Adequate stimuli of the carotid body: More than an oxygen sensor?

被引:53
|
作者
Kumar, Prem [1 ]
Bin-Jahah, Ismaeel
机构
[1] Univ Birmingham, Sch Med, Dept Physiol, Birmingham B15 2TT, W Midlands, England
[2] King Khalid Univ, Coll Med, Dept Physiol, Abha, Saudi Arabia
关键词
carotid body; hypoxia; stimulus-response; polymodal receptor; chemotransduction;
D O I
10.1016/j.resp.2007.01.007
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The past 10-20 years has seen a significant increase in the number of studies aimed at elucidating the mechanism of action of the carotid body and this has led to an increased knowledge of how this sensory organ transduces hypoxaemia into afferent chemodischarge. Whilst hypoxia is often considered as the most significant, peripheral chemostimulus, the carotid body is able to transduce many other physico-chemical stimuli, including not only arterial P-CO2 and pH but also blood potassium concentration, temperature and osmolarity as well as, potentially, blood glucose levels and all with appropriate physiological sensitivity. Although it is difficult to be definitive, these other stimuli appear to be sensed independently of the hypoxia transduction process, albeit converging at the point of type I cell membrane depolarisation or Ca2+-dependent neurosecretion. We suggest, therefore, that the carotid body might better be viewed as a polymodal receptor with its multiple adequate stimuli interacting to provide additive or greater than additive effects upon chemoafferent discharge for the purpose of cardiorespiratory homeostasis during periods of stress. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:12 / 21
页数:10
相关论文
共 50 条
  • [1] Hydrogen sulfide is an oxygen sensor in the carotid body
    Olson, Kenneth R.
    [J]. RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2011, 179 (2-3) : 103 - 110
  • [2] Cytochrome oxidase is the primary oxygen sensor in the cat carotid body
    Lahiri, S
    Chugh, DK
    Mokashi, A
    Vinogradov, S
    Osanai, S
    Wilson, DF
    [J]. OXYGEN TRANSPORT TO TISSUE XVII, 1996, 388 : 213 - 217
  • [3] IDEAL BODY WEIGHT IS MORE ACCURATE THAN TOTAL BODY WEIGHT FOR ADEQUATE LEVOTHYROXINE REPLACEMENT IN OBESE PATIENTS
    Glymph, K.
    Gosmanov, A.
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2015, 63 (02) : 462 - 462
  • [4] Quotidian dialysis: More than adequate.
    Suri, R
    Depner, TA
    Heidenheim, AP
    Leitch, R
    Lindsay, RM
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 : 20A - 21A
  • [5] POTASH - SUPPLY IS MORE THAN ADEQUATE, FOR NOW
    LYON, FD
    [J]. E&MJ-ENGINEERING AND MINING JOURNAL, 1977, 178 (03): : 126 - 127
  • [6] The carotid body in cardiovascular disease: more chicken and egg than horse and cart?
    Kumar, Prem
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 2012, 590 (17): : 4123 - 4123
  • [7] Necessity of adequate monitoring during carotid body tumors
    Baysal, Ayse
    Sasmazel, Ahmet
    Bugra, Onursal
    Zeybek, Rahmi
    [J]. ANADOLU KARDIYOLOJI DERGISI-THE ANATOLIAN JOURNAL OF CARDIOLOGY, 2010, 10 (04): : 380 - 381
  • [8] MORE THAN ADEQUATE LOGIC: BLANCHOT AVEC SADE
    Loughead, Tanya
    [J]. JOURNAL OF THE BRITISH SOCIETY FOR PHENOMENOLOGY, 2010, 41 (01) : 33 - 47
  • [9] OXYGEN CONSUMPTION OF CAROTID BODY
    FAY, FS
    PAPPENHE.JR
    [J]. FEDERATION PROCEEDINGS, 1969, 28 (02) : 338 - &
  • [10] Oxygen sensing in the carotid body
    Gonzalez, C
    Vicario, I
    Almaraz, L
    Rigual, R
    [J]. BIOLOGICAL SIGNALS, 1995, 4 (05): : 245 - 256