Experimental study on the fire protection properties of PVC sheath for old and new cables

被引:60
|
作者
Xie, Qiyuan [1 ]
Zhang, Heping [1 ]
Tong, Lin [1 ]
机构
[1] USTC, State Key Lab Fire Sci, Hefei 230027, Peoples R China
基金
中国博士后科学基金;
关键词
Fire protection property; Old cable; Atmosphere; TG-FTIR; MCC; TG-FTIR ANALYSIS; THERMAL-DEGRADATION; PYROLYSIS;
D O I
10.1016/j.jhazmat.2010.03.015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of the present study is to analyze the fire protection properties of old and new cables through TG, FTIR and MCC experiments. The results show that the mass loss of old cable sheath is clearly larger than the new one when the temperature is higher than 550 K in air or nitrogen atmosphere. It suggests that the old cable sheath starts to pyrolyze generally at the same temperature based on the analysis of the onset temperatures of mass loss. The results also show that there is a main peak DTG for the old and new cable sheath under each condition. However, the main peak DTG of old cable sheath is larger than that of the new cable sheath, especially in air atmosphere. The FTIR experiments show that the HCI is released by the new cable later but more quickly than the old cable. The MCC experiments suggest that compared with the new one, the peak heat release rate is larger for the old cable. It illustrates that the old cable sheath generally pyrolyzes and combusts more strongly and completely than the new one. Namely, the fire protection properties of the old cable in old buildings are relatively weak. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:373 / 381
页数:9
相关论文
共 50 条
  • [1] Experimental study of epoxy coatings for fire protection of bridge cables
    Tolstrup, Jonas
    Giuliani, Luisa
    Narasimhan, Harikrishna
    Jensen, Jakob Laigaard
    Jomaas, Grunde
    ce/papers, 2019, 3 (3-4) : 653 - 658
  • [2] Thermal degradation kinetics study of polyvinyl chloride (PVC) sheath for new and aged cables
    Wang, Zhi
    Xie, Tian
    Ning, Xiaoyao
    Liu, Yuchuan
    Wang, Jian
    WASTE MANAGEMENT, 2019, 99 : 146 - 153
  • [3] Experiment study on fire performance of PVC sheath electrical cables exposed to high-level heat flux
    Shu Zhongjun
    Feng Junfeng
    Li Peng
    Chen Nan
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 1448 - 1450
  • [4] PROPERTIES OF PVC COMPOUNDS WITH IMPROVED FIRE PERFORMANCE FOR ELECTRICAL CABLES
    MATHESON, AF
    CHARGE, R
    CORNELIUSSEN, T
    FIRE SAFETY JOURNAL, 1992, 19 (01) : 55 - 72
  • [5] NEW TYPES OF FIRE RETARDANT MATERIALS AND THEIR APPLICATION TO FIRE PROTECTION OF CABLES.
    Yabuki, T.
    Koide, Y.
    Kaide, T.
    Ichikawa, K.
    Takada, M.
    Dainichi-Nippon Cables Review, 1976, (61): : 56 - 71
  • [6] Experimental study on burn through properties of PVC membrane room under fire
    Chai, Guoqiang
    Zhu, Guoqing
    Zhou, Jinju
    Gao, Yunji
    Zhou, Ying
    Wang, Yang
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 26
  • [7] Study on the thermal degradation behaviors of the sheath and insulation materials of FR-PVC cables
    Zhang, Xiang
    Zhang, Fan
    ADVANCES IN CHEMICAL ENGINEERING II, PTS 1-4, 2012, 550-553 : 914 - 918
  • [8] An experimental study about the fire resistance of low voltage cables
    Guastavino, F.
    Coletti, G.
    Ratto, A.
    Torello, E.
    Michelato, P.
    Celentano, M.
    Zucchelli, A.
    CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2006, : 174 - +
  • [9] Experimental study of the interaction between the water mists and PVC fire
    Zhang Yongfeng
    Fang Yudong
    Xin, Huang
    Jin Xiang
    Jun, Qin
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2007, 85 (B1) : 39 - 44
  • [10] An Experimental Study on the Contribution of Fire Retardant Coating to the Fire Protection of Concrete
    Cao, Weijun
    Ou, Manli
    Liu, Fangcheng
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 2660 - 2664