A new retrospective, multi-evidence veterinary drug screening method using drift tube ion mobility mass spectrometry

被引:14
|
作者
Xu, Zhenzhen [1 ,2 ]
Li, Jianzhong [3 ]
Chen, Ailiang [1 ,2 ]
Ma, Xin [3 ]
Yang, Shuming [1 ,2 ]
机构
[1] Chinese Acad Agr Sci, Inst Qual Standard & Testing Technol Agroprod, Beijing 100081, Peoples R China
[2] Minist Agr, Key Lab Agrofood Safety & Qual, Beijing 100081, Peoples R China
[3] Agilent Technol, Beijing 100102, Peoples R China
关键词
COLLISION CROSS-SECTION; MS; INSTRUMENTATION; FRAGMENTATION; VALIDATION; RESIDUES;
D O I
10.1002/rcm.8154
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleThe retrospectivity (the ability to retrospect to a previously unknown compound in raw data) is very meaningful for food safety and risk assessment when facing new emerging drugs. Accurate mass and retention time based screening may lead to false positive and false negative results so a new retrospective, reliable platform is desirable. MethodsDifferent concentration levels of standards with and without matrix were analyzed using ion mobility (IM)-quadrupole-time-of-flight (QTOF) mass spectrometry to collect retrospective accurate mass, retention time, drift time and tandem mass spectrometry (MS/MS) evidence for identification in a single experiment. The isomer separation ability of IM and the four-dimensional (4D) feature abundance quantification abilities were evaluated for veterinary drugs for the first time. ResultsThe sensitivity of the IM-QTOF workflow was obviously higher than that of the traditional database searching algorithm [find by formula (FbF) function] for QTOF. In addition, the IM-QTOF workflow contained most of the results from FbF and removed the false positive results. Some isomers were separated by IM and the 4D feature abundance quantitation removed interferences with similar accurate masses and showed good linearity. ConclusionsA new retrospective, multi-evidence platform was built for veterinary drug screening in a single experiment. The sensitivity was significantly improved and the data can be used for quantification. The platform showed its potential to be used for food safety and risk assessment.
引用
收藏
页码:1141 / 1148
页数:8
相关论文
共 50 条
  • [1] Comparison of CCS Values Determined by Traveling Wave Ion Mobility Mass Spectrometry and Drift Tube Ion Mobility Mass Spectrometry
    Hinnenkamp, Vanessa
    Klein, Julia
    Meckelmann, Sven W.
    Balsaa, Peter
    Schmidt, Torsten C.
    Schmitz, Oliver J.
    ANALYTICAL CHEMISTRY, 2018, 90 (20) : 12042 - 12050
  • [2] Separation of phosphorothioated oligonucleotide diastereomers using multiplexed drift tube ion mobility mass spectrometry
    Demelenne, Alice
    Nys, Gwenael
    Nix, Cindy
    Fjeldsted, John C.
    Crommen, Jacques
    Fillet, Marianne
    ANALYTICA CHIMICA ACTA, 2022, 1191
  • [3] High-throughput screening and quantitation of guanidino and ureido compounds using liquid chromatography-drift tube ion mobility spectrometry-mass spectrometry
    Fan, Ruo-Jing
    Zhang, Fang
    Chen, Xiu-Ping
    Qi, Wan-Shu
    Guan, Qing
    Sun, Tuan-Qi
    Guo, Yin-Long
    ANALYTICA CHIMICA ACTA, 2017, 961 : 82 - 90
  • [4] Atmospheric Pressure Drift Tube Ion Mobility Spectrometry Coupled with Two-Dimensional Tandem Mass Spectrometry
    Schrader, Robert L.
    Marsh, Brett M.
    Cooks, R. Graham
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2021, 32 (08) : 2105 - 2109
  • [5] Liquid chromatography–drift tube ion mobility–mass spectrometry as a new challenging tool for the separation and characterization of silymarin flavonolignans
    Marie Fenclova
    Milena Stranska-Zachariasova
    Frantisek Benes
    Alena Novakova
    Petra Jonatova
    Vladimir Kren
    Libor Vitek
    Jana Hajslova
    Analytical and Bioanalytical Chemistry, 2020, 412 : 819 - 832
  • [6] Resolving Structural Isomers of Monosaccharide Methyl Glycosides Using Drift Tube and Traveling Wave Ion Mobility Mass Spectrometry
    Li, Hongli
    Giles, Kevin
    Bendiak, Brad
    Kaplan, Kimberly
    Siems, William F.
    Hill, Herbert H., Jr.
    ANALYTICAL CHEMISTRY, 2012, 84 (07) : 3231 - 3239
  • [7] Coupling IR-MALDESI with Drift Tube Ion Mobility-Mass Spectrometry for High-Throughput Screening and Imaging Applications
    Ekelof, Mans
    Dodds, James
    Khodjaniyazova, Sitora
    Garrard, Kenneth P.
    Baker, Erin S.
    Muddiman, David C.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2020, 31 (03) : 642 - 650
  • [8] Coupling laser ablation/desorption electrospray ionization to atmospheric pressure drift tube ion mobility spectrometry for the screening of antimalarial drug quality
    Harris, Glenn A.
    Graf, Stephan
    Knochenmuss, Richard
    Fernandez, Facundo M.
    ANALYST, 2012, 137 (13) : 3039 - 3044
  • [9] An Interlaboratory Evaluation of Drift Tube Ion Mobility-Mass Spectrometry Collision Cross Section Measurements
    Stow, Sarah M.
    Causon, Tim J.
    Zheng, Xueyun
    Kurulugama, Ruwan T.
    Mairinger, Teresa
    May, Jody C.
    Rennie, Emma E.
    Baker, Erin S.
    Smith, Richard D.
    McLean, John A.
    Hann, Stephan
    Fjeldsted, John C.
    ANALYTICAL CHEMISTRY, 2017, 89 (17) : 9048 - 9055
  • [10] An economical setup for atmospheric pressure chemical ionization drift tube ion-mobility mass spectrometry
    Raju, Chamarthi Maheswar
    Buchowiecki, Krzysztof
    Urban, Pawel L.
    ANALYTICA CHIMICA ACTA, 2023, 1268