Ultrafiltration as tertiary treatment for municipal wastewater reuse

被引:0
|
作者
Yang, J. [1 ]
Monnot, M. [1 ]
Eljaddi, T. [1 ]
Ercolei, L. [2 ]
Simonian, L. [1 ]
Moulin, P. [1 ]
机构
[1] Aix Marseille Univ, Lab Mecan Modelisat & Proc Propres, Equipe Procedes Membranaire EPMM M2P2, CNRS,UMR 7340, BP 80,Bat Laennec, F-13545 Aix En Provence 04, France
[2] Soc Eaux Marseille Metropole, 25 Rue Edouard Delanglade,BP 29, F-13006 Marseille 06, France
关键词
Ultrafiltration; Tertiary treatment; Wastewater treatment; Water reuse; Fouling management; EFFLUENT ORGANIC-MATTER; HOLLOW-FIBER MEMBRANE; FOULING DEPOSITION; SODIUM ALGINATE; UF; REMOVAL; TEMPERATURE; PERFORMANCE; FLUX; AGRICULTURE;
D O I
10.1016/j.seppur.2021.118921
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Water reuse is an enduring topic that benefits the society and future generations of mankind. Ultrafiltration (UF) is one of the most cost-effective treatment technologies for improving water quality. In this study, a semiindustrial UF pilot plant with periodical classic backwash (CB) and air backwash (AB) was operated automatically to evaluate its feasibility and sustainability for municipal wastewater reuse and find out the optimized filtration condition. This study carried out 15 filtration conditions to investigate the impacts of flux (J in L center dot h-1 center dot m- 2), filtration cycle time (t in min), and air backwash frequency (BW) on membrane hydraulic filtration performance and membrane fouling management. Through comparative analysis of all conditions in water quality, permeability variation, irreversible fouling management, and water recovery rates, the sustainable conditions J80t40BW1/3 (flux of 80 L center dot h- 1 center dot m- 2, filtration cycle time of 40 min, 1 AB followed with 3 CBs), J60t60BW1/4 (flux of 60 L center dot h- 1 center dot m- 2, filtration cycle time of 60 min, 1 AB followed with 4 CBs), and J60t60BW1/ 3 (flux of 60 L center dot h- 1 center dot m- 2, filtration cycle time of 60 min, 1 AB followed with 3 CBs), stood out from the others with higher overall performances. Additionally, air backwash showed excellent reversibility on membrane fouling control, which was around 1.25-2 times that of CB in average. After all, long term operation on condition J60t60BW1/3 in winter and in summer confirmed that the UF system could provide sustainable and adaptable filtration performance regardless of the temperature and feed water quality. The UF permeate quality is good enough to be reused in non-potable applications as it met reuse guidelines of the World Health Organization, reuse standards of France and the most recent EU regulation for agricultural irrigation. This work confirms the great interest of UF as tertiary treatment for water reuse and gives operational indications for future industrialscale production of reclaimed water.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Ultrafiltration as tertiary treatment for municipal wastewater reuse
    Yang, J.
    Monnot, M.
    Eljaddi, T.
    Ercolei, L.
    Simonian, L.
    Moulin, P.
    [J]. Separation and Purification Technology, 2021, 272
  • [2] Ultrafiltration as an advanced tertiary treatment process for municipal wastewater
    Tchobanoglous, G
    Darby, J
    Bourgeous, K
    McArdle, J
    Genest, P
    Tylla, M
    [J]. DESALINATION, 1998, 119 (1-3) : 315 - 321
  • [3] Ultrafiltration as tertiary treatment for industrial reuse
    Lubello, C
    Gori, R
    de Bernardinis, AM
    Simonelli, G
    [J]. WATER RECYCLING IN THE MEDITERRANEAN REGION, 2003, 3 (04): : 161 - 168
  • [4] Wastewater reuse after treatment by tertiary ultrafiltration and a membrane bioreactor (MBR): a comparative study
    Arevalo, Juan
    Garralon, Gloria
    Plaza, Fidel
    Moreno, Begona
    Perez, Jorge
    Angel Gomez, Miguel
    [J]. DESALINATION, 2009, 243 (1-3) : 32 - 41
  • [5] Combination of ultrafiltration, activated carbon and disinfection as tertiary treatment of urban wastewater for reuse in agriculture
    Diallo, Haby Mamadou
    Elazhar, Fatima
    Elmidaoui, Azzedine
    Taky, Mohamed
    [J]. DESALINATION AND WATER TREATMENT, 2024, 320
  • [6] Role of membrane pore size in tertiary flocculation/adsorption/ultrafiltration treatment of municipal wastewater
    Goren, Uri
    Aharoni, Avi
    Kummel, Mario
    Messalem, Rami
    Mukmenev, Igor
    Brenner, Asher
    Gitis, Vitaly
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2008, 61 (02) : 193 - 203
  • [7] Ozone reactor combined with ultrafiltration membrane: A new tertiary wastewater treatment system for reuse purpose
    Clem, Vitoria
    de Mendonca, Henrique Vieira
    [J]. JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2022, 315
  • [8] The applications of MBR in municipal wastewater treatment and reuse
    Li, Jian
    Yang, Yun Long
    Xue, Kai
    [J]. PROGRESS IN ENVIRONMENTAL PROTECTION AND PROCESSING OF RESOURCE, PTS 1-4, 2013, 295-298 : 1045 - 1048
  • [9] Municipal wastewater treatment and reuse in Saudi Arabia
    AlRehaili, AM
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 1997, 22 (1C): : 143 - 152
  • [10] Coagulation-adsorption-ultrafiltration for wastewater treatment and reuse
    Abdessemed, D
    Nezzal, G
    Ben Aim, R
    [J]. MEMBRANES IN DRINKING AND INDUSTRIAL WATER PRODUCTION III, 2003, : 361 - 365