Thermo and flex multi-functional array ionic sensor for a human adaptive device

被引:3
|
作者
Jang, Sukjin [1 ,2 ]
Choi, Daehwan [1 ,2 ]
Yang, Suk [1 ,2 ]
Kwon, Jang-Yeon [1 ,2 ]
机构
[1] Yonsei Univ, Sch Integrated Technol, Incheon 21983, South Korea
[2] Yonsei Univ, Yonsei Inst Convergence Technol, Incheon 21983, South Korea
基金
新加坡国家研究基金会;
关键词
TEMPERATURE SENSOR; DOUBLE-LAYER; CAPACITANCE; TRANSPARENT; SKIN;
D O I
10.1039/c9ra08188g
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Recently, electronic skin that mimics human skin in measuring tactile stimuli, temperature, and humidity and having a self-healing function was developed. Furthermore, with the advances in the field of artificial intelligence and health monitoring, various materials and methods have been studied for e-skin. The limitations to work on actual human skin include device flexibility and large-area applications through array structures, and many studies are underway to overcome these problems. Polymeric materials containing ionic liquids can be used to easily fabricate devices in the solid state. They are highly sensitive to both pressure and temperature, making them suitable for multi-sensing devices. Resistive and capacitive sensors have the advantage of having a simple structure, which makes them easy to fabricate. In a single device, both types work well. For resistive sensors, the temperature sensitivity (1.1/degrees C) is relatively high. Conversely, capacitive sensors have a low temperature sensitivity (0.3/degrees C). However, they have the advantage of being uniformly variable under each condition and having a smaller error range. In the array structure, independent flex and thermo sensors are arranged repeatedly. The resistive type shows changes in temperature and bending, but in the capacitive type, it is difficult to obtain results from the pixels due to parasitic capacitance.
引用
收藏
页码:36960 / 36966
页数:7
相关论文
共 50 条
  • [1] An adaptive multi-functional array for wireless sensor systems
    Miyamoto, RY
    Leong, KMKH
    Jeon, SS
    Wang, YX
    Itoh, T
    [J]. 2002 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 2002, : 1369 - 1372
  • [2] Multi-functional sensor array on the cryoablation balloon for atrial fibrillation
    Hong, Wen
    Xu, Mengfei
    Guo, Zhejun
    Wang, Longchun
    Qin, Mu
    Liu, Jingquan
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2022, 341
  • [3] The multi-functional surgical device
    Ragoowansi, R
    Manushakian, J
    [J]. ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2005, 87 (04) : 289 - 290
  • [4] MULTI-FUNCTIONAL ELECTROOPTIC DEVICE WITH FEEDBACK
    OKADA, M
    TAKIZAWA, K
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 1979, 18 (01) : 133 - 137
  • [5] ADAPTIVE MULTI-FUNCTIONAL HAND PROSTHESIS
    CODD, RD
    NIGHTINGALE, JM
    TODD, RW
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1973, 232 (02): : P55 - P56
  • [6] A Multi-Functional Penta-Needle Thermo-Dielectric Sensor for Porous Media Sensing
    Sheng, Wenyi
    Rumana, Kashifa
    Sakai, Masaru
    Silfa, Franyell
    Jones, Scott B.
    [J]. IEEE SENSORS JOURNAL, 2016, 16 (10) : 3670 - 3678
  • [7] Flexible and Multi-Functional Graphene Sensor Platform
    Kaidarova, Altynay
    Almoudi, Abeer
    Allagani, Renad M.
    Marengo, Marco
    Khan, Mohammed A.
    Buttner, U.
    Duarte, Carlos M.
    Kosel, Jurgen
    [J]. PROCEEDINGS OF THE 2019 IEEE INTERNATIONAL CONFERENCE ON FLEXIBLE AND PRINTABLE SENSORS AND SYSTEMS (IEEE FLEPS 2019), 2019,
  • [8] A multi-functional sensor for oil condition evaluation
    Jakoby, B
    Eisenschmid, H
    Schatz, O
    Bosch, R
    [J]. TECHNISCHES MESSEN, 2001, 68 (05): : 204 - 207
  • [9] An oil condition monitoring multi-functional sensor
    Shida, K
    Preethichandra, DMG
    [J]. ICEMI'99: FOURTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 1999, : 496 - 501
  • [10] A multi-functional sensor for liquid characterization and identification
    Preethichandra, DMG
    Shida, K
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (3A): : 1482 - 1486