Effective fluoride removal using granular bauxite filter media as an affordable and sustainable alternative to activated alumina

被引:1
|
作者
Cherukumilli, Katya [1 ]
Steiner, Max [2 ]
Ray, Jessica R. [1 ]
机构
[1] Univ Washington, Dept Civil & Environm Engn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Chem Engn, Seattle, WA 98195 USA
关键词
AQUEOUS-SOLUTION; ADSORPTION-KINETICS; DRINKING-WATER; DEFLUORIDATION; PERFORMANCE; CARBON; ADSORBENT; OPTIMIZATION; EQUILIBRIUM; GROUNDWATER;
D O I
10.1039/d1ew00033k
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Despite centuries of advancements in water treatment, hundreds of millions of people worldwide continue to suffer detrimental health impacts from drinking water with unsafe fluoride levels. Our study compares the performance of low-cost mildly heated bauxite ores and commercial activated alumina (AA) in treating a synthetic groundwater matrix representative of global, fluoride-contaminated aquifers. Batch kinetics studies of fluoride adsorption onto global bauxite ores and AA follow a pseudo-second order rate law, with adsorption increasing exponentially in the first few hours. Fluoride removal efficiencies increase from 73.5% to 85.5% as media particle sizes decrease from 0.6-1.2 mm to <0.1 mm. Column studies demonstrate that increasing the ratio of reactive media in filters from 1 to 100 weight percent increases the volume of treated water from 0.2-56.1 L for Guinea bauxite (GB) and from 0.5-58.3 L for AA. We predict the performance of large-scale columns by modifying the bed depth service time (BDST) model to scale breakthrough time with adsorbent mass rather than with column height. Our modified BDST model predicts that large-scale columns using 1039 kg AA and 1436 kg GB can treat 405 444 L and 338 859 L of potable water in 1.4 and 1.1 months. We also demonstrate application of the rapid small scale column test (RSSCT) model to design smaller lab-scale columns with lower resource, cost, and time inputs by scaling down known field systems parameters including column height, pump flow rate, empty bed contact time, and approach velocity.
引用
收藏
页码:1465 / 1479
页数:15
相关论文
共 18 条
  • [1] Fibrous and granular activated carbon mixed media for effective gas removal as a cabin air filter
    Jae-Hyung Wee
    Younghwan Bae
    Hyunchul Ahn
    Yeong Og Choi
    Euigyung Jeong
    Sang Young Yeo
    [J]. Carbon Letters, 2022, 32 : 1111 - 1118
  • [2] Fibrous and granular activated carbon mixed media for effective gas removal as a cabin air filter
    Wee, Jae-Hyung
    Bae, Younghwan
    Ahn, Hyunchul
    Choi, Yeong Og
    Jeong, Euigyung
    Yeo, Sang Young
    [J]. CARBON LETTERS, 2022, 32 (04) : 1111 - 1118
  • [3] Comparison of Activated Alumina and Coal Sand Filter Media for Phosphorus Removal
    Wang, Junling
    Zhang, Yajun
    Li, Junqi
    [J]. WATER INFRASTRUCTURE FOR SUSTAINABLE COMMUNITIES: CHINA AND THE WORLD, 2010, : 355 - 362
  • [4] Comparative Study of Powdered Activated Alumina with Granular Polymer-Agglomerated Alumina in Fluoride Removal from Drinking Water
    Sivasankari, C.
    Mahadevan, M.
    Arulanantham, A.
    [J]. ASIAN JOURNAL OF CHEMISTRY, 2010, 22 (06) : 4663 - 4670
  • [5] Removal of Fluoride from Drinking Water Using Modified Immobilized Activated Alumina
    Rafique, Aneeza
    Awan, M. Ali
    Wasti, Ayesha
    Qazi, Ishtiaq A.
    Arshad, Muhammad
    [J]. JOURNAL OF CHEMISTRY, 2013, 2013
  • [6] Rapid removal of fluoride from aqueous media using activated dolomite
    Chaudhary, Veena
    Prasad, Surendra
    [J]. ANALYTICAL METHODS, 2015, 7 (19) : 8304 - 8314
  • [7] Removal of fluoride from wastewater using HCl-treated activated alumina in a ribbed hydrocyclone separator
    Patra, Gayatree
    Das, Priyam
    Chakraborty, S.
    Meikap, B. C.
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2018, 53 (07): : 601 - 608
  • [8] Removal of oil and grease contamination from stream water using the granular activated carbon block filter
    Mohamad Ali Fulazzaky
    Roslan Omar
    [J]. Clean Technologies and Environmental Policy, 2012, 14 : 965 - 971
  • [9] Removal of oil and grease contamination from stream water using the granular activated carbon block filter
    Fulazzaky, Mohamad Ali
    Omar, Roslan
    [J]. CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2012, 14 (05) : 965 - 971
  • [10] Fluoride Removal from Water using Chitosan Coated Activated Carbon and Cuttle Bone Ash in Combination with Alumina
    Laly, S. J.
    Priya, E. R.
    Zynudheen, A. A.
    [J]. FISHERY TECHNOLOGY, 2020, 57 (03): : 184 - 189