Neutral Current Estimation for Multi-grounded Concentric Neutral Cable System

被引:0
|
作者
Yong, Jing [1 ]
Yu, Kan [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 630044, Peoples R China
关键词
Concentric neutral cable; Load imbalance; Neutral current;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Concentric neutral cable system is a most popular practice in distribution systems of North America. Because of the special structure of this type of cable, the concentric neutral conductor serves as a current-carrying conductor and the neutral current can't be measured directly. The potential over loading of neutral conductor may result in cable over-heating. In order to understand the neutral current distribution along the cable, especially for multi-grounded neutral cable system, this paper presents a method to estimate the neutral current by the known three phase currents only. The impacts of each system parameters on the neutral current are also investigated.
引用
收藏
页码:636 / 639
页数:4
相关论文
共 50 条
  • [1] Shielding effect of multi-grounded neutral wire in the distribution system
    Wang, Yunfei
    Acharya, Janak
    Xu, Wilsun
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2011, 21 (01): : 624 - 634
  • [2] A New Method to Monitor the Primary Neutral Integrity in Multi-Grounded Neutral Systems
    Xie, Xiangmin
    Sun, Yuanyuan
    Long, Xun
    Zhang, Bingwei
    ENERGIES, 2017, 10 (03)
  • [3] Narrowband PLC Channel Attenuation Due to a Multi-Grounded Neutral
    Lima, Guilherme S.
    De Conti, Alberto
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (02) : 639 - 650
  • [4] Impact of Neutral Current on Concentric Cable Overloading
    Feng, Wei
    Kou, Xiao
    Zhang, Qiwei
    Li, Fangxing
    2018 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2018,
  • [5] Methodology to Determine Ground Potential Rise in Multi-Grounded Neutral Distribution System with Distributed Generation
    Yun, Sangwon
    Jung, Jaesung
    2021 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2021,
  • [6] Ground potential rise of multi-grounded neutral and shield wires in joint systems
    Acharya, Janak
    Xu, Wilsun
    ELECTRIC POWER SYSTEMS RESEARCH, 2010, 80 (09) : 1074 - 1081
  • [7] Effect of the multi-grounded neutral on the lightning induced voltages in an overhead power line
    Paulino, Jose Osvaldo S.
    Boaventura, Wallace C.
    Barbosa, Celio Fonseca
    2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2016,
  • [8] Analysis of high neutral current in three-phase four-wire multi-grounded distribution feeders
    Chang, GW
    Chiu, MJ
    Lee, KS
    Hsu, YF
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 531 - 535
  • [9] Analysis of multi-grounded four-wire distribution systems considering the neutral grounding
    Chen, TH
    Yang, WC
    IEEE TRANSACTIONS ON POWER DELIVERY, 2001, 16 (04) : 710 - 717
  • [10] Analysis of multi-grounded four-wire distribution systems considering the neutral grounding
    Chen, TH
    Yang, WC
    PICA 2001: 22ND IEEE POWER ENGINEERING SOCIETY INTERNATIONAL CONFERENCE ON POWER INDUSTRY COMPUTER APPLICATIONS, 2001, : 393 - 397