei, Yan
    [J]. Gaodianya Jishu/High Voltage Engineering, 2010, 36 (07): : 1692 - 1697
  • [10] Development of a New On-Line Partial Discharge Monitoring System
    Ohki, Yoshimichi
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2020, 36 (04) : 67 - 70