A novel simplified configuration for an ideal heat-integrated distillation column (ideal HIDiC)

被引:56
|
作者
Chen, Haisheng [1 ]
Huang, Kejin [1 ]
Wang, Shaofeng [1 ]
机构
[1] Beijing Univ Chem Technol, Coll Informat Sci & Technol, Beijing 100029, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
Distillation; Heat integration; Thermodynamic efficiency; Process synthesis; Process design; CONCEPTUAL DESIGN;
D O I
10.1016/j.seppur.2010.04.006
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Although the ideal heat-integrated distillation column (ideal HIDiC) is much more thermodynamically efficient than its conventional analogues, its applications in the chemical and petrochemical process industries have been restrained due to the great difficulties and complexities in the design and implementation of internal heat integration between the rectifying section and the stripping section. For the avoidance of these difficulties and complexities, a novel simplified configuration for the ideal HIDiC, termed the SIHIDiC, is proposed and studied in this paper. Only three internal heat exchangers are used to approximate the internal heat integration, and their locations and sizes are key decision variables for process synthesis and design and should be considered to enhance thermodynamic efficiency in process development. A simple stepwise procedure is thus derived for process synthesis and design, and the SIHIDiC is then evaluated through intensive comparison with conventional distillation columns and the ideal HIDiC in terms of the separations of ethylene/ethane and benzene/toluene binary mixtures. The results obtained indicate that the SIHIDiC could be an excellent candidate to approximate the ideal HIDiC with reduced capital investment and somewhat similar (if not smaller) operating cost. The SIHIDiC offers essentially a much simpler way than the current available methods to design and implement the concept of the ideal HIDiC into separation processes. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:230 / 242
页数:13
相关论文
共 50 条
  • [1] Simplified design and control of an ideal heat-integrated distillation column (ideal HIDiC)
    Wu, Guosong
    Huang, Kejin
    Chen, Haisheng
    Wang, Shaofeng
    Wei, Ningning
    Wang, San-Jang
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2012, 7 (06) : 912 - 927
  • [2] Temperature control of an ideal heat-integrated distillation column (HIDiC)
    Huang, Kejin
    Wang, San-Jang
    Iwakabe, Koichi
    Shan, Lan
    Zhu, Qunxiong
    CHEMICAL ENGINEERING SCIENCE, 2007, 62 (22) : 6486 - 6491
  • [3] Characteristics of energy savings in an ideal heat-integrated distillation column (HIDiC)
    Nakaiwa, M
    Huang, KJ
    Owa, M
    Akiya, T
    Nakane, T
    Sato, M
    Takamatsu, T
    IECEC-97 - PROCEEDINGS OF THE THIRTY-SECOND INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE, VOLS 1-4: VOL.1: AEROSPACE POWER SYSTEMS AND TECHNOL; VOL 2: ELECTROCHEMICAL TECHNOL, CONVERSION TECHNOL, THERMAL MANAGEMENT; VOLS 3: ENERGY SYSTEMS, RENEWABLE ENERGY RESOURCES, ENVIRONMENTAL IMPACT, POLICY IMPACTS ON ENERGY; VOL 4: POST DEADLINE PAPERS, INDEX, 1997, : 1587 - 1591
  • [4] The influences of pressure distribution on an ideal heat-integrated distillation column (HIDiC)
    Huang, Kejin
    Matsuda, Keigo
    Takamatsu, Takeichiro
    Nakaiwa, Masaru
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2006, 39 (06) : 652 - 660
  • [5] A new configuration of ideal heat integrated distillation columns (HIDiC)
    Nakaiwa, M
    Huang, K
    Naito, K
    Endo, A
    Owa, M
    Akiya, T
    Nakane, T
    Takamatsu, T
    COMPUTERS & CHEMICAL ENGINEERING, 2000, 24 (2-7) : 239 - 245
  • [6] Design and control of an ideal heat-integrated distillation column (ideal HIDiC) system separating a close-boiling ternary mixture
    Huang, Kejin
    Shan, Lan
    Zhu, Qunxiong
    Qian, Jixin
    ENERGY, 2007, 32 (11) : 2148 - 2156
  • [7] Determining appropriate configuration of ideal heat integrated distillation columns (HIDiC)
    Huang, KJ
    Nakaiwa, M
    Owa, M
    Akiya, T
    Aso, K
    Takamatsu, T
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1997, 30 (03) : 575 - 579
  • [8] Minimum and total reflux in ideal heat integrated distillation column (HIDiC)
    Takamatsu, T
    Nakaiwa, M
    KAGAKU KOGAKU RONBUNSHU, 1996, 22 (06) : 1461 - 1464
  • [9] Minimum and Total Reflux in Ideal Heat Integrated Distillation Column (HIDiC)
    Takamatsu, T.
    Nakaiwa, M.
    Kagaku Kogaku Ronbunshu, 22 (06):
  • [10] Minimum and total reflux in ideal heat integrated distillation column (HIDiC)
    Research Institute of Industrial Technology, Kansai University, Suita
    564, Japan
    不详
    305, Japan
    Kagaku Kogaku Ronbunshu, 6 (1461-1464):