Stopped-flow fluorescence resonance energy transfer for analysis of nucleosome dynamics

被引:22
|
作者
Tims, Hannah S. [1 ]
Widom, Jonathan [1 ]
机构
[1] Northwestern Univ, Dept Biochem Mol Biol & Cell Biol, Evanston, IL 60208 USA
关键词
chromatin; histones; LexA protein; DNA; nucleosome reconstitution; FRET; kinetics; Cy-dye labeling; conformational dynamics; site exposure;
D O I
10.1016/j.ymeth.2007.01.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Macromolecular assemblies and machines undergo large-scale conformational changes as essential features of their normal function. Modern stopped-flow instrumentation and biotechnology combine to provide a powerful tool for characterizing the rates and natures of these conformational changes. Standard commercially available instruments provide extraordinary sensitivity and speed, allowing analysis of millisecond or longer timescale processes, with concentrations as low as a few nanomolar and volumes of just a few hundred microliters. One can now place specific dyes anywhere desired on a nucleic acid, and often on a protein as well. This ability allows the use of fluorescence resonance energy transfer experiments for detailed conformational analyses, even as the system is evolving rapidly over time following the initiation of a reaction. This approach is ideally suited for analysis of intrinsic properties of chromatin and of the machines that control chromatin assembly, disassembly, and function. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:296 / 303
页数:8
相关论文
共 50 条
  • [1] Fluorescence stopped-flow analysis of ClpAPA assembly
    不详
    [J]. EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2005, 34 (06): : 724 - 724
  • [2] Conformational dynamics of DNA repair enzymes revealed by fluorescence stopped-flow analysis
    Fedorova, O. S.
    [J]. FEBS JOURNAL, 2013, 280 : 151 - 151
  • [3] Kinetic study of S-griseus aminopeptidase by stopped-flow fluorescence energy transfer
    Yu, HC
    Lin, WY
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1998, 45 (01) : 17 - 22
  • [4] Stopped-flow fluorescence polarization immunoassay
    Gómez-Hens, A
    Aguilar-Caballos, MP
    [J]. COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2003, 6 (03) : 177 - 182
  • [5] FLUORESCENCE LIFETIME RESOLVED STOPPED-FLOW FLUOROMETER
    SLAGLE, SP
    GRATTON, E
    VANDEVEN, M
    MANTULIN, WW
    [J]. FASEB JOURNAL, 1992, 6 (01): : A178 - A178
  • [6] Nucleosome Dynamics as Studied by Single-pair Fluorescence Resonance Energy Transfer: A Reevaluation
    Miroslav Tomschik
    Ken van Holde
    Jordanka Zlatanova
    [J]. Journal of Fluorescence, 2009, 19 : 53 - 62
  • [7] Nucleosome Dynamics as Studied by Single-pair Fluorescence Resonance Energy Transfer: A Reevaluation
    Tomschik, Miroslav
    van Holde, Ken
    Zlatanova, Jordanka
    [J]. JOURNAL OF FLUORESCENCE, 2009, 19 (01) : 53 - 62
  • [8] Conformational Dynamics of Biopolymers in the Course of Their Interaction: Multifaceted Approaches to the Analysis by the Stopped-Flow Technique with Fluorescence Detection
    Kuznetsov, Nikita A.
    [J]. PHOTONICS, 2023, 10 (09)
  • [9] A concept of an electron transfer stopped-flow method
    Oyama, M
    Higuchi, T
    Okazaki, S
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2000, 2 (10) : 675 - 678
  • [10] A stopped-flow fluorescence study of the native and modified lysozyme
    Khalifeh, Khosrow
    Ranjbar, Bijan
    Khajeh, Khosro
    Naderi-Manesh, Hossein
    Sadeghi, Mehdi
    Gharavi, Sara
    [J]. BIOLOGIA, 2007, 62 (03) : 258 - 264