Breakdown Characteristics of Transformer Oil in a Uniform Field under Oscillating Impulse Voltage

被引:9
|
作者
Li, Junhao [1 ]
Zhang, Liang [1 ]
Jin, Yuhui [1 ]
Yao, Xiu [2 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian, Peoples R China
[2] SUNY Buffalo, Dept Elect Engn, Buffalo, NY USA
关键词
Breakdown characteristics; transformer oil; oscillating impulse voltage; uniform filed; INSULATION CHARACTERISTICS; IMMERSED TRANSFORMERS; MINERAL-OIL; WAVE-FORMS; STREAMERS; STANDARD;
D O I
10.1109/TDEI.2017.005996
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The field impulse voltage test plays the most important role to ensure the safe of the power transformer. It is hard to carry out the standard impulse voltage test for the power equipment because the generator is very huge. The oscillating impulse voltage waveform has high efficiency and be recommended by IEC 60060-3 as the field test waveform. Transformer oil is the main insulation part of power transformer insulation system. The insulation characteristics of transformer oil under different type impulse waveform have great influence to the design, operation and test amplitude for the power transformer. This paper focuses on the breakdown characteristics of transformer oil in a uniform field under oscillating impulse voltage (OIV). Three type oscillating impulse voltage waveforms with oscillating frequency of 14, 117 and 373 kHz were adopted as the test waveforms. The standard lightning impulse (SLI) voltage was also adopted as the reference waveform. The experiment results show the breakdown waveforms have large oscillation under OIV but little oscillation under SLI for the influence of circuit inductor. The minimum breakdown voltage increase with the increase of oscillating frequency and the 117 kHz impulse waveform has the similar breakdown voltage with SLI waveform. The voltage-time distributions were obtained through lab test and the results shown that the OIV have the longer time lag than SLI for the influence of the oscillation of waveform. The experimental results were explained through streamer mechanism. The study provides the foundation for the field impulse test using oscillating impulse waveform.
引用
收藏
页码:984 / 990
页数:7
相关论文
共 50 条
  • [1] Pre-Breakdown Characteristics in Transformer Oil under Bipolar Oscillating Impulse Voltage
    Ding, Can
    Tu, Tiancheng
    Fang, Chunhua
    Yuan, Fating
    Li, Chengxi
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 4493 - 4496
  • [2] Breakdown Characteristics of Transformer Oil Under Negative Oscillating Switching Impulse in Non-uniform Electric Field
    Sun, Wenxing
    Yang, Xian
    Xiao, Xiang
    Cai, Linglong
    Ma, Zhiqin
    Sun, Shanyuan
    Li, Junhao
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (07): : 2545 - 2552
  • [3] Breakdown Characteristics of Transformer Oil Under Bipolar Oscillating Impulse
    Ni H.
    Zhang Q.
    Zhao Y.
    Guo N.
    Fan X.
    Liu X.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (12): : 3827 - 3835
  • [4] Breakdown Characteristics of Transformer Oil with Cellulose Particles in a Non-uniform Field under Lightning Impulse Voltage
    Guo, Ruochen
    Wang, Zhen
    He, Cong
    Zhang, Xuanrui
    Meng, Xuan
    Li, Junhao
    Han, Xutao
    Yao, Xiu
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (05) : 1627 - 1635
  • [5] Impulse Breakdown Characteristics of Transformer Oil with Cellulose Particles in Quasi-Uniform Field
    Guo, Ruochen
    Wang, Zhen
    He, Cong
    Meng, Xuan
    Li, Junhao
    Han, Xutao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (01) : 107 - 115
  • [6] Breakdown Characteristics of a Transformer Oil in Moderately-Uniform Fields under Lightning Impulse
    Yu, Haichuan
    Liu, Qiang
    Wang, Zhongdong
    Wilkinson, Mark
    Krause, Christoph
    Gyore, Attila
    Hilker, Andree
    2022 IEEE 21ST INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2022,
  • [7] Breakdown Characteristics of Transformer Oil Insulation under Impulse Voltage with Different Waveform Parameters
    Zhao Tao
    Liu Yunpeng
    Lv Fangcheng
    Cheng Xiangrui
    Wang Zibo
    Wang Fochi
    Xie Qing
    2017 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2017, : 368 - 371
  • [8] Effect of oscillation frequency on the breakdown characteristics of transformer oil in a highly nonuniform field under lightning impulse voltage
    Guo, Ruochen
    Hou, Zhiqiang
    Wang, Zhen
    He, Cong
    Zhang, Xuanrui
    Li, Junhao
    Jin, Yuhui
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (03) : 812 - 819
  • [9] Investigation on Transformer Oil Impedance during Breakdown under Impulse Voltage
    Abdi, S.
    Boubakeur, A.
    Haddad, A.
    Harid, N.
    2014 ELECTRICAL INSULATION CONFERENCE (EIC), 2014, : 5 - 9
  • [10] Breakdown Characteristics of Transformer Turn-insulation Under Double-exponential and Oscillating Switching Impulse Voltage
    Cao D.
    Guo R.
    Cai L.
    Jin Y.
    Hu W.
    Li J.
    Gaodianya Jishu/High Voltage Engineering, 2022, 48 (06): : 2265 - 2275