Wide Area Islanding Detection using Phasor Measurement Unit

被引:0
|
作者
Kumar, Dhruba [1 ]
Bhowmik, Partha Sarathee [1 ]
机构
[1] Natl Inst Technol Durgapur, Dept Elect Engn, Durgapur, W Bengal, India
关键词
Islanding detection; Phasor Measurement Unit (PMU); Phasor Data Concentrator (PDC); Smart grid; Micro grid; SYSTEM;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Islanding is a special type of open circuit fault where the distributed resource continues to feed local loads during loss of mains situation. This paper develops a technique to detect islanding in a six bus power system. The input to the technique is dependent on synchrophasor measurement. The decision made in the technique is based on IEC62116 standards and predefined threshold and of current phasors. Synchrophasor based islanding detection can be considered as communication based islanding detection where measurements from both islanded region and grid connected region are utilized for islanding detection. PMU based islanding detection is highly recommended to predetermine cascading line outage and to check voltage profile of islanded region.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 50 条
  • [1] Phasor Measurement Unit Placement for Wide Area Instability Detection and Prediction
    Lopez, Javier A.
    Lu, Chan-nan
    [J]. 2017 IEEE 3RD INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE AND ECCE ASIA (IFEEC 2017-ECCE ASIA), 2017, : 1708 - 1713
  • [2] Wide Area Measurement and Control using Phasor Measurement unit in Smart Grid
    Sutar, Chandarani
    Verma, K. S.
    Pandey, A. S.
    Singh, S. P.
    [J]. 2012 2ND INTERNATIONAL CONFERENCE ON POWER, CONTROL AND EMBEDDED SYSTEMS (ICPCES 2012), 2012,
  • [3] ISLANDING DETECTION WITH PHASOR MEASUREMENT UNITS
    Cardenas, Jorge
    Mikhael, George
    Kaminski, Jacek
    Voloh, Ilia
    [J]. 2014 67TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2014, : 229 - 241
  • [4] Performance Simulation of Phasor Measurement Unit for Wide Area Measurement System
    Ghosh, Debomita
    Kumar, Chandan
    Ghose, T.
    Mohanta, D. K.
    [J]. 2014 INTERNATIONAL CONFERENCE ON CONTROL, INSTRUMENTATION, ENERGY & COMMUNICATION (CIEC), 2014, : 242 - 245
  • [5] Islanding Based Optimal Placement of Phasor Measurement Unit using MILP
    Singh, Satyendra Pratap
    Singh, S. P.
    [J]. 2016 IEEE 7TH POWER INDIA INTERNATIONAL CONFERENCE (PIICON), 2016,
  • [6] Review of the Techniques of the Data Analytics and Islanding Detection of Distribution Systems Using Phasor Measurement Unit Data
    Arefin, Ahmed Amirul
    Baba, Maveeya
    Singh, Narinderjit Singh Sawaran
    Nor, Nursyarizal Bin Mohd
    Sheikh, Muhammad Aman
    Kannan, Ramani
    Abro, Ghulam E. Mustafa
    Mathur, Nirbhay
    [J]. ELECTRONICS, 2022, 11 (18)
  • [7] Simulation of Wide Area Measurement System with Optimal Phasor Measurement Unit Location
    Das, Soumik
    Ghosh, Debomita
    Ghose, T.
    Mohanta, D. K.
    [J]. 2014 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND INTEGRATED NETWORKS (SPIN), 2014, : 226 - 230
  • [8] Simulation and Implementation of Phasor Measurement Unit for Wide Area Monitoring System
    Devaraj, D.
    Paramathma, M. Krishna
    Rajalakshmi, I
    [J]. 2017 IEEE INTERNATIONAL CONFERENCE ON INTELLIGENT TECHNIQUES IN CONTROL, OPTIMIZATION AND SIGNAL PROCESSING (INCOS), 2017,
  • [9] Phasor Measurement Unit (PMU) Based Wide Area Protection System
    Urooj, Shabana
    Sood, Vani
    [J]. 2015 2ND INTERNATIONAL CONFERENCE ON COMPUTING FOR SUSTAINABLE GLOBAL DEVELOPMENT (INDIACOM), 2015, : 597 - 599
  • [10] Monitoring Fault Diagnosis Based on Phasor Measurement Unit at Wide Area Systems
    Zakri, Azriyenni Azhari
    Mustafa, Mohd Wazir
    Syaibi, Herman
    Sofimieari, Ibim
    [J]. 2019 IEEE CONFERENCE ON ENERGY CONVERSION (CENCON), 2019, : 245 - 249