Pre-heating of components in cemented total hip arthroplasty

被引:13
|
作者
Jafri, AA
Green, SM
Partington, PF
McCaskie, AW
Muller, SD
机构
[1] Univ Durham, Sch Engn, Durham DH1 3LE, England
[2] Wansbeck Gen Hosp, Ashington NE63 9JJ, Northd, England
来源
关键词
D O I
10.1302/0301-620X.86B8.14660
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fatigue fractures which originate at stress-concentrating voids located at the implantcement interface are a potential cause of septic loosening of cemented femoral components. Heating of the component to 44degreesC is known to reduce the porosity of the cement-prosthesis interface. The temperature of the cement-bone interface was recorded intral-operatively as 32.3degreesC. A simulated femoral model was devised to study the effect of heating of the component on the implant-cement interface. Heating of the implant and vacuum mixing have a synergistic effect on the porosity of the implant-cement interface, and heating also reverses the gradients of microhardness in the mantle. Heating of the implant also reduces porosity at the interface depending on the temperature. A minimum difference in temperature between the implant and the bone of 3degreesC was required to produce this effect. The optimal difference was 7degreesC, representing a balance between maximal reduction of porosity and an increased risk of thermal injury. Using contemporary cementing techniques, heating the implant to 40degreesC is recommended to produce an optimum effect.
引用
收藏
页码:1214 / 1219
页数:6
相关论文
共 50 条
  • [1] Analysis of Femoral Components of Cemented Total Hip Arthroplasty
    Singh S.
    Harsha A.P.
    Singh, Shantanu (shant0602@ufl.edu), 1600, Springer (97): : 113 - 120
  • [2] Effects of Cemented Hip Stem Pre-heating on Stem Push-out Strength
    Wilairatana, Vajara
    Pirot, Chatchawan
    Limpaphayom, Noppachart
    ORTHOPAEDIC SURGERY, 2015, 7 (03) : 261 - 265
  • [3] Revision of Cemented Total Hip Arthroplasty with Cementless Components in Three Dogs
    Torres, Bryan T.
    Budsberg, Steven C.
    VETERINARY SURGERY, 2009, 38 (01) : 81 - 86
  • [4] Cemented revision of failed uncemented femoral components of total hip arthroplasty
    Davis, CM
    Berry, DJ
    Harmsen, WS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (07): : 1264 - 1269
  • [5] Effects of pre-cooling and pre-heating procedures on cement polymerisation and thermal osteonecrosis in cemented hip replacements
    Talbot, JC
    Shaw, DL
    MEDICAL ENGINEERING & PHYSICS, 2005, 27 (05) : 439 - 439
  • [6] Effects of pre-cooling and pre-heating procedures on cement polymerization and thermal osteonecrosis in cemented hip replacements
    Li, CD
    Schmid, S
    Mason, J
    MEDICAL ENGINEERING & PHYSICS, 2003, 25 (07) : 559 - 564
  • [7] A comparison of collared and collarless femoral components in primary cemented total hip arthroplasty
    Meding, JB
    Ritter, MA
    Keating, EM
    Faris, PM
    Edmondson, K
    JOURNAL OF ARTHROPLASTY, 1999, 14 (02): : 123 - 130
  • [8] Survival of cemented short Exeter femoral components in primary total hip arthroplasty
    van Veghel, Mirthe H. W.
    van Der Koelen, Remy E.
    Hannink, Gerjon
    Schreurs, B. W.
    Rijnen, Wim H. C.
    BONE & JOINT JOURNAL, 2024, 106B (03): : 137 - 142
  • [9] Cemented total hip arthroplasty in Germany - An update
    Keutzer, J
    Schneider, M
    Schlegel, U
    Ewerbeck, V
    Breusch, SJ
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2005, 143 (01): : 48 - 55
  • [10] Primary total hip arthroplasty: Cemented or cementless
    DeBoer, DK
    TOPICS IN GERIATRIC REHABILITATION, 1996, 12 (01) : 1 - 8