Development of an implantable small right ventricular assist device

被引:4
|
作者
Yoshikawa, M
Nakata, K
Takano, T
Maeda, T
Glueck, J
Murabayashi, S
Schima, H
Wolner, E
Nosé, Y
机构
[1] Baylor Coll Med, Dept Surg, Houston, TX 77030 USA
[2] Univ Vienna, A-1010 Vienna, Austria
关键词
D O I
10.1097/00002480-200005000-00019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Currently, at least two permanent implantable left ventricular assist devices (LVADs) are used clinically. Unfortunately, there is no small implantable right ventricular assist device (RVAD) available, even though at least 25-30% of this patient population has right ventricular failure. If a small implantable RVAD were available, biventricular assist could support patients with right ventricular failure. A small atraumatic and antithrombogenic RVAD is being developed to meet this clinical need. This small centrifugal blood pump, the Gyro PI pump, is 6.5 cm in diameter and 4.6 cm in height and has three unique characteristics to prevent thrombus formation: (1) the double pivot bearing and magnetic coupling system enable this pump to be completely sealless; (2) the secondary Vanes at the bottom of the impeller accelerate the blood flow and prevent blood stagnation; and (3) the eccentric inlet port enables the top female bearing to be embedded into the top housing and decrease blood cell trauma. The inflow conduit consists of a wire reinforced tube and a hat-shaped tip that is biolized with gelatin to create a thrombus resistant material. This conduit is directly implanted into the right ventricle, and the outflow conduit is anastomosed to the PA. The pump can be implanted inside the abdominal wall or in the thoracic cavity. Biocompatibility of this pump was proved in two calves by thrombus free implantation as an LVAD for 284 days and 200 days. Two RVAD implantations were conducted, aiming for 1-month system feasibility studies. During the month, the RVADs operated satisfactorily without any thromboembolic incident. No blood clots or abnormal findings were seen inside the pump, nor were there abnormal findings in the explanted lungs except for small areas of atelectasis. The pump flow was 3.02 +/- 0.38 L/min in calf 1 and 3.75 +/- 1.18 L/min in calf 2. The power requirement was 7.28 +/- 0.43W for calf 1 and 14.52 +/- 3.93W for calf 2. The PaO2 was 72.0 +/- 3.60 mm Hg (calf 1) and 72.0 +/- 7.63 mm Hg (calf 2); PaCO2 was 38.3 +/- 2.17 mm Hg (calf 1) and 34.7 +/- 1.95 mm Hg (calf 2); and SaO(2) was 94.1 +/- 1.37% (calf 1) and 95.0 +/- 1.95% (calf 2). Cas exchange via the lungs was maintained. These studies indicate that the Gyro PI pump is suitable as a single implantable RVAD, and is a feasible RVAD as a part of a BiVAD system in terms of pump performance and thrombus resistance.
引用
收藏
页码:338 / 343
页数:6
相关论文
共 50 条
  • [1] Development of a small implantable right ventricular assist device
    Fukamachi, K
    Horvath, DJ
    Massiello, AL
    Ootaki, Y
    Kamohara, K
    Akiyama, M
    Zahr, F
    Kopcak, MW
    Dessoffy, R
    Chen, JF
    Benefit, S
    Golding, LAR
    [J]. ASAIO JOURNAL, 2005, 51 (06) : 730 - 735
  • [2] Development of implantable right ventricular assist device
    Furukawa, K
    Motomura, T
    Hata, A
    Asai, T
    Yuri, K
    Iwahashi, H
    Tanaka, A
    Nosé, Y
    [J]. ASAIO JOURNAL, 2004, 50 (06) : 543 - 549
  • [3] Right ventricular failure after left ventricular assist device implantation:: The need for an implantable right ventricular assist device
    Furukawa, K
    Motomura, T
    Nosé, Y
    [J]. ARTIFICIAL ORGANS, 2005, 29 (05) : 369 - 377
  • [4] Right ventricular assist device with membrane oxygenator support for right ventricular failure following implantable left ventricular assist device placement
    Leidenfrost, Jeremy
    Prasad, Sunil
    Itoh, Akinobu
    Lawrance, Christopher P.
    Bell, Jennifer M.
    Silvestry, Scott C.
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (01) : 73 - 77
  • [5] Development of Miniature, Implantable Pediatric Ventricular Assist Device
    Wearden, P. D.
    Snyder, T. A.
    Stanfield, J. R.
    Coghill, P.
    Crompton, D.
    Olia, S. E.
    Ye, S.
    Kameneva, M. V.
    Wagner, W. R.
    Long, J. W.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S163 - S163
  • [6] DEVELOPMENT OF AN IMPLANTABLE LEFT-VENTRICULAR ASSIST DEVICE
    LIAPIS, CD
    LEVINE, FH
    NUGENT, WC
    KYO, S
    TSAI, CH
    SINGH, PI
    ADAMS, B
    PETSCHEK, H
    AUSTEN, WG
    BUCKLEY, MJ
    [J]. SURGICAL FORUM, 1981, 32 : 244 - 246
  • [7] Liberal Right Ventricular Assist Device Extracorporeal Membrane Oxygenation Support for Right Ventricular Failure after Implantable Left Ventricular Assist Device Placement
    Fischer, Quentin
    Kirsch, Matthias
    [J]. ASAIO JOURNAL, 2018, 64 (06) : 741 - 747
  • [8] Liberal right ventricular assist device extracorporeal membrane oxygenation support for right ventricular failure following implantable left ventricular assist device placement
    Fischer, Q. Quentin
    Kirsch, M.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2017, 19 : 460 - 460
  • [9] Outcome of unplanned right ventricular assist device support for severe right heart failure after implantable left ventricular assist device insertion
    Takeda, Koji
    Naka, Yoshifumi
    Yang, Jonathan A.
    Uriel, Nir
    Colombo, Paolo C.
    Jorde, Ulrich P.
    Takayama, Hiroo
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (02): : 141 - 148
  • [10] Implantable Continuous-Flow Right Ventricular Assist Device: Lessons Learned in the Development of a Cleveland Clinic Device
    Fukamachi, Kiyotaka
    Shiose, Akira
    Massiello, Alex L.
    Horvath, David J.
    Golding, Leonard A. R.
    Lee, Sangjin
    Starling, Randall C.
    [J]. ANNALS OF THORACIC SURGERY, 2012, 93 (05): : 1746 - 1752