Validation of a method to measure three-dimensional hip joint kinematics in subjects with femoroacetabular impingement

被引:2
|
作者
Ward, Thomas R. [1 ]
Hussain, Mafruha M. [2 ]
Pickering, Mark [2 ]
Perriman, Diana [1 ]
Burns, A., I [1 ]
Scarvell, Jennie [1 ,3 ]
Smith, Paul N. [1 ,4 ]
机构
[1] Canberra Hosp, Trauma & Orthopaed Res Unit, Bldg 6 Level 1,POB 2, Woden, ACT 2606, Australia
[2] Univ New South Wales, Australian Def Force Acad, Canberra, ACT, Australia
[3] Univ Canberra, Canberra, ACT, Australia
[4] Australian Natl Univ, Canberra, ACT, Australia
关键词
Femoroacetabular impingement; fluoroscopy; hip; image registration; kinematics; OSTEOARTHRITIS; ACCURACY; MOTION;
D O I
10.1177/1120700019883548
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: A kinematic measurement method combining dynamic motion and imaging, which captures the behaviour of the hip at terminal motion, may offer improved diagnostic accuracy and enhance our understanding of the mechanics of femoroacetabular impingement (FAI). Methods: 3 embalmed cadaveric hip/pelvis specimens with implanted Roentgen Stereophotogrammetric Analysis (RSA) beads were mounted on a custom rig and imaged with a fluoroscope in four poses to simulate a clinical impingement examination: in hip extension and in three positions: near impingement, early impingement and late impingement while simulating a flexion/adduction/internal rotation manoeuvre. Hip joint kinematics were measured using 2 methods and compared: RSA (gold standard) and a custom 3-dimensional to 2-dimensional (3D-2D) image registration method which matches 3D models developed from CT to 2D fluoroscopic images. Results: Using RSA as the gold standard, bias and precision of hip joint rotations measured using 3D-2D registration demonstrated maximums of 1.64 degrees and 3.96 degrees, respectively. However, if the single outlier was removed, bias and precision were 0.55 degrees and 1.38 degrees. Bias and precision of translations had maximums of 0.51 mm and 0.77 mm, respectively. Conclusions: This 3D to 2D registration method may offer a clinically useful solution for dynamic assessment of hip impingement. If 5-mm translation and 10 degrees of rotation represent a clinically significant difference in hip kinematics, the method's accuracy of approximately 1 mm displacement and 1 degrees rotation should enable detection of significant clinical differences.
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [1] Three-dimensional computed tomography of the hip in the assessment of femoroacetabular impingement
    Beaulé, PE
    Zaragoza, E
    Motamedi, K
    Copelan, N
    Dorey, FJ
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (06) : 1286 - 1292
  • [2] Noninvasive three-dimensional assessment of femoroacetabular impingement
    Tannast, Moritz
    Kubiak-Langer, Monika
    Langlotz, Frank
    Puls, Marc
    Murphy, Stephen B.
    Siebenrock, Klaus A.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2007, 25 (01) : 122 - 131
  • [3] Development of a three-dimensional detection method of cam deformities in femoroacetabular impingement
    Audenaert, Emmanuel A.
    Baelde, Nick
    Huysse, Wouter
    Vigneron, Lara
    Pattyn, Christophe
    SKELETAL RADIOLOGY, 2011, 40 (07) : 921 - 927
  • [4] A method for three-dimensional evaluation and computer aided treatment of femoroacetabular impingement
    Audenaert, E.
    Vigneron, L.
    Pattyn, C.
    COMPUTER AIDED SURGERY, 2011, 16 (03) : 143 - 148
  • [5] Development of a three-dimensional detection method of cam deformities in femoroacetabular impingement
    Emmanuel A. Audenaert
    Nick Baelde
    Wouter Huysse
    Lara Vigneron
    Christophe Pattyn
    Skeletal Radiology, 2011, 40 : 921 - 927
  • [6] Imaging of the hip joint in femoroacetabular impingement
    Waldt, Simone
    ARTHROSKOPIE, 2019, 32 (02) : 86 - 94
  • [7] Three-Dimensional Assessment of Cam Engagement in Femoroacetabular Impingement
    Audenaert, Emmanuel A.
    Mahieu, Peter
    Pattyn, Christophe
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2011, 27 (02): : 167 - 171
  • [8] Repeat validation of a method to measure in vivo three dimensional hip kinematics using computed tomography and fluoroscopy
    Hossain, Mafruha Mowrin
    Alam, Md. Jahangir
    Pickering, Mark R.
    Ward, Thomas
    Perriman, Diana
    Scarvell, Jennie M.
    Smith, Paul N.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6044 - 6047
  • [9] Impact of femoroacetabular impingement and dysplasia of the hip on hip joint sphericity
    Diaz-Lopez, Reynol A.
    Alonso-Rasgado, M. Teresa
    Jimenez-Cruz, David
    Bailey, Colin G.
    Board, Tim N.
    HIP INTERNATIONAL, 2020, 30 (02) : 195 - 203
  • [10] THREE-DIMENSIONAL GEOMETRIC MORPHOMETRICS AND KINEMATICS OF THEROPOD HIP-JOINT FUNCTION
    Souter, Thibaud
    Abourachid, Anick
    Hutchinson, John
    Baylac, Michel
    JOURNAL OF VERTEBRATE PALEONTOLOGY, 2009, 29 : 184A - 184A