Accuracy of a smartphone pedometer application according to different speeds and mobile phone locations in a laboratory context

被引:27
|
作者
Presset, Bastien [1 ]
Laurenczy, Balazs [2 ]
Malatesta, Davide [1 ]
Barral, Jerome [1 ]
机构
[1] Univ Lausanne, Inst Sport Sci, Quartier UNIL Ctr, Batiment Synathlon, CH-1015 Lausanne, Switzerland
[2] Swiss Fed Inst Technol, Sci IT Serv, Weinbergstr 11, CH-8001 Zurich, Switzerland
关键词
Measurement; Pedometry; Physical activity; Public health; ELECTRONIC PEDOMETERS; PHYSICAL-ACTIVITY; HEALTH; VALIDITY; DISTANCE; WALKING; TREADMILL; OBESITY; STEPS;
D O I
10.1016/j.jesf.2018.05.001
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background: The purpose of this study was to compare the accuracy of a smartphone application and a mechanical pedometer for step counting at different walking speeds and mobile phone locations in a laboratory context. Methods: Seventeen adults wore an iPphone6 (c) with Runtastic Pedometer (c) application (RUN), at 3 different locations (belt, arm, jacket) and a pedometer (YAM) at the waist. They were asked to walk on an instrumented treadmill (reference) at various speeds (2, 4 and 6 km/h). Results: RUN was more accurate than YAM at 2 km/h (p < 0.05) and at 4 km/h (p = 0.03). At 6 km/h the two devices were equally accurate. The precision of YAM increased with speed (p < 0.05), while for RUN, the results were not significant but showed a trend (p = 0.051). Surprisingly, YAM underestimates the number of step by 60.5% at 2 km/h. The best accurate step counting (0.7% mean error) was observed when RUN is attached to the arm and at the highest speed. Conclusions: RUN pedometer application could be recommended mainly for walking sessions even for low walking speed. Moreover, our results confirm that the smartphone should be strapped close to the body to discriminate steps from noise by the accelerometers (particularly at low speed). (C) 2018 The Society of Chinese Scholars on Exercise Physiology and Fitness. Published by Elsevier (Singapore) Pte Ltd.
引用
收藏
页码:43 / 48
页数:6
相关论文
共 32 条
  • [1] Accuracy of piezoelectric pedometer step counts in different wearing locations
    Cruz, Joana
    Brooks, Dina
    Marques, Alda
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [2] Accuracy Of An Electronic Pedometer At Three Different Self-selected Walking Speeds
    Wheeler, Amanda D.
    Dvorak, Leah
    Nelson, Reid
    Zalewski, Kathyrn
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S22 - S22
  • [3] Accuracy of a Commercially Available Pedometer When Worn at Four Different Locations on the Body
    Smith, Kimberly A.
    Sieczkowski, Ashley
    Murberger, Lauren
    Secich, Jacob
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 132 - 132
  • [4] Modeling Pervasive Context-aware Mobile Phone Application
    Getahun, Fekade
    Abebe, Berhanu
    [J]. 2015 11TH INTERNATIONAL CONFERENCE ON SIGNAL-IMAGE TECHNOLOGY & INTERNET-BASED SYSTEMS (SITIS), 2015, : 270 - 277
  • [5] Spatial Accuracy Evaluation for Mobile Phone Location Data With Consideration of Geographical Context
    Song, Xiaoqing
    Long, Yi
    Zhang, Ling
    Rossiter, David G.
    Liu, Fengyuan
    Jiang, Wei
    [J]. IEEE ACCESS, 2020, 8 : 221176 - 221190
  • [6] Diagnostic accuracy of a novel mobile phone application in monitoring atrial fibrillation
    Rozen, G.
    Vaid, J.
    Hosseini, S. M.
    Rafael, A.
    Roka, A.
    Kaadan, I.
    Poh, M. Z.
    Heist, E. K.
    Ruskin, J. N.
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 : 451 - 452
  • [7] Smartphone based blood pressure measurement: accuracy of the OptiBP mobile application according to the AAMI/ESH/ISO universal validation protocol
    Degott, Jean
    Ghajarzadeh-Wurzner, Arlene
    Hofmann, Gregory
    Proenca, Martin
    Bonnier, Guillaume
    Lemkaddem, Alia
    Lemay, Mathieu
    Christen, Urvan
    Knebel, Jean-Francois
    Durgnat, Virginie
    Burnier, Michel
    Wuerzner, Gregoire
    Schoettker, Patrick
    [J]. BLOOD PRESSURE MONITORING, 2021, 26 (06) : 441 - 447
  • [8] Smartphone based blood pressure measurement: accuracy of the OptiBP mobile application according to the AAMI/ESH/ISO universal validation protocol
    Jean, Degott
    Arlene, Ghajarzadeh-Wurzner
    Gregory, Hofmann
    Martin, Proenca
    Guillaume, Bonnier
    Alia, Lemkaddem
    Mathieu, Lemay
    Urvan, Christen
    Jean-Francois, Knebel
    Virginie, Durgnat
    Michel, Burnier
    Gregoire, Wuerzner
    Patrick, Schoettker
    [J]. SWISS MEDICAL WEEKLY, 2021, 151 : 9S - 10S
  • [9] Changes in Urination According to the Sound of Running Water Using a Mobile Phone Application
    Kwon, Whi-An
    Kim, Sung Han
    Kim, Sohee
    Joung, Jae Young
    Chung, Jinsoo
    Lee, Kang Hyun
    Lee, Sang-Jin
    Seo, Ho Kyung
    [J]. PLOS ONE, 2015, 10 (05):
  • [10] Diagnostic Accuracy of a Novel Mobile Phone Application for the Detection and Monitoring of Atrial Fibrillation
    Rozen, Guy
    Vaid, Jeena
    Hosseini, Seyed Mohammadreza
    Kaadan, M. Ihsan
    Rafael, Allon
    Roka, Attila
    Poh, Yukkee C.
    Poh, Ming-Zher
    Heist, Edwin Kevin
    Ruskin, Jeremy Neil
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2018, 121 (10): : 1187 - 1191