Microdosimetric investigation of the radiation quality of low-medium energy electrons using Geant4-DNA

被引:19
|
作者
Kyriakou, Ioanna [1 ]
Tremi, Ioanna [2 ]
Georgakilas, Alexandros G. [2 ]
Emfietzoglou, Dimitris [1 ]
机构
[1] Univ Ioannina, Med Phys Lab, Med Sch, Ioannina 45110, Greece
[2] Natl Tech Univ Athens NTUA, Sch Appl Math & Phys Sci, Phys Dept, DNA Damage Lab, Athens, Greece
关键词
Geant4-DNA; Microdosimetry; Biological effects of radiation; Quality factor; RBE; LET; RELATIVE BIOLOGICAL EFFECTIVENESS; MONTE-CARLO-SIMULATION; DOUBLE-STRAND BREAKS; CLUSTERED DNA LESIONS; TRACK-STRUCTURE; BRACHYTHERAPY SOURCES; LIQUID WATER; IONIZING-RADIATIONS; LINEAL ENERGY; TOPAS-NBIO;
D O I
10.1016/j.apradiso.2021.109654
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The increasing clinical use of low-energy photon and electron sources (below few tens of keV) has raised concerns on the adequacy of the existing approximation of an energy-independent radiobiological effectiveness. In this work, the variation of the quality factor (Q) and relative biological effectiveness (RBE) of electrons over the low-medium energy range (0.1 keV-1 MeV) is examined using several microdosimetry-based Monte Carlo methodologies with input data obtained from Geant4-DNA track-structure simulations. The sensitivity of the results to the different methodologies, Geant4-DNA physics models, and target sizes is examined. Calculations of Q and RBE are based on the ICRU Report 40 recommendations, the Kellerer-Hahn approximation, the site version of the theory of dual radiation action (TDRA), the microdosimetric kinetic model (MKM) of cell survival, and the calculated yield of DNA double strand breaks (DSB). The stochastic energy deposition spectra needed as input in the above approaches have been calculated for nanometer spherical volumes using the different electron physics models of Geant4-DNA. Results are normalized at 100 keV electrons which is here considered the reference radiation. It is shown that in the energy range similar to 50 keV-1 MeV, the calculated Q and RBE are approximately unity (to within 1-2%) irrespective of the methodology, Geant4-DNA physics model, and target size. At lower energies, Q and RBE become energy-dependent reaching a maximum value of similar to 1.5-2.5 between similar to 200 and 700 eV. The detailed variation of Q and RBE at low energies depends mostly upon the adopted methodology and target size, and less so upon the Geant4-DNA physics model. Overall, the DSB yield predicts the highest RBE values (with RBEmax approximate to 2.5) whereas the MKM the lowest RBE values (with RBEmax approximate to 1.5). The ICRU Report 40, Kellerer-Hahn, and TDRA methods are in excellent agreement (to within 1-2%) over the whole energy range predicting a Q(max) approximate to 2. In conclusion, the approximation Q = RBE = 1 was found to be valid only above similar to 50 keV whereas at lower energies both Q and RBE become strongly energy-dependent. It is envisioned that the present work will contribute towards establishing robust methodologies to determine theoretically the energy-dependence of radiation quality of individual electrons which may then be used in subsequent calculations involving practical electron and photon radiation sources.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Microdosimetric calculations of the direct DNA damage induced by low energy electrons using the Geant4-DNA Monte Carlo code
    Margis, Stefanos
    Magouni, Maria
    Kyriakou, Ioanna
    Georgakilas, Alexandros G.
    Incerti, Sebastien
    Emfietzoglou, Dimitris
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (04):
  • [2] Microdosimetric evaluation of intermediate-energy brachytherapy sources using Geant4-DNA
    Famulari, G.
    Pater, P.
    Enger, S. A.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S192 - S192
  • [3] Evaluating direct and indirect effects of low-energy electrons using Geant4-DNA
    Choi, Eunae
    Chon, Kwon Su
    Yoon, Myong Geun
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2020, 175 (11-12): : 1042 - 1051
  • [4] Systematic Microdosimetric Data for Protons Calculated with Geant4-DNA
    Vassiliev, O.
    Peterson, C.
    Cao, W.
    Grosshans, D.
    Mohan, R.
    MEDICAL PHYSICS, 2019, 46 (06) : E121 - E121
  • [5] Preliminary Investigation of Microdosimetric Track Structure Physics Models in Geant4-DNA and RITRACKS
    Douglass, Michael
    Penfold, Scott
    Bezak, Eva
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2015, 2015
  • [6] Implementation of new physics models for low energy electrons in liquid water in Geant4-DNA
    Bordage, M. C.
    Bordes, J.
    Edel, S.
    Terrissol, M.
    Franceries, X.
    Bardies, M.
    Lampe, N.
    Incerti, S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12): : 1833 - 1840
  • [7] Systematic microdosimetric data for protons of therapeutic energies calculated with Geant4-DNA
    Vassiliev, Oleg N.
    Peterson, Christine B.
    Cao, Wenhua
    Grosshans, David R.
    Mohan, Radhe
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21):
  • [8] Track structure simulation of low energy electron damage to DNA using Geant4-DNA
    Mokari, Mojtaba
    Alamatsaz, Mohammad Hassan
    Moeini, Hossein
    Babaei-Brojeny, Ali Akbar
    Taleei, Reza
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (06):
  • [9] The influence of Geant4-DNA toolkit parameters on electron microdosimetric track structure
    Wang, Yidi
    Li, Zhanpeng
    Zhang, Shuyuan
    Tang, Wei
    Li, Xiang
    Chen, Dandan
    Sun, Liang
    JOURNAL OF RADIATION RESEARCH, 2020, 61 (01) : 58 - 67
  • [10] Calculation of microdosimetric spectra for protons using Geant4-DNA and a μ-randomness sampling algorithm for the nanometric structures
    Mokari, Mojtaba
    Moeini, Hossein
    Soleimani, Marzieh
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2021, 97 (02) : 208 - 218