Assessing glycemia in type 1 diabetic patients using a microdialysis system for continuous glucose monitoring

被引:6
|
作者
Radman, Maja
Jurisic, Dubravka
Ljutic, Dragan
Lerkovic, Romana
Kovacic, Natasa
Hozo, Izet Salih
机构
[1] Clin Hosp Split, Dept Internal Med, Gastroenterol & Hepatol Unit, Split, Croatia
[2] Clin Hosp Split, Dept Internal Med, Endocrinol Unit, Split, Croatia
[3] Clin Hosp Split, Dept Internal Med, Nephrol Unit, Split, Croatia
[4] Clin Hosp Ctr, Dept Internal Med, Endocrinol Unit, Rijeka, Croatia
[5] Univ Rijeka, Dept Anat, Fac Med, Rijeka, Croatia
[6] Diagnostics, Florence, Italy
关键词
D O I
10.5144/0256-4947.2007.166
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Continuous glucose monitoring systems can monitor moment-to-moment changes in blood glucose concentration, which cannot be detected by intermittent self-monitoring. Continuing monitoring systems may lead to improved glycemic control. We evaluated a microdialysis technique for improving glycemic control in type 1 diabetes patients treated by different means of basal insulin substitution. PATIENTS AND METHODS: Fifty-two type I diabetic patients on twice daily NPH and pre-meal aspart insulin were randomized in two groups: the continuation of NPH (n=26) (group 1) or once daily glargine (n=26) (group 2). 48-hour GlucoDay registrations were started at the beginning and after 4 months. RESULTS: At baseline, time spent in the euglycemic range (glucose between 3.9 and 8.0 mmol/L) was 37.96 +/- 6.81% for the NPH group and 35.83 +/- 6.240% for the glargine group. At endpoint, time in the euglycemic range increased in both groups (51.02 +/- 7.22% and 57.29 +/- 10.27%, P<0.001 vs. before treatment for both groups). Time spent in the hypoglycernic range (glucose <3.9 mmol/L) was 9.98 +/- 2.57% for the first group and 10.24 +/- 3.55% for the second group at baseline. At endpoint, time in the hypoglycernic range decreased in both groups (8.00 +/- 2.13% and 6.59 +/- 2.04%, P<0.001 vs. before treatment for both groups). CONCLUSION: The analysis of the GlucoDay data gave us information about glycemia other than HbA1c and self-monitoring of blood glucose, such us a peakless activity profile and the lower percentage of time spent in the hypoglycernic range in the glargine-treated group.
引用
收藏
页码:166 / 170
页数:5
相关论文
共 50 条
  • [1] Assessment of glycemia using continuous glucose monitoring system in adult male diabetic patients
    Ghalib, L
    Pungan, R
    Krueger, N
    Perlmuter, L
    Singh, S
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONGRESS OF ENDOCRINOLOGY, 2004, : 663 - 667
  • [2] A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 1)
    Poscia, A
    Mascini, M
    Moscone, D
    Luzzana, M
    Caramenti, G
    Cremonesi, P
    Valgimigli, F
    Bongiovanni, C
    Varalli, M
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (07): : 891 - 898
  • [3] Predicting Glycemia in Diabetic Patients By Evolutionary Computation and Continuous Glucose Monitoring
    Manuel Colmenar, J.
    Winkler, Stephan M.
    Kronberger, Gabriel
    Maqueda, Esther
    Botella, Marta
    Ignacio Hidalgo, J.
    PROCEEDINGS OF THE 2016 GENETIC AND EVOLUTIONARY COMPUTATION CONFERENCE (GECCO'16 COMPANION), 2016, : 1393 - 1400
  • [4] Microdialysis system for continuous glucose monitoring
    Steinkuhl, R
    Sundermeier, C
    Hinkers, H
    Dumschat, C
    Cammann, K
    Knoll, M
    SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) : 19 - 24
  • [5] Comparison of a needle-type and a microdialysis continuous glucose monitor in type 1 diabetic patients
    Wentholt, IM
    Vollebregt, MA
    Hart, AA
    Hoekstra, JB
    DeVries, JH
    DIABETES CARE, 2005, 28 (12) : 2871 - 2876
  • [6] The rare side effect during Microdialysis continuous subcutaneous glucose monitoring in type 1 diabetic patient
    Radman, Maja
    Erzen, Dubravka Jurisic
    Ljutic, Dragan
    Soldo, Dragica
    Sincic-Mijandrusic, Brankica
    Jerkovic, Romana
    ENDOCRINOLOGIST, 2007, 17 (05): : 252 - 254
  • [7] Glucose monitoring in the adipose tissue of type 1 diabetic patients using open-flow microperfusion and microdialysis
    Schaupp, L
    Brunner, GA
    Schaller, H
    Bodenlenz, M
    Wutte, A
    Wach, P
    Pieber, TR
    DIABETOLOGIA, 2001, 44 : A46 - A46
  • [8] A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 2)
    Varalli, M
    Marelli, G
    Maran, A
    Bistoni, S
    Luzzana, M
    Cremonesi, P
    Caramenti, G
    Valgimigli, F
    Poscia, A
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (07): : 899 - 905
  • [9] CONTINUOUS BLOOD GLUCOSE MONITORING SYSTEM USING INTRAVENOUS MICRODIALYSIS AND GLUCOSE SENSING
    Schaller-Ammann, R.
    Greiner, H.
    Huber, A.
    O'Connell, M.
    Krejci, J.
    Porro, G.
    Korsatko, S.
    Gurban, J.
    Deller, S.
    Brunner, M.
    Berghofer, A.
    Priedl, J.
    Zijlstra, E.
    Heise, T.
    Pieber, T. R.
    Schaupp, L.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A72 - A72
  • [10] Continuous glucose monitoring in type 1 diabetic patients with continuous subcutaneous insulin infusion
    Alves, Marta
    Neves, Celestino
    Varela, Ana
    Arteiro, Cristina
    Pereira, Luis M.
    Carvaiho, Davide
    Medina, Jose L.
    DIABETES, 2008, 57 : A547 - A547