A fluorescence resonance energy transfer sensor for the β-domain of metallothionein

被引:52
|
作者
Hong, SH [1 ]
Maret, W [1 ]
机构
[1] Harvard Univ, Sch Med, Ctr Biochem & Biophys Sci & Med, Cambridge, MA 02139 USA
关键词
D O I
10.1073/pnas.0438005100
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We have designed a nanosensor to study the potential function of metallothionein (MT) in metal transfer and its interactions with redox partners and ligands by attaching two fluorescent probes to recombinant human MT. The specific labeling takes advantage of two different modification reactions. One is based on the fact that recombinant MT has a free N-terminal amino group when produced by the IMPACT T7 expression and purification system, the other on the observation that one human MT isoform (1 b) contains an additional cysteine at position 32. It is located in the linker region of the molecule, allowing the introduction of a probe between the two domains. An S32C mutation was introduced into hMT-2. Its thiol reactivity, metal binding capacity, and CD and UV spectra all demonstrate that the additional cysteine contains a free thiol(ate); it perturbs neither the overall structure of the protein nor the formation of the metal/thiolate clusters. MT containing only cadmium was labeled stoichiometrically with Alexa 488 succinimidyl ester at the N terminus and with Alexa 546 maleimide at the free thiol group, followed by conversion to MT containing only zinc. Energy transfer between Alexa 488 (donor) and Alexa 546 (acceptor) in double-labeled MT allows the monitoring of metal binding and conformational changes in the IN-terminal beta-domain of the protein.
引用
下载
收藏
页码:2255 / 2260
页数:6
相关论文
共 50 条
  • [1] Domain-specific fluorescence resonance energy transfer (FRET) sensors of metallothionein/thionein
    Hong, SH
    Hao, Q
    Maret, W
    PROTEIN ENGINEERING DESIGN & SELECTION, 2005, 18 (06): : 255 - 263
  • [2] Sensor peptides based on fluorescence resonance energy transfer
    Yokoyama, K
    Matsumoto, M
    Ishikawa, H
    Morita, Y
    Tamiya, E
    BIOLOGICAL SYSTEMS ENGINEERING, 2002, 830 : 248 - 258
  • [3] Fluorescence resonance energy transfer disposable sensor for copper(II)
    Cano-Raya, C
    Fernández-Ramos, MD
    Capitán-Vallvey, LF
    ANALYTICA CHIMICA ACTA, 2006, 555 (02) : 299 - 307
  • [4] Correlation between Activity and Domain Complementation in Adenylyl Cyclase Demonstrated with a Novel Fluorescence Resonance Energy Transfer Sensor
    Ritt, Michael
    Sivaramakrishnan, Sivaraj
    MOLECULAR PHARMACOLOGY, 2016, 89 (04) : 407 - 412
  • [5] Effect of membrane microheterogeneity and domain size on fluorescence resonance energy transfer
    Towles, Kevin B.
    Brown, Angela C.
    Wrenn, Steven P.
    Dan, Nily
    BIOPHYSICAL JOURNAL, 2007, 93 (02) : 655 - 667
  • [6] DOMAIN MOTION IN ACTIN OBSERVED BY FLUORESCENCE RESONANCE ENERGY-TRANSFER
    MIKI, M
    KOUYAMA, T
    BIOCHEMISTRY, 1994, 33 (33) : 10171 - 10177
  • [7] Domain Size Dependent Fluorescence Resonance Energy Transfer in Lipid Domain Incorporated Fluorophores
    Hatae, Tatsuru
    Koshiyama, Tomomi
    Ohba, Masaaki
    CHEMISTRY LETTERS, 2017, 46 (05) : 756 - 759
  • [8] Development of hard water sensor using fluorescence resonance energy transfer
    Dey, Dibyendu
    Bhattacharjee, D.
    Chakraborty, S.
    Hussain, Syed Arshad
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 184 : 268 - 273
  • [9] Development of arsenic(v) sensor based on Fluorescence Resonance Energy Transfer
    Saha, Jaba
    Roya, Arpan Datta
    Dey, Dibyendu
    Nath, Jayasree
    Bhattacharjee, D.
    Hussain, Syed Arshad
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 241 : 1014 - 1023
  • [10] A fluorescence resonance energy transfer sensor based on maltose binding protein
    Medintz, IL
    Goldman, ER
    Lassman, ME
    Mauro, JM
    BIOCONJUGATE CHEMISTRY, 2003, 14 (05) : 909 - 918