Electrochemical sensor based on phospholipid modified glassy carbon electrode - determination of paraquat

被引:28
|
作者
Tomkova, H. [1 ]
Sokolova, R. [2 ]
Opletal, T. [1 ]
Kucerova, P. [1 ]
Kucera, L. [1 ]
Souckova, J. [1 ]
Skopalova, J. [1 ]
Bartak, P. [1 ]
机构
[1] Palacky Univ, Reg Ctr Adv Technol & Mat, Dept Analyt Chem, Fac Sci, 17 Listopadu 12, Olomouc 77146, Czech Republic
[2] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 2155-3, Prague 18223 8, Czech Republic
关键词
Asolectin; Phospholipid; Paraquat; Sensor; Square wave voltammetry; BILAYER-LIPID MEMBRANES; WAVE VOLTAMMETRIC DETERMINATION; PERFORMANCE LIQUID-CHROMATOGRAPHY; ATOMIC-FORCE MICROSCOPY; DOPED DIAMOND ELECTRODE; PASTE ELECTRODE; MASS-SPECTROMETRY; SENSITIVE DETERMINATION; STRIPPING VOLTAMMETRY; CYCLIC VOLTAMMETRY;
D O I
10.1016/j.jelechem.2017.12.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical sensor based on glassy carbon electrode modified with asolectin (mixture of soybean phospholipids) was developed. Properties of phospholipid layer, such as thickness and compactness, were investigated using atomic force microscopy and X-ray photoelectron spectroscopy. Phospholipids completely cover whole surface and the thickness of the layer 7.1 +/- 1.2 nm corresponds to the value of the phospholipid bilayer of cell membranes. Due to the accumulation of paraquat in the phospholipid layer, square wave voltammetry with asolectin modified electrode exhibits three times higher sensitivity, measured as a slope of calibration dependence, and better linearity in comparison to unmodified glassy carbon electrode. Limit of detection 2.2 nmol L-1 and recoveries higher than 88% were achieved in model samples of water. The method was used for determination of paraquat in real sample of river water and results were compared with high performance liquid chromatography and differential pulse voltammetry on hanging mercury drop electrode giving 0.071 +/- 0.010, 0.050 +/- 0.010 and 0.061 +/- 0.008 mu mol L-1, respectively.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [1] A sensitive electrochemical sensor for the determination of carvedilol based on a modified glassy carbon electrode with ordered mesoporous carbon
    Rofouei, Mohammad Kazem
    Khoshsafar, Hamid
    Kalbasi, Roozbeh Javad
    Bagheri, Hasan
    RSC ADVANCES, 2016, 6 (16): : 13160 - 13167
  • [2] Graphene Ink Modified Glassy Carbon Electrode as electrochemical sensor for Galantamine Determination
    Shi, Haobin
    Zheng, Yuhong
    Wu, Mengyao
    Fu, Li
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (02): : 1546 - 1555
  • [3] Facile electrochemical determination of tetrabromobisphenol A based on modified glassy carbon electrode
    Zhao, Qiang
    Zhang, Ke
    Yu, Guangxia
    Wu, Weixiang
    Wei, Xiaoyun
    Lu, Qing
    TALANTA, 2016, 151 : 209 - 216
  • [4] Electrochemical Determination of Paraquat Using Ordered Mesoporous Carbon (CMK-3) Modified Glassy Carbon Electrode
    Rajaram, Rajendran
    Kumar, Sachin
    Ramanujam, Kothandaraman
    Neelakantan, Lakshman
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (08)
  • [5] ELECTROCHEMICAL-BEHAVIOR OF A PHOSPHOLIPID MODIFIED GLASSY-CARBON ELECTRODE
    CHASTEL, O
    LOPEZ, V
    KAUFFMANN, JM
    PATRIARCHE, GJ
    ANALUSIS, 1989, 17 (10) : 581 - 586
  • [6] Use of guanine-modified glassy carbon electrode as an electrochemical sensor for the determination of paracetamol
    Islamoglu, Nesim
    Mulazimoglu, Ayen Demir
    BANGLADESH JOURNAL OF PHARMACOLOGY, 2023, 18 (03) : 97 - 104
  • [7] Fabrication of an Electrochemical Sensor for Determination of Epinephrine Using a Glassy Carbon Electrode Modified with Catechol
    Mazloum-Ardakani, Mohammad
    Alvansaz-Yazdi, Farnaz
    Hosseini-Dokht, Farzaneh
    Khoshroo, Alireza
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2023, 10 (04): : 387 - 394
  • [8] Electrochemical sensor for heparin based on a poly(thionine) modified glassy carbon electrode
    Hong Yu Huo
    Hong Qun Luo
    Nian Bing Li
    Microchimica Acta, 2009, 167 : 195 - 199
  • [9] Electrochemical sensor for heparin based on a poly(thionine) modified glassy carbon electrode
    Huo, Hong Yu
    Luo, Hong Qun
    Li, Nian Bing
    MICROCHIMICA ACTA, 2009, 167 (3-4) : 195 - 199
  • [10] An electrochemical sensor for caffeine at a carbon nanofiber modified glassy carbon electrode
    Tsholofelo I. Sebokolodi
    Dimpo S. Sipuka
    Tebogo R. Tsekeli
    Duduzile Nkosi
    Omotayo A. Arotiba
    Journal of Food Measurement and Characterization, 2022, 16 : 2536 - 2544