Comparison of Bone Marrow Biopsy Specimens Obtained Using a Motorized Device and Manual Biopsy Systems

被引:4
|
作者
Glennon, Catherine A. [1 ]
Woodroof, Janet M. [2 ]
Kambhampati, Suman [3 ]
Battershell, Alexis C. [4 ]
O'Connor, Serena R. [4 ]
Roberts, Kiley B. [4 ]
机构
[1] Univ Kansas, Canc Ctr, Westwood, KS USA
[2] Univ Kansas Hosp, Dept Pathol, Kansas City, KS USA
[3] Sarah Cannon Canc Inst, Res Med Ctr, Kansas City, MO USA
[4] Univ Kansas, Med Ctr, Kansas City, KS 66103 USA
关键词
Bone marrow aspiration and biopsy; crush artifact; manual approach; motorized device; pathology; quality; ASPIRATION;
D O I
10.4103/apjon.apjon_26_18
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objective: Bone marrow biopsy is an essential component in the diagnosis of hematopoietic disorders. Researchers evaluated the quality of bone marrow biopsy tissue acquired with a motorized bone marrow biopsy device versus a standard manual device based on the following criteria: biopsy length, percentage of aspiration artifact/intrastromal hemorrhage, length of nonhematopoietic bone, and overall quality of the sample. Methods: Bone marrow biopsies (motorized, n = 30; manual, n = 120) from two academic medical centers were evaluated by two board-certified hematopathologists. For each specimen, the following parameters were recorded: biopsy length (cm), aspiration artifact (assessed in intervals of <= 10%, 11%-25%, 26%-50%, 51%-75%, and >75%), length (cm) of nonhematopoietic biopsy (e.g., cortical bone and skin), and overall quality of sample (inadequate, suboptimal, adequate, and excellent). Results: Operators from two centers included physicians and nurse practitioners. The manual system was superior to the powered drill with respect to the amount of crush artifact (0.15 cm +/- 0.01 vs. 0.24 cm +/- 0.04, P = 0.01 [t-test]). There was a trend toward less aspiration artifact/intrastromal hemorrhage with the use of the manual biopsy; however, the difference was not statistically significant (P = 0.06). There was no statistically significant difference in the overall biopsy size, biopsy length, amount of nonhematopoietic elements, and overall adequacy of the sample. Conclusions: There was no significant difference in the biopsy length, amount of nonhematopoietic elements, and overall adequacy of the sample. Results suggest that the manual bone marrow biopsy device has significantly less crush artifact of the specimen and has a trend toward less aspiration artifact/intrastromal hemorrhage as well.
引用
收藏
页码:394 / 398
页数:5
相关论文
共 50 条
  • [1] Comparison Of a Powered Bone Marrow Aspiration and Biopsy Device To The Traditional Manual Device In Children
    Falcon-Cantrill, Maria G.
    Thomas, Paul
    Saldivar, Victor
    Philbeck, Thomas E.
    Assanasen, Chatchawin
    BLOOD, 2013, 122 (21)
  • [2] Comparison of a Rotary Powered Bone Marrow Aspiration and Biopsy Device to the Traditional Manual Device in an Adolescent
    Falcon, Maria G.
    Assanasen, Chatchawin
    Thomas, Paul
    Saldivar, Victor
    BLOOD, 2012, 120 (21)
  • [3] COMPARISON OF A ROTARY POWERED BONE MARROW ASPIRATION AND BIOPSY DEVICE TO THE TRADITIONAL MANUAL DEVICE IN CHILDREN
    Falcon-Cantrill, Maria
    Thomas, Paul
    Saldivar, Victor
    Assanasen, Chatchawin
    PEDIATRIC BLOOD & CANCER, 2013, 60 : S8 - S8
  • [4] COMPARISON OF A ROTARY POWERED BONE MARROW ASPIRATION AND BIOPSY DEVICE TO THE TRADITIONAL MANUAL DEVICE IN CHILDREN
    Falcon-Cantrill, Maria
    Thomas, Paul
    Saldivar, Victor
    Assanasen, Chatchawin
    PEDIATRIC BLOOD & CANCER, 2014, 61 : S28 - S28
  • [5] Comparing Powered Bone Marrow Biopsy Procedures to Manual Bone Marrow Biopsy Procedures Using Healthy Volunteers.
    Miller, Larry
    Philbeck, Thomas
    Montez, Diana
    Puga, Tatiana
    Brenner, Andrew
    Cohen, Stephen C.
    Spadaccini, Cathy
    BLOOD, 2010, 116 (21) : 648 - 648
  • [6] Comparison of a powered bone marrow biopsy device with a manual system: results of a prospective randomised controlled trial
    Bucher, Christoph Marcus
    Lehmann, Thomas
    Tichelli, Andre
    Tzankov, Alexander
    Dirnhofer, Stephan
    Passweg, Jakob
    Rovo, Alicia
    JOURNAL OF CLINICAL PATHOLOGY, 2013, 66 (01) : 24 - 28
  • [7] BONE MARROW BIOPSY WITH UNALTERED ARCHITECTURE - NEW BIOPSY DEVICE
    JAMSHIDI, K
    SWAIM, WR
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1971, 77 (02): : 335 - &
  • [8] STREAMLINING THE PROCESSING OF BONE MARROW BIOPSY SPECIMENS
    Wolfe, Jennifer
    Berizzi, Donna
    ONCOLOGY NURSING FORUM, 2018, 45 (02)
  • [9] BONE MARROW SAMPLING USING A ROTARY POWERED DEVICE YIELDS EXCELLENT BIOPSY SPECIMENS IN AN ANIMAL MODEL
    Brenner, A.
    Miller, L.
    Philbeck, T.
    Hacker, S.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2009, 94 : 620 - 620
  • [10] Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions
    Cohen, Micah G.
    McMahon, Colm J.
    Kung, Justin W.
    Wu, Jim S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (05) : W83 - W86