Development of a fluorescence immunoassay for measurement of paclitaxel in human plasma

被引:23
|
作者
Sheikh, SH [1 ]
Abela, BA [1 ]
Mulchandani, A [1 ]
机构
[1] Univ Calif Riverside, Dept Chem & Environm Engn, Riverside, CA 92521 USA
基金
美国国家科学基金会;
关键词
D O I
10.1006/abio.2000.4630
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new fluorescence immunoassay for the quantitative determination of paclitaxel (Pac) under equilibrium conditions was developed. Anti-Pac IgG2a antibody was immobilized through its Pc region to protein A covalently bound to the inside surface of a silanized glass capillary column and the antigen-binding sites of anti-Pac saturated with rhodamine-labeled Pac (Rh-Pac). Analyte Pac was circulated through the column in a closed loop and the steady-state fluorescence of the Rh-Pac displaced from the immobilized antibody was recorded after 6 min. The Ph-Pac fluorescence emission intensity was directly related to the concentration of the Pac analyte over a broad dynamic range of up to 400 ng/ml with a linear range up to 200 ng/ml and lower detection limit of 5.85 ng/ml. While there was no interference from the baccatin III and 10-deacetylbaccatin III, cephalomannine was found to interfere in Pac determination. When applied for measurement of Pac in human plasma, the concentration of Pac determined by the fluorescence assay was found to be in excellent agreement with the Pac added, confirming the potential of the fluorescence immunoassay for clinical application. (C) 2000 Academic Press.
引用
收藏
页码:33 / 38
页数:6
相关论文
共 50 条
  • [1] Development of a fluorescence polarization immunoassay (FPIA) for the quantitative determination of paclitaxel
    Bicamumpaka, C
    Pagé, M
    JOURNAL OF IMMUNOLOGICAL METHODS, 1998, 212 (01) : 1 - 7
  • [2] Measurement of fraction unbound paclitaxel in human plasma
    Brouwer, E
    Verweij, J
    De Bruijn, P
    Loos, WJ
    Pillay, M
    Buijs, D
    Sparreboom, A
    DRUG METABOLISM AND DISPOSITION, 2000, 28 (10) : 1141 - 1145
  • [4] EVALUATION OF FLUORESCENCE EXCITATION TRANSFER IMMUNOASSAY FOR THE MEASUREMENT OF PLASMA-CORTISOL
    CALVIN, J
    BURLING, K
    CAMPBELL, RS
    CHUBB, SAP
    PRICE, CP
    JOURNAL OF AUTOMATIC CHEMISTRY, 1986, 8 (02): : 80 - 84
  • [5] MEASUREMENT OF CYCLOSPORINE IN PLASMA OF CARDIAC ALLOGRAFT RECIPIENTS BY FLUORESCENCE POLARIZATION IMMUNOASSAY
    RONDANELLI, R
    REGAZZI, MB
    GASTALDI, L
    LEGNAZZI, P
    ABELLI, P
    THERAPEUTIC DRUG MONITORING, 1990, 12 (02) : 182 - 186
  • [6] A comparison of radioimmunoassay and dissociation enhanced lanthanide fluorescence immunoassay for the analysis of a novel development candidate in human plasma
    Singh, J
    Lockley, WJS
    Preston, JR
    Mather, AN
    Willson, VJC
    Gilbert, CM
    Bayliss, MAJ
    SYNTHESIS AND APPLICATIONS OF ISOTOPICALLY LABELLED COMPOUNDS 1997, 1998, : 563 - 566
  • [7] EXPERIENCE WITH FLUORESCENCE ENERGY-TRANSFER IMMUNOASSAY FOR THE MEASUREMENT OF PLASMA-CORTISOL
    CALVIN, J
    BURLING, K
    CAMPBELL, RS
    PRICE, CP
    CLINICAL CHEMISTRY, 1984, 30 (06) : 1042 - 1042
  • [8] Rapid measurement of plasma methadone in a clinical setting using fluorescence polarization immunoassay
    Kell, MJ
    Techman, T
    JOURNAL OF ADDICTIVE DISEASES, 1996, 15 (02) : 69 - 83
  • [9] DEVELOPMENT OF A MONOCLONAL IMMUNOASSAY FOR THE DIRECT MEASUREMENT OF DECARBOXY PROTHROMBIN ON PLASMA
    AMIRAL, J
    GROSLEY, M
    PLASSART, V
    MIMILLA, F
    CHAMBRETTE, B
    THROMBOSIS AND HAEMOSTASIS, 1991, 65 (06) : 648 - 648
  • [10] MEASUREMENT OF GLUCAGON IN HUMAN-PLASMA BY ENZYME-IMMUNOASSAY
    OHNEDA, A
    KOBAYASHI, T
    NIHEI, J
    IWASA, S
    KONDO, K
    JOURNAL OF IMMUNOASSAY, 1983, 4 (04): : 339 - 349