Quantification of volumetric blood flow in coronary arteries using Doppler flow wire: An in vivo validation

被引:0
|
作者
Mandinov, L [1 ]
Lachat, M [1 ]
Leskosek, B [1 ]
Linka, AZ [1 ]
Bettex, D [1 ]
Jenni, R [1 ]
机构
[1] Univ Zurich Hosp, CH-8091 Zurich, Switzerland
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
3102
引用
收藏
页码:639 / 640
页数:2
相关论文
共 50 条
  • [1] In vitro validation of volumetric blood flow measurement using Doppler flow wire
    Jenni, R
    Kaufmann, PA
    Jiang, ZH
    Attenhofer, C
    Linka, A
    Mandinov, L
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (08): : 1301 - 1310
  • [2] A new Doppler method for quantification of volumetric flow: In vivo validation using color Doppler
    Kim, WY
    Poulsen, JK
    Terp, K
    Staalsen, NH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (01) : 182 - 192
  • [3] Quantification of coronary microvascular resistance using angiographic images for volumetric blood flow measurement: in vivo validation
    Zhang, Zhang
    Takarada, Shigeho
    Molloi, Sabee
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2011, 300 (06): : H2096 - H2104
  • [4] Volumetric evaluation of blood flow in normal renal arteries with a Doppler flow wire: A feasibility study
    Savader, SJ
    Lund, GB
    Osterman, FA
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (02) : 209 - 214
  • [5] A NEW DOPPLER METHOD FOR QUANTIFICATION OF VOLUMETRIC FLOW - IN-VITRO AND IN-VIVO VALIDATION USING COLOR DOPPLER
    KIM, WY
    POULSEN, JK
    TERP, K
    STAALSEN, NH
    CIRCULATION, 1995, 92 (08) : 70 - 70
  • [6] Quantification of myocardial blood flow reserve in humans using myocardial contrast echocardiography: Validation with Doppler flow wire measurements
    Wei, K
    Ragosta, M
    Thorpe, J
    Doss, A
    Coggins, MP
    Kaul, S
    CIRCULATION, 1999, 100 (18) : 368 - 368
  • [7] Direct assessment of volumetric blood flow from Doppler signal power using a Doppler flow wire system
    Mandinov, L
    Linka, A
    Lazar, L
    Jenni, R
    EUROPEAN HEART JOURNAL, 2000, 21 : 687 - 687
  • [8] Regional volumetric coronary blood flow measurement by digital angiography: In vivo validation
    Molloi, S
    Zhou, YF
    Kassab, GS
    ACADEMIC RADIOLOGY, 2004, 11 (07) : 757 - 766
  • [9] Intravascular estimation of volumetric blood flow from Doppler powers using a Doppler guide wire
    Mandinov, L
    Linka, A
    Jenni, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 93A - 93A
  • [10] VALIDATION OF VOLUMETRIC FLOW MEASUREMENTS BY MEANS OF A DOPPLER-TIPPED CORONARY ANGIOPLASTY GUIDE-WIRE
    LABOVITZ, AJ
    ANTHONIS, DM
    CRAVENS, TL
    KERN, MJ
    AMERICAN HEART JOURNAL, 1993, 126 (06) : 1456 - 1461