Technical aspects of intravascular pressure monitoring during donor care

被引:2
|
作者
Powner, David J. [1 ]
John, Ambili M. [1 ]
机构
[1] Univ Texas Hlth Sci Ctr Houston Med Sch, Vivian L Smith Inst Neurol Res, Houston, TX USA
关键词
D O I
10.7182/prtr.20.1.e416m5337302r242
中图分类号
R61 [外科手术学];
学科分类号
摘要
Many biological signals must be measured and interpreted accurately to titrate therapy properly during donor care. Although the technological aspects of intravascular pressure monitoring are usually delegated to bedside nursing colleagues, organ procurement coordinators should be familiar with those devices and methods. The equipment, supplies, and procedures used for arterial and central venous pressure monitoring are reviewed. Transducer leveling and zeroing plus maintenance of the hydraulic tubing system between the transducer and bedside monitor are especially important. These variables may greatly influence the accuracy of the displayed pressures and, therefore, must be considered during donor assessment as treatment is considered. (Progress in Transplantation. 2010;20:22-27)
引用
收藏
页码:22 / 27
页数:6
相关论文
共 50 条
  • [1] Technical aspects of bedside respiratory monitoring of transpulmonary pressure
    Mojoli, Francesco
    Torriglia, Francesca
    Orlando, Anita
    Bianchi, Isabella
    Arisi, Eric
    Pozzi, Marco
    ANNALS OF TRANSLATIONAL MEDICINE, 2018, 6 (19)
  • [2] New aspects of technical testing of intravascular stents
    Sergienko, V. I.
    Martynov, A. K.
    Petryaikin, A. V.
    Koshurnikov, D. S.
    Fadeev, A. A.
    Nikolaev, D. A.
    Karmazanovskii, G. G.
    Osipova, N. Yu.
    Fedorov, V. D.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2007, 144 (03) : 482 - 485
  • [3] New aspects of technical testing of intravascular stents
    V. I. Sergienko
    A. K. Martynov
    A. V. Petryaikin
    D. S. Koshurnikov
    A. A. Fadeev
    D. A. Nikolaev
    G. G. Karmazanovskii
    N. Yu. Osipova
    V. D. Fedorov
    Bulletin of Experimental Biology and Medicine, 2007, 144 : 482 - 485
  • [4] Intravascular pressure monitoring system
    Schnakenberg, U
    Krüger, C
    Pfeffer, JG
    Mokwa, W
    Bögel, GV
    Günther, R
    Schmitz-Rode, T
    SENSORS AND ACTUATORS A-PHYSICAL, 2004, 110 (1-3) : 61 - 67
  • [5] TECHNICAL AND METHODOLOGICAL ASPECTS OF AMBULATORY BLOOD-PRESSURE MONITORING SYSTEMS
    ZURMANN, J
    HERZ, 1989, 14 (04) : 205 - 213
  • [6] Invasive intravascular hemodynamic monitoring: Technical issues
    Magder, Sheldon
    CRITICAL CARE CLINICS, 2007, 23 (03) : 401 - +
  • [7] Intracranial pressure monitoring during stereoelectroencephalography implantation: a technical note
    Nagahama, Yasunori
    Alexander, Allyson L.
    O'Neill, Brent R.
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2022, 29 (04) : 454 - 457
  • [8] Technical aspects of intracranial pressure monitoring by subarachnoid method in severe head injury
    Dantas, VP
    Falcao, ALE
    Sardinha, LAD
    Facure, JJ
    Araújo, S
    Terzi, RGG
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2001, 59 (04) : 895 - 900
  • [9] Central Venous Pressure Monitoring during Living Donor Hepatectomies
    Ramirez, Laura
    Beltran, Andres G.
    Franco Gruntorad, German A.
    Santana, Yimy A.
    Tellez, Manuela
    Montes, Felix R.
    ANESTHESIA AND ANALGESIA, 2021, 132 (5S_SUPPL): : 506 - 508
  • [10] TECHNICAL ASPECTS OF CELL COLLECTION - DONOR CONSIDERATIONS
    HUESTIS, DW
    CLINICAL ONCOLOGY MONOGRAPHS, 1983, 2 (03): : 529 - 547