Test-retest repeatability of patterns of brain activation provoked by bladder filling

被引:11
|
作者
Clarkson, Becky D. [1 ]
Tyagi, Shachi [1 ]
Griffiths, Derek J. [1 ]
Resnick, Neil M. [1 ]
机构
[1] Univ Pittsburgh, Div Geriatr Med, Kaufmann Bldg Ste 500,3471 Fifth Ave, Pittsburgh, PA 15213 USA
关键词
fMRI; neuroimaging; reproducibility of results; test-retest reliability; urge; urinary incontinence; women; WHITE-MATTER; MICTURITION; CONTRACTIONS; NIRS;
D O I
10.1002/nau.23153
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveTo assess short-term repeatability of an fMRI protocol widely used to assess brain control of the bladder. fMRI offers the potential to discern incontinence phenotypes as well as the mechanisms mediating therapeutic response. If so, this could enable more targeted efforts to enhance therapy. Such data, however, require excellent test-retest repeatability. MethodsFifty-nine older women (age 60 years) with urgency incontinence underwent two fMRI scans within 5-10min with a concurrent bladder infusion/withdrawal protocol. Activity in three brain regions relevant to bladder control was compared using paired t tests and intra-class correlation. ResultsThere were no statistically significant differences in brain activity between the two consecutive scans in the regions of interest. Intra-class correlation was 0.19 in the right insula, 0.32 in the dorsal anterior cingulate cortex/supplementary motor area, and 0.44 in the medial pre-frontal cortex. Such correlations are considered fair or poor, but are comparable to those from studies of other repeated fMRI tasks. ConclusionsThis is the first evaluation of the repeatability of a bladder fMRI protocol. The technique used provides a framework for comparing different fMRI protocols applied to brain-bladder research. Despite universal patient response to the stimulus, brain response had limited repeatability within individuals. Improvement of the investigational protocol should magnify brain response and reduce variability. These results suggest that although analysis of fMRI data among groups of subjects yields valuable insight into bladder control, fMRI is not yet appropriate for evaluation of the brain's role in continence on an individual level.
引用
收藏
页码:1472 / 1478
页数:7
相关论文
共 50 条
  • [1] Re: Test-Retest Repeatability of Patterns of Brain Activation Provoked by Bladder Filling Editorial Comment
    Wein, Alan J.
    [J]. JOURNAL OF UROLOGY, 2018, 199 (06): : 1404 - 1404
  • [2] Test-retest repeatability of the Strain Index
    Stephens, JP
    Vos, GA
    Stevens, EM
    Moore, JS
    [J]. APPLIED ERGONOMICS, 2006, 37 (03) : 275 - 281
  • [3] Test-retest Repeatability of the Ohio Contrast Cards
    Osman, Mawada
    Njeru, Stevie M.
    Hopkins, Gregory R., II
    Brown, Angela M.
    [J]. OPTOMETRY AND VISION SCIENCE, 2021, 98 (09) : 1070 - 1077
  • [4] Test-retest repeatability in macular retinal oximetry
    Smith, Jennyffer D.
    Bisignano, Kelly
    Harrison, Wendy W.
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024, 107 (06) : 616 - 621
  • [5] Test-Retest Repeatability of Microperimetry at the Border of Deep Scotomas
    Wu, Zhichao
    Jung, Chang J.
    Ayton, Lauren N.
    Luu, Chi D.
    Guymer, Robyn H.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (04) : 2606 - 2611
  • [6] Test-Retest Repeatability of Human Gestures in Manipulation Tasks
    Digo, Elisa
    Caselli, Elena
    Polito, Michele
    Antonelli, Mattia
    Gastaldi, Laura
    Pastorelli, Stefano
    [J]. APPLIED SCIENCES-BASEL, 2023, 13 (13):
  • [7] Test-retest repeatability of the pattern electroretinogram and flicker electroretinogram
    Resende, Arthur F.
    Sanvicente, Carina T.
    Eshraghi, Hamoon
    Garcia, Alberto
    Pickel, Kassandra
    Zhang, Qiang
    Waisbourd, Michael
    Katz, L. Jay
    [J]. DOCUMENTA OPHTHALMOLOGICA, 2019, 139 (03) : 185 - 195
  • [8] Test-retest repeatability of quantitative bone SPECT/CT
    Yamane, Tomohiko
    Fukushima, Kenji
    Shirotake, Suguru
    Nishimoto, Koshiro
    Okabe, Takashi
    Oyama, Masafumi
    Seto, Akira
    Kuji, Ichiei
    [J]. ANNALS OF NUCLEAR MEDICINE, 2021, 35 (03) : 338 - 346
  • [9] Test-retest Repeatability of Myocardial SPECT Perfusion Imaging
    Ali, I.
    Ruddy, T. D.
    Alghamdi, A.
    Wells, R. G.
    [J]. EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S68 - S68
  • [10] Test-retest repeatability of distortion product otoacoustic emissions
    Wagner, Wolfgang
    Heppelmann, Guido
    Vonthein, Reinhard
    Zenner, Hans Peter
    [J]. EAR AND HEARING, 2008, 29 (03): : 378 - 391