Assessing the Readjustable Sling Procedure (Remeex System) for Female Stress Urinary Incontinence With Detrusor Underactivity

被引:11
|
作者
Ko, Kwang Jin [1 ]
Suh, Yoon Seok [1 ]
Sung, Hyun Hwan [1 ]
Ryu, Gyu Ha [2 ]
Lee, Munjae [3 ]
Lee, Kyu-Sung [1 ,3 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Urol, 50 Irwon Ro, Seoul 06351, South Korea
[2] Samsung Med Ctr, Off R&D Strategy & Planning, Seoul, South Korea
[3] Sungkyunkwan Univ, SAIHST, Dept Med Device Management & Res, Seoul, South Korea
关键词
Female; Midurethral Sling; Urinary Incontinence; Stress; QUALITY-OF-LIFE; TRANSOBTURATOR; COMPLICATIONS; PREVALENCE; TAPE;
D O I
10.5213/inj.1732682.341
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Many surgeons worry about postoperative voiding problems in patients with stress urinary incontinence (SUI) and detrusor underactivity (DU). This study hypothesized that adjusting the tension after surgery would benefit patients with DU, and therefore researchers evaluated the outcomes and quality of life of women with SUI and DU who underwent the readjustable sling procedure (Remeex). Methods: The medical records of 27 patients who were treated with the Remeex system for SUI and DU between 2007 and 2013 were retrospectively analyzed. The incontinence visual analogue scale (I-VAS), incontinence quality of life questionnaire (I-QOL) and the Sandvik incontinence severity index (ISI) were used to evaluate the efficacy of the Remeex system both prior to surgery and at the last visit after surgery. The treatment was considered successful if there was no urine leakage based on the Sandvik questionnaire. Results: The mean follow-up period was 38.0 months (range, 1-75 months), and the treatment success rate was 81.5%. Despite no urine leakage, 7 patients wanted the Remeex system to be removed due to persistent postoperative urinary retention within a year of surgery. One patient underwent a long-term adjustment under local anesthesia 6 years after the initial surgery. The I-VAS, ISI and all domains of the I-QOL scores improved significantly postoperatively and the maximum flow rate decreased significantly after the procedure. However, the postvoid residual did not change significantly. Conclusions: The Remeex system provided a good cure rate and improved the quality of life of women with SUI and DU. Therefore, the Remeex system should be considered as a treatment option for female patients with concomitant SUI and DU.
引用
收藏
页码:116 / 120
页数:5
相关论文
共 50 条
  • [1] Efficacy and safety of a readjustable midurethral sling (Remeex system) for stress urinary incontinence with female voiding dysfunction
    Chung, Jae-Wook
    Yoo, Eun Sang
    INVESTIGATIVE AND CLINICAL UROLOGY, 2017, 58 (02) : 127 - 133
  • [2] LONG TERM FOLLOW-UP OF READJUSTABLE URETHRAL SLING PROCEDURE (REMEEX SYSTEM®) FOR MALE STRESS URINARY INCONTINENCE
    Kim, Jang Hwan
    Kim, Joon Chul
    Seo, Ju Tae
    NEUROUROLOGY AND URODYNAMICS, 2011, 30 (02) : 209 - 209
  • [3] ADJUSTABLE SLING (TRT REMEEX FEMALE SYSTEM®): A SALVAGE PROCEDURE FOR RECURRENT FEMALE STRESS URINARY INCONTINENCE
    Pettit, P.
    Chen, A.
    Wechter, M. E.
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2010, 21 : S329 - S330
  • [4] ADJUSTABLE SLING (TRT REMEEX FEMALE SYSTEM®): A SALVAGE PROCEDURE FOR RECURRENT FEMALE STRESS URINARY INCONTINENCE
    Pettit, P.
    Chen, A.
    Wechter, M. E.
    NEUROUROLOGY AND URODYNAMICS, 2010, 29 (06) : 1133 - 1134
  • [5] Midterm Efficacy and Complications of Readjustable Midurethral Sling (Remeex System) in Female Stress Urinary Incontinence With Recurrence or Intrinsic Sphincter Deficiency
    Park, Bong Hee
    Kim, Joon Chul
    Kim, Hyun Woo
    Kim, Young Ho
    Choi, Jong Bo
    Lee, Dong Hwan
    UROLOGY, 2015, 85 (01) : 79 - 84
  • [6] Mid-term results of the Remeex® readjustable sling for female complex stress urinary incontinence and sonographic hypomobile urethra
    Ros, Cristina
    Escura, Silvia
    Angles-Acedo, Sonia
    Larroya, Marta
    Bataller, Eduardo
    Amat, Lluis
    Sanchez, Emilia
    Espuna-Pons, Montserrat
    Carmona, Francisco
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2022, 33 (04) : 903 - 910
  • [7] A readjustable implant to treat stress urinary incontinence:: Remeex system (TRT)
    Cabrera, J.
    Bravo, Fernandez, I
    Gonzalez, Enguita C.
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2007, 18 : S35 - S35
  • [8] Suburethral readjustable sling (ReMeEx ®) in male urinary incontinence:: Surgical technique
    Sousa, A
    JOURNAL OF UROLOGY, 2005, 173 (04): : 366 - 367
  • [9] Mid-term results of the Remeex® readjustable sling for female complex stress urinary incontinence and sonographic hypomobile urethra
    Cristina Ros
    Sílvia Escura
    Sònia Anglès-Acedo
    Marta Larroya
    Eduardo Bataller
    Lluís Amat
    Emília Sánchez
    Montserrat Espuña-Pons
    Francisco Carmona
    International Urogynecology Journal, 2022, 33 : 903 - 910
  • [10] Readjustable Sling Procedure for the Treatment of Female Stress Urinary Incontinence with Intrinsic Sphincter Deficiency: Preliminary Report
    Yoo, Dong Hoon
    Noh, Joon Hwa
    KOREAN JOURNAL OF UROLOGY, 2010, 51 (06) : 420 - 425