A comparison between 11C-methionine PET/CT and MIBI SPECT/CT for localization of parathyroid adenomas/hyperplasia

被引:40
|
作者
Hayakawa, Nobuyuki [1 ]
Nakamoto, Yuji [1 ]
Kurihara, Kensuke [1 ]
Yasoda, Akihiro [2 ]
Kanamoto, Naotetsu [2 ,4 ]
Miura, Masako [2 ,3 ]
Inagaki, Nobuya [2 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Diagnost Imaging & Nucl Med, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Diabet Endocrinol & Nutr, Kyoto 6068507, Japan
[3] Rakuwakai Otowa Hosp, Dept Endocrinol, Kyoto, Japan
[4] Osaka City Gen Hosp, Dept Endocrinol, Osaka, Japan
关键词
C-11-methionine; hyperparathyroidism; PET; computed tomography; single-photon emission computed tomography; Tc-99m-sestamibi; ACCURATE PREOPERATIVE LOCALIZATION; PRIMARY HYPERPARATHYROIDISM; TC-99M-SESTAMIBI SPECT/CT; PLANAR SCINTIGRAPHY; SESTAMIBI; ADENOMAS; HYPERPLASIA; PHASE; CT;
D O I
10.1097/MNM.0000000000000216
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveThe purpose of this study was to compare the sensitivity of single-photon emission computed tomography/computed tomography (SPECT/CT) using Tc-99m-sestamibi (MIBI) with that of PET/CT using C-11-methionine (MET) for localization of parathyroid adenomas/hyperplasia in primary hyperparathyroidism.Materials and methodsTwenty-three patients with primary hyperparathyroidism were analyzed. Fifteen patients underwent surgery, and the remaining eight did not, but these patients were clinically diagnosed as having primary hyperparathyroidism. Patients underwent both MET PET/CT and MIBI SPECT/CT scanning. The sensitivities of both modalities were evaluated on a per-patient basis, and on a per-lesion basis for parathyroid lesions detected by surgery. The size of the parathyroid adenoma/hyperplasia and serum intact parathyroid hormone levels were compared with the results of each of the two modalities.ResultsPer-patient sensitivities of MET PET/CT and MIBI SPECT/CT were 65 and 61%, respectively. Per-lesion sensitivities of MET PET/CT and MIBI SPECT/CT were 91 and 73% for histologically confirmed adenomas and 30 and 30% for hyperplastic glands, respectively. No significant differences were observed between the two modalities. The size of uptake-positive lesions was significantly larger than that of uptake-negative lesions in both modalities. Intact parathyroid hormone levels showed no significant difference between uptake-positive and uptake-negative patients in both modalities.ConclusionThe sensitivities of MET PET/CT and MIBI SPECT/CT were comparable. MET PET/CT has a complementary role in localizing parathyroid adenomas/hyperplasia when MIBI SPECT/CT is inconclusive.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 50 条
  • [1] 11C-methionine PET/CT after inconclusive 99mTc-MIBI-SPECT/CT for localisation of parathyroid adenomas in primary hyperparathyroidism
    Braeuning, U.
    Pfannenberg, C.
    Gallwitz, B.
    Teichmann, R.
    Mueller, M.
    Dittmann, H.
    Reimold, M.
    Bares, R.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2015, 54 (01): : 26 - 30
  • [2] Comparison of 99mTc-sestamibi and 11C-methionine PET/CT in the localization of parathyroid adenomas in primary hyperparathyroidism
    Martinez-Rodriguez, I.
    Martinez-Amador, N.
    de Arcocha-Torres, M.
    Quirce, R.
    Ortega-Nava, F.
    Ibanez-Bravo, S.
    Lavado-Perez, C.
    Bravo-Ferrer, Z.
    Carril, J. M.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2014, 33 (02): : 93 - 98
  • [3] Preoperative 11C-Methionine PET/CT Enables Focussed Parathyroidectomy in MIBI-SPECT Negative Parathyroid Adenoma
    Lenschow, Christina
    Gassmann, Peter
    Wenning, Christian
    Senninger, Norbert
    Colombo-Benkmann, Mario
    WORLD JOURNAL OF SURGERY, 2015, 39 (07) : 1750 - 1757
  • [4] Preoperative 11C-Methionine PET/CT Enables Focussed Parathyroidectomy in MIBI-SPECT Negative Parathyroid Adenoma
    Christina Lenschow
    Peter Gassmann
    Christian Wenning
    Norbert Senninger
    Mario Colombo-Benkmann
    World Journal of Surgery, 2015, 39 : 1750 - 1757
  • [5] Localization of parathyroid adenomas with C11-methionine PET-CT
    Weber, T.
    Luster, M.
    CHIRURG, 2014, 85 (07): : 601 - 606
  • [6] Value of [ 11 C]-Methionine PET/CT in Preoperative Localization of Parathyroid Adenomas
    Saerens, Julie
    Velkeniers, Brigitte
    Keyaerts, Marleen
    Raeymaeckers, Steven
    Vanhoeij, Marian
    Blotwijk, Susanne
    Bravenboer, Bert
    HORMONE AND METABOLIC RESEARCH, 2021, 53 (07) : 444 - 452
  • [7] Accuracy of parathyroid imaging: a comparison of planar scintigraphy, SPECT, SPECT-CT, and C-11 methionine PET for the detection of parathyroid adenomas and glandular hyperplasia
    Oeksuez, Mehmet Oezer
    Dittmann, Helmut
    Wicke, Corinna
    Muessig, Karsten
    Bares, Roland
    Pfannenberg, Christina
    Eschmann, Susanne Martina
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2011, 17 (04): : 297 - 307
  • [8] Localization of parathyroid adenomas with 11C-Methionine PET/CT and 99mTc-sestamibi in primary hyperparathyroidism.
    Martinez-Rodriguez, I.
    Portilla-Quattrociocchi, H.
    Banzo, I.
    Quirce, R.
    De Arcocha, M.
    Jimenez-Bonilla, J.
    Rubio-Vassallo, A.
    Del Castillo Matos, R.
    Carril, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S164 - S164
  • [9] Accurate Preoperative Localization of Parathyroid Adenomas With C-11 Methionine PET/CT
    Weber, Theresia
    Maier-Funk, Clemens
    Ohlhauser, Dagmar
    Hillenbrand, Andreas
    Cammerer, Gregor
    Barth, Thomas F.
    Henne-Bruns, Doris
    Boehm, Bernhard O.
    Reske, Sven N.
    Luster, Markus
    ANNALS OF SURGERY, 2013, 257 (06) : 1124 - 1128
  • [10] Detection and Characterization of Parathyroid Adenoma/Hyperplasia for Preoperative Localization: Comparison Between 11C-Methionine PET/CT and 99mTc-Sestamibi Scintigraphy
    Chun I.K.
    Cheon G.J.
    Paeng J.C.
    Kang K.W.
    Chung J.-K.
    Lee D.S.
    Nuclear Medicine and Molecular Imaging, 2013, 47 (3) : 166 - 172