Rapid high resolution imaging with a dual-channel scanning technique

被引:40
|
作者
de Castro, Alberto [1 ]
Huang, Gang [1 ]
Sawides, Lucie [1 ]
Luo, Ting [1 ]
Burns, Stephen A. [1 ]
机构
[1] Indiana Univ, Sch Optometry, 800 E Atwater, Bloomington, IN 47405 USA
关键词
RETINAL BLOOD-FLOW; LASER OPHTHALMOSCOPE; BLUE FIELD; ENTOPTIC PHENOMENON; VELOCITY; TOMOGRAPHY; MICROCIRCULATION; VISUALIZATION; CAPILLARIES; LEUKOCYTES;
D O I
10.1364/OL.41.001881
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A spatial shift between channels in a dual-beam raster-scan imaging system introduces a temporal separation between images from the two channels that can be much shorter than the frame rate of the system. The technique is demonstrated by measuring the velocity of erythrocytes in the retinal capillaries. We used an adaptive optics scanning laser ophthalmoscope and introduced a temporal separation between imaging channels of 4.7 ms. We imaged three subjects and measured changing capillary blood flow velocity at the pulse rate. Since the time shift between channels is easily and continuously adjustable, this method can be used to measure rapidly changing events in any raster scan system with little added complexity. (C) 2016 Optical Society of America
引用
收藏
页码:1881 / 1884
页数:4
相关论文
共 50 条
  • [1] Dual-channel snapshot imaging spectrometer with wide spectrum and high resolution
    Zhao, Shijia
    Zeng, Chenxin
    Ji, Yiqun
    Tan, Fenli
    Wang, Chinhua
    [J]. APPLIED OPTICS, 2023, 62 (21) : 5830 - 5838
  • [2] Moving Target Imaging Using Dual-Channel High Resolution 35 GHz SAR Radar
    Drozdowicz, Jedrzej
    [J]. 2016 17TH INTERNATIONAL RADAR SYMPOSIUM (IRS), 2016,
  • [3] Vibration Target Imaging Based on the DPCA Technique in Dual-channel SAR
    Chen, Ying-bin
    Deng, Bin
    Wang, Hong-qiang
    Lu, Guang-hui
    [J]. 2ND INTERNATIONAL CONFERENCE ON COMMUNICATIONS, INFORMATION MANAGEMENT AND NETWORK SECURITY (CIMNS 2017), 2017, : 208 - 213
  • [4] DIAGNOSTIC EFFICACY OF DUAL-CHANNEL PANCREAS SCANNING
    KAPLAN, E
    FINK, S
    BENPORAT.M
    CLAYTON, GD
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1968, 9 (06): : 330 - &
  • [5] CURRENT STATUS OF DUAL-CHANNEL PANCREAS SCANNING
    FINK, S
    BENPORAT.M
    JACOBSON, B
    CLAYTON, GD
    KAPLAN, E
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1969, 10 (02): : 78 - &
  • [6] DIAGNOSIS OF CARCINOMA OF PANCREAS BY DUAL-CHANNEL SCANNING
    FINK, S
    JACOBSON, B
    BENPORAT.M
    CLAYTON, GD
    KAPLAN, E
    [J]. GASTROENTEROLOGY, 1967, 52 (06) : 1083 - &
  • [7] Dual-channel polarization imaging spectrometer
    Mu, Tingkui
    Zhang, Chunmin
    [J]. NEXT-GENERATION SPECTROSCOPIC TECHNOLOGIES IV, 2011, 8032
  • [8] Dual-channel inline coherent imaging
    Altal, Faleh
    Allen, Troy R.
    Nestor, Stephen G. L.
    Fleming, Tristan G.
    Fraser, James M.
    [J]. APPLIED OPTICS, 2019, 58 (07) : 1614 - 1620
  • [9] A dual-channel imaging polarimetry system
    Wang, Xue
    Ren, Deqing
    Dou, Jiangpei
    Zhu, Yongtian
    Zhang, Xi
    [J]. 2011 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SYSTEMS AND MODERN OPTOELECTRONIC INSTRUMENTS, 2011, 8197
  • [10] High Resolution Dual-Channel SAR-System for Airborne Applications
    Caris, M.
    Brehm, T.
    Palm, S.
    Sieger, S.
    Kloeppel, F.
    Sommer, R.
    Janssen, D.
    Port, V.
    Stanko, S.
    [J]. 2017 18TH INTERNATIONAL RADAR SYMPOSIUM (IRS), 2017,