Design optimisation for window size, orientation, and wall reflectance with regard to various daylight metrics and lighting energy demand: A case study of buildings in the tropics

被引:158
|
作者
Mangkuto, Rizki A. [1 ]
Rohmah, Mardliyahtur [1 ]
Asri, Anindya Dian [1 ]
机构
[1] Inst Teknol Bandung, Engn Phys Res Grp, Lab Bldg Phys & Acoust, Jl Ganesha 10,Labtek VI, Bandung 40132, Indonesia
关键词
Window-to-wall ratio; Wall reflectance; Facade orientation; Daylight metrics; Lighting energy demand; Optimisation; DOUBLE-PANE WINDOW; OFFICE BUILDINGS; PERFORMANCE; ILLUMINANCE; AREA; AVAILABILITY; SIMULATIONS; ASSESSMENTS; CONSUMPTION; ENVELOPE;
D O I
10.1016/j.apenergy.2015.11.046
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Design optimisation problems of window size and facade orientation in buildings have been investigated many times, with regard to energy and comfort criteria. To indicate daylight availability in indoor spaces, a number of daylight metrics have been proposed, but those metrics are not always fully accounted in the optimisation process. Also, most studies were conducted for locations with high latitude, where the sun is located most of the time either at the south or at the north part of the sky hemisphere, which is not the case in the tropics. Therefore, this article presents a simulation study to investigate the influence of window-to-wall ratio (WWR), wall reflectance, and window orientation on various daylight metrics and lighting energy demand in simple buildings located in the tropical climate. A simple approach for the multi-objective optimisation was proposed by classifying the results in six pairs of two different performance indicators. Solutions in all Pareto frontiers were filtered against the defined target criteria, and were accepted into the optimum solution space if they belong to at least 4 out of 6 Pareto frontiers, and were ranked either in the order of their mean distance to the utopia points, or in the order of number of times they belong to a Pareto frontier. Three optimum solutions are found, all of which belong to four Pareto frontiers. The most optimum solution with the least mean distance to the utopia points is the combination of WWR 30%, wall reflectance of 0.8, and south orientation. The proposed approach enables one to observe the inter-relationship between the involved performance indicators, while providing a possibility to visualise the boundaries of the solution space. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:211 / 219
页数:9
相关论文
共 2 条
  • [1] Theoretical Impact of Building Facade Thickness on Daylight Metrics and Lighting Energy Demand in Buildings: A Case Study of the Tropics
    Mangkuto, Rizki A.
    Atthaillah
    Koerniawan, Mochamad Donny
    Yuliarto, Brian
    [J]. BUILDINGS, 2021, 11 (12)
  • [2] The Effects of Orientation, Window Size, and Lighting Control to Climate-Based Daylight Performance and Lighting Energy Demand on Buildings in Tropical Area
    Fela, Randy Frans
    Utami, Sentagi Sesotya
    Mangkuto, Rizki Armanto
    Suroso, Dwi Joko
    [J]. PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 1075 - 1082