Practical application of HDRI for discomfort glare assessment at indoor workplaces

被引:12
|
作者
Wolska, Agnieszka [1 ]
Sawicki, Dariusz [2 ]
机构
[1] Natl Res Inst, Cent Inst Labour Protect, Warsaw, Poland
[2] Warsaw Univ Technol, Inst Theory Elect Engn Measurements & Informat Sy, Warsaw, Poland
关键词
Luminance measurement; Discomfort glare assessment; UGR; HDRI; ILMD; Array photometer; QUALITY;
D O I
10.1016/j.measurement.2019.107179
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Unified Glare Rating (UGR) is a measure of discomfort glare at indoor workplaces. Image luminance measuring device (ILMD), as an array photometer, makes it possible to measure the luminance distribution in the form of luminance map. It is the base for UGR calculation by an appropriate computer program. The range of measured luminance depends mainly on a glare source luminance, which often significantly exceeds the abilities of an array photometer sensor. High dynamic range (HDR) method, which is used in photography, can solve this problem partially. A practical approach to this problem was presented in the paper. A new procedure for preparing the set of photos for building HDR images was introduced. This effective method was developed to be used in UGR calculations. The use of the proposed procedure makes it possible to perform UGR measurements reliably, quickly, and efficiently, even by nonexperts in the field of lighting engineering. (C) 2019 The Author(s). Published by Elsevier Ltd.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Objective assessment of glare at outdoor workplaces
    Sawicki, Dariusz
    Wolska, Agnieszka
    [J]. BUILDING AND ENVIRONMENT, 2019, 149 : 537 - 545
  • [2] OBJECTIVE AND SUBJECTIVE ASSESSMENT OF DISCOMFORT GLARE
    BAILEY, IL
    BERMAN, SM
    JACOBS, RJ
    BULLIMORE, MA
    GANDHI, N
    GREENHOUSE, DS
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 966 - 966
  • [3] A PSYCHOPHYSICAL MODEL OF DISCOMFORT GLARE IN BOTH OUTDOOR AND INDOOR APPLICATIONS
    Donners, M. A. H.
    Vissenberg, M. C. J. M.
    Geerdinck, L. M.
    van den Broek-Cools, J. H. F.
    Buddemeijer-Lock, A.
    [J]. PROCEEDINGS OF CIE 2016 LIGHTING QUALITY AND ENERGY EFFICIENCY, 2016, : 142 - 151
  • [4] Assessment of pedestrian discomfort glare from urban LED lighting
    Villa, C.
    Bremond, R.
    Saint-Jacques, E.
    [J]. LIGHTING RESEARCH & TECHNOLOGY, 2017, 49 (02) : 147 - 172
  • [5] Methodology for the assessment of glare in indoor work environments
    Long, Jennifer
    [J]. CONTEMPORARY ERGONOMICS 2007, 2007, : 421 - 426
  • [6] Discomfort glare assessment and prevention for daylight applications in office environments
    Osterhaus, WKE
    [J]. SOLAR ENERGY, 2005, 79 (02) : 140 - 158
  • [7] Design of Lighting Control System Considering Lighting Uniformity and Discomfort Glare for Indoor Space
    Byun, Woon-Jo
    Jin, Ye-Seul
    Kim, Young-Won
    Lim, Jae-Hyun
    [J]. 2018 INTERNATIONAL CONFERENCE ON PLATFORM TECHNOLOGY AND SERVICE (PLATCON18), 2018, : 38 - 41
  • [8] A practical approach to glare assessment for train cabs
    Jenkins, Daniel P.
    Baker, Lisa M.
    Harvey, Carl
    [J]. APPLIED ERGONOMICS, 2015, 47 : 170 - 180
  • [9] View types and luminance effects on discomfort glare assessment from windows
    Shin, Ju Young
    Yun, Geun Young
    Kim, Jeong Tai
    [J]. ENERGY AND BUILDINGS, 2012, 46 : 139 - 145
  • [10] The Usefulness of Near-Field Goniophotometry Data to Assess Illuminances and Discomfort Glare in Indoor Lighting
    Simonot, L.
    Reux, F.
    Carre, S.
    Martinsons, C.
    [J]. LEUKOS, 2022, 18 (02) : 246 - 257