On the environmental suitability of high- and low-enthalpy geothermal systems

被引:57
|
作者
Martin-Gamboa, Mario [1 ]
Iribarren, Diego [1 ]
Dufour, Javier [1 ,2 ]
机构
[1] Inst IMDEA Energia, Syst Anal Unit, Mostoles 28935, Spain
[2] Rey Juan Carlos Univ, ESCET, Dept Chem & Energy Technol, Mostoles 28933, Spain
关键词
Binary-cycle power plant; Cumulative energy demand; Geothermal energy; Heat pump; Life cycle assessment; ENERGY; DESIGN; FLUIDS;
D O I
10.1016/j.geothermics.2014.03.012
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This article addresses the life cycle assessment of (i) power generation in a binary-cycle power plant using high-enthalpy geothermal resources, and (ii) heat generation in a closed-loop geothermal heat pump system using low-enthalpy resources. For the geothermal power system, production and injection wells show a high contribution to the environmental impacts, mainly due to activities such as drilling and casing. Power plant operation is also identified as an important source of impact because of working fluid losses. A favourable life-cycle energy balance is estimated for this system. Furthermore, when compared to fossil electricity, geothermal electricity is generally found to be a promising alternative. For the geothermal heat system, the electricity demands for heat generation and use are the main sources of impact. An unfavourable life-cycle energy performance is predicted for this system. When compared to fossil heat, the environmental suitability of geothermal heat highly depends on the availability of eco-friendly electrical grids. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:27 / 37
页数:11
相关论文
共 50 条
  • [1] On the environmental suitability of high- and low-enthalpy geothermal systems
    Martín-Gamboa, Mario
    Iribarren, Diego
    Dufour, Javier
    [J]. Geothermics, 2015, 53 : 27 - 37
  • [2] On the environmental suitability of high- and low-enthalpy geothermal systems
    Systems Analysis Unit, Instituto IMDEA Energía, Móstoles
    28935, Spain
    不详
    28933, Spain
    [J]. Geothermics, (27-37):
  • [3] An efficient computational model for deep low-enthalpy geothermal systems
    Saeid, Sanaz
    Al-Khoury, Rafid
    Barends, Frans
    [J]. COMPUTERS & GEOSCIENCES, 2013, 51 : 400 - 409
  • [4] Geothermal application in low-enthalpy regions
    Quick, Hubert
    Michael, Joachim
    Arslan, Ulvi
    Huber, Heiko
    [J]. RENEWABLE ENERGY, 2013, 49 : 133 - 136
  • [5] Characteristics of low-enthalpy geothermal applications in Greece
    Andritsos, N.
    Dalabakis, P.
    Karydakis, G.
    Kolios, N.
    Fytikas, M.
    [J]. RENEWABLE ENERGY, 2011, 36 (04) : 1298 - 1305
  • [6] Doped bentonitic grouts for implementing performances of low-enthalpy geothermal systems
    Marco Viccaro
    [J]. Geothermal Energy, 6
  • [7] Doped bentonitic grouts for implementing performances of low-enthalpy geothermal systems
    Viccaro, Marco
    [J]. GEOTHERMAL ENERGY, 2018, 6 (01):
  • [8] Low-enthalpy geothermal systems for air conditioning: a case study in the Mediterranean climate
    Frau, Caterina
    Maggio, Enrico
    Poggi, Francesca
    Melis, Emanuela
    Floris, Francesco
    Orru, Pier Francesco
    [J]. ATI 2018 - 73RD CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION, 2018, 148 : 527 - 534
  • [9] Power Plant Technologies for Low-Enthalpy Geothermal Energy
    Rohloff, Kathrin
    Kather, Alfons
    [J]. CHEMIE INGENIEUR TECHNIK, 2011, 83 (11) : 1820 - 1833
  • [10] Characterization of low-enthalpy geothermal resources and evaluation of potential contaminants
    Franco Frau
    Rosa Cidu
    Giorgio Ghiglieri
    Guglielmo Angelo Caddeo
    [J]. Rendiconti Lincei. Scienze Fisiche e Naturali, 2020, 31 : 1055 - 1070