High-performance liquid chromatography with peroxyoxalate chemiluminescence detection of bisphenol A migrated from polycarbonate baby bottles using 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride as a label

被引:56
|
作者
Sun, Y
Wada, M
Al-Dirbashi, O
Kuroda, N
Nakazawa, H
Nakashima, K
机构
[1] Nagasaki Univ, Grad Sch Pharmaceut Sci, Nagasaki 8528521, Japan
[2] Nagasaki Univ, Sch Pharmaceut Sci, Nagasaki 8528521, Japan
[3] Hoshi Univ, Fac Pharmaceut Sci, Shinagawa Ku, Tokyo 142, Japan
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 749卷 / 01期
关键词
polycarbonate bottle; peroxyoxalate chemiluminescence detection; bisphenol A; 4-(4,5-diphenyl-1H-imidazol-2-yl); benzoyl chloride;
D O I
10.1016/S0378-4347(00)00387-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive and selective high-performance liquid chromatographic method with peroxyoxalate chemiluminescence detection for the determination of bisphenol A at sub-ppb levels is described. Bisphenol A was derivatized with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride and the excess unreacted reagent was removed by a simple solid-phase extraction procedure with recoveries of approximately 60%. The separation was carried out isocratically on an ODS column and the derivatized bisphenol A was detected by peroxyoxalate chemiluminescence. A mixture of bis[2-(3,6,9-trioxadecanyloxycarbonyl)-4-nitrophenyl]oxalate (0.6 mM) and hydrogen peroxide (25.0 mM) dissolved in acetonitrile was used as a chemiluminescence reagent solution with a mixture of imidazole-HNO3 buffer (40.0 mM, pH 7.0): acetonitrile (17:83, v/v) as a mobile phase. The linear standard curve was obtained over the range from 0.57 (2.5) to 22.8 (100) ppb (nM) (r=0.996) with a detection limit of 0.38 ppb (2.8 fmol on column) at a signal-to-noise ratio of 3. The method was successfully applied to the determination of bisphenol A in hot water in contact with commercially available baby bottle samples. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 50 条
  • [1] Development of sensitive high-performance liquid chromatography with fluorescence detection using 4-(4,5-diphenyl-1H-imidazol-2-yl)-benzoyl chloride as a labeling reagent for determination of bisphenol A in plasma samples
    Watanabe, T
    Yamamoto, H
    Inoue, K
    Yamaguchi, A
    Yoshimura, Y
    Kato, K
    Nakazawa, H
    Kuroda, N
    Nakashima, K
    JOURNAL OF CHROMATOGRAPHY B, 2001, 762 (01): : 1 - 7
  • [2] Sensitive determination of diethylstilbestrol by high performance liquid chromatography with fluorescence detection with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride as a labeling reagent
    Chen, Peiyun
    Sun, Hanwen
    Wang, Xianyou
    Zhao, Zhilei
    Pang, Yanping
    ANALYTICAL METHODS, 2012, 4 (12) : 4049 - 4052
  • [3] HPLC with fluorescence detection of morphine in rat plasma using 4-(4,5-diphenyl-1H-imidazol-2-YL)benzoyl chloride as a label
    Nakashima, K
    Ogata, Y
    Nakashima, MN
    Wada, M
    Bioluminescence & Chemiluminescence: Progress and Perspectives, 2005, : 257 - 260
  • [4] Sensitive high-performance liquid chromatographic determination with fluorescence detection of phenol and chlorophenols with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride as a labeling reagent
    Wada, M
    Kinoshita, S
    Itayama, Y
    Kuroda, N
    Nakashima, K
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 721 (02): : 179 - 186
  • [5] High performance liquid chromatography with UV detection for the simultaneous determination of sympathomimetic amines using 4-(4,5-diphenyl-1H-imidazole-2-yl)benzoyl chloride as a label
    Kaddoumi, A
    Kubota, A
    Nakashima, MN
    Takahashi, M
    Nakashima, K
    BIOMEDICAL CHROMATOGRAPHY, 2001, 15 (06) : 379 - 388
  • [6] HPLC with fluorescence detection of urinary phenol, cresols and xylenols using 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride as a fluorescence labeling reagent
    Nakashima, K
    Kinoshita, S
    Wada, M
    Kuroda, N
    Baeyens, WRG
    ANALYST, 1998, 123 (11) : 2281 - 2284
  • [7] Simple and sensitive high-performance liquid chromatographic determination of methamphetamines in human urine as derivatives of 4-(4,5-diphenyl-1H-imidazol-2-yl) benzoyl chloride, a new fluorescence derivatization reagent
    Al-Dirbashi, O
    Qvarnstrom, J
    Irgum, K
    Nakashima, K
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1998, 712 (1-2): : 105 - 112
  • [8] Prop-2-en-1-yl 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoate
    Mohamed, Shaaban K.
    Akkurt, Mehmet
    Marzouk, Adel A.
    Abdelhamid, Antar A.
    Santoyo-Gonzalez, Francisco
    ACTA CRYSTALLOGRAPHICA SECTION E-CRYSTALLOGRAPHIC COMMUNICATIONS, 2013, 69 : O1105 - +
  • [9] 4-(4,5-Diphenyl-1H-imidazol-2-yl)-N, N-dimethylaniline
    Prabhuswamy, M.
    Viveka, S.
    Kumar, S. Madan
    Nagaraja, G. K.
    Lokanath, N. K.
    ACTA CRYSTALLOGRAPHICA SECTION E-CRYSTALLOGRAPHIC COMMUNICATIONS, 2013, 69 : O1006 - +
  • [10] A simple and sensitive HPLC-fluorescence method for quantification of MDMA and MDA in blood with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) as a label
    Tomita, Mamoru
    Nakashima, Mihoko N.
    Wada, Mitsuhiro
    Nakashima, Kenichiro
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (12) : 1380 - 1385