Development of noninvasive mechanical tests to monitor fracture healing has been hindered because relationships between bone geometry, measurement conditions, and fracture callus strength are not well understood. Beam theory was used to analyze the effects of fracture length, fracture location, end conditions, and fracture callus stiffness on mechanical properties (resonant frequency, bending stiffness, and torsional stiffness) of healing bone. Actual bone mineral geometry from a human tibia, quantified every 1 mm, was used in the beam analysis. Geometry of the fracture callus segment was uniformly scaled from the values for intact bone. Experimental tests on multisegmented machined rods were used to verify analytical methods. Mechanical properties of the healing bone initially increased very rapidly to 30-70% of the stiffness of intact bone, depending on the configuration. The increases then tapered off dramatically. Lateral bending stiffness was sensitive to changes in callus properties for a larger portion of the healing process than was either torsional stiffness or resonant frequency. Because callus strength increases at half the rate of callus stiffness, measures of whole-bone mechanical properties can provide insight into changes in callus strength until a maximum of less than one-half the strength of intact bone is regained. The analytical method presented is proposed for clinical use to develop individualized models of bone, fracture, and fixation conditions to identify early stages of healing. Because increases in whole-bone mechanical properties are small in the later stages of fracture healing, however, such measures must be used prudently beyond the initial stages.
引用
收藏
页码:691 / 697
页数:7
相关论文
共 15 条
  • [1] THE INFLUENCE OF DICHLOROMETHYLENE BISPHOSPHONATE ON THE HEALING OF A LONG-BONE FRACTURE, COMPOSITION OF BONE-MINERAL AND HISTOLOGY OF BONE IN THE RAT
    HYVONEN, PM
    KARHI, T
    KOSMA, VM
    LIIMOLALUOMA, L
    HANHIJARVI, H
    PHARMACOLOGY & TOXICOLOGY, 1994, 75 (06): : 384 - 390
  • [2] Optimal administration frequency and dose of teriparatide for acceleration of biomechanical healing of long-bone fracture in a mouse model
    Ota, Masahiro
    Takahata, Masahiko
    Shimizu, Tomohiro
    Momma, Daisuke
    Hamano, Hiroki
    Hiratsuka, Shigeto
    Amizuka, Norio
    Hasegawa, Tomoka
    Iwasaki, Norimasa
    JOURNAL OF BONE AND MINERAL METABOLISM, 2019, 37 (02) : 256 - 263
  • [3] Optimal administration frequency and dose of teriparatide for acceleration of biomechanical healing of long-bone fracture in a mouse model
    Masahiro Ota
    Masahiko Takahata
    Tomohiro Shimizu
    Daisuke Momma
    Hiroki Hamano
    Shigeto Hiratsuka
    Norio Amizuka
    Tomoka Hasegawa
    Norimasa Iwasaki
    Journal of Bone and Mineral Metabolism, 2019, 37 : 256 - 263
  • [4] The effect of platelet-rich plasma on fracture healing in long-bone pseudoarthrosis
    Koray Başdelioğlu
    Gökhan Meriç
    Serdar Sargın
    Aziz Atik
    Ali Engin Ulusal
    Devrim Akseki
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 1481 - 1486
  • [5] The effect of platelet-rich plasma on fracture healing in long-bone pseudoarthrosis
    Basdelioglu, Koray
    Meric, Goekhan
    Sargin, Serdar
    Atik, Aziz
    Ulusal, Ali Engin
    Akseki, Devrim
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (08): : 1481 - 1486
  • [6] Numerical and experimental simulation of the effect of long bone fracture healing stages on ultrasound transmission across an idealized fracture
    Gheduzzi, S.
    Dodd, S. P.
    Miles, A. W.
    Humphrey, V. F.
    Cunningham, J. L.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2009, 126 (02): : 887 - 894
  • [7] A Novel Capacitive Measurement Device for Longitudinal Monitoring of Bone Fracture Healing
    Sorriento, Angela
    Chiurazzi, Marcello
    Fabbri, Luca
    Scaglione, Michelangelo
    Dario, Paolo
    Ciuti, Gastone
    SENSORS, 2021, 21 (19)
  • [8] Comments on the study "The effect of platelet-rich plasma on fracture healing in long-bone pseudoarthrosis"
    Bahagotia, Umesh Kumar
    Panwar, Akshay
    Iyer, R. Dinesh
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2021, 31 (06): : 1253 - 1254
  • [9] Comments on the study “The effect of platelet-rich plasma on fracture healing in long-bone pseudoarthrosis”
    Umesh Kumar Bahagotia
    Akshay Panwar
    R. Dinesh Iyer
    European Journal of Orthopaedic Surgery & Traumatology, 2021, 31 : 1253 - 1254
  • [10] Electrical Stimulation for Long-Bone Fracture-Healing: A Meta-Analysis of Randomized Controlled Trials
    Mollon, Brent
    da Silva, Vitor
    Busse, Jason W.
    Einhorn, Thomas A.
    Bhandari, Mohit
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (11): : 2322 - 2330