ICD Lead Failure Detection in Chronic Soaked Leads

被引:0
|
作者
Kollmann, Daniel T. [1 ]
Swerdlow, Charles D. [2 ]
Kroll, Mark W. [3 ,4 ]
Seifert, Gregory J. [5 ]
Lichter, Patrick A. [1 ]
Hedin, Daniel S. [5 ]
Panescu, Dorin [6 ]
机构
[1] Koronis Biomed Technol Inc, Maple Grove, MN 55369 USA
[2] Cedars Sinai Med Ctr, Cedars Sinai Heart Ctr, Los Angeles, CA 90048 USA
[3] Univ Minnesota, Dept Biomed Engn, Minneapolis, MN 55455 USA
[4] St Jude Med Speakers Bur, Yokohama, Kanagawa, Japan
[5] Adv Med Elect Corp, Maple Grove, MN 55369 USA
[6] Adv Cardiac Therapeut, Santa Clara, CA 95054 USA
来源
2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2015年
关键词
DEFIBRILLATOR LEAD; SILICONE LEADS; RIATA; INSULATION; CABLES;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Abrasion-induced insulation breach is a common failure mode of silicone-body, transvenous, implantable cardioverter defibrillator leads. It is caused either by external compression or internal motion of conducting cables. The present method of monitoring lead integrity measures low frequency conductor impedance. It cannot detect insulation failures until both the silicone lead body and inner fluoropolymer insulation have been breached completely, exposing conductors directly to blood or tissue. Even then the resistance changes are usually swamped by the baseline values. Thus the first clinical presentation may be either failure to deliver a life-saving shock or painful, inappropriate shocks in normal rhythm. We have previously presented a method for identifying early lead failure based on high frequency transmission line impedance measurements. That work used fresh leads in a liquid simulation bath; we have now demonstrated similar effects in leads soaked for 32 days and hence with saline-saturated silicone lead bodies.
引用
收藏
页码:5667 / 5671
页数:5
相关论文
共 50 条
  • [1] RIATA ICD LEAD FAILURE: RESULTS OF THE MANUFACTURERS ANALYSIS OF RETURNED LEADS
    Hauser, Robert G.
    Kallinen, Linda
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E584 - E584
  • [2] ICD Lead Failure Detection through High Frequency Impedance
    Kollmann, Daniel T.
    Swerdlow, Charles D.
    Kroll, Mark W.
    Seifert, Gregory J.
    Lichter, Patrick A.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6487 - 6492
  • [3] Early ICD lead failure in defibrillator systems with multiple leads via cephalic access
    Barbhaiya, Chirag R.
    Niazi, Osama
    Bostrom, Jack
    Patil, Sachi
    Jankelson, Lior
    Bernstein, Scott
    Park, David
    Holmes, Douglas
    Aizer, Anthony
    Chinitz, Larry A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (06) : 1462 - 1469
  • [4] ICD leads:: Design and chronic dysfunctions
    Gradaus, R
    Breithardt, G
    Böcker, D
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (02): : 649 - 657
  • [5] Sprint Fidelis ICD lead failure and the manner of lead implantation
    Malecka, B.
    Zabek, A.
    Lelakowski, J.
    Maziarz, A.
    Bednarek, J.
    Kutarski, A.
    EUROPEAN HEART JOURNAL, 2012, 33 : 540 - 541
  • [6] A new lead locking device for the removal of pacemaker and ICD leads
    Kennergren, C
    Tyers, GFO
    Coates, CW
    Coe, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 116A - 116A
  • [7] Outer insulation failure in a multilumen ICD lead
    Wang, Yuxing
    Zhou, Ying
    Xu, Geng
    ACTA CARDIOLOGICA, 2013, 68 (04) : 439 - 441
  • [8] Detection of Transvenous Pacemaker and ICD Lead Vegetations
    Koneru, Jayanthi N.
    Ellenbogen, Kenneth A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (13) : 1406 - 1408
  • [9] Cephalic access with multiple leads may increase the risk of early ICD lead failure. Time to question the dogma?
    Syska, Pawel
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (06) : 1470 - 1471
  • [10] Long-term performance data of modern ICD leads compared to older ICD lead models
    Kleemann, T.
    Nonnenmacher, F.
    Kouraki, K.
    Strauss, M.
    Werner, N.
    Zahn, R.
    EUROPEAN HEART JOURNAL, 2018, 39 : 1026 - 1026