Prevention of parastomal hernia after abdominoperineal excision with a prophylactic three-dimensional funnel mesh

被引:17
|
作者
Lopez-Borao, J. [1 ]
Madrazo-Gonzalez, Z. [1 ]
Kreisler, E. [1 ]
Biondo, S. [1 ]
机构
[1] Univ Barcelona, Bellvitge Univ Hosp, IDIBELL, Dept Gen & Digest Surg,Colorectal Unit, Feixa Llarga S-N, Barcelona 08907, Spain
关键词
Abdominoperineal excision; permanent end-colostomy; parastomal hernia; keyhole technique; END-COLOSTOMY; METAANALYSIS; RISK; CLASSIFICATION; COMPLICATIONS; REPAIR;
D O I
10.1111/codi.14738
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Aim A prophylactic three-dimensional (3D) funnel mesh using the keyhole technique (intraperitoneal onlay mesh position) in abdominoperineal excision (APR) may significantly decrease the parastomal hernia (PSH) index without increasing morbidity. The aim of this retrospective observational study was to analyse the incidence of PSH and postoperative complications in patients who underwent permanent colostomy with the use of a prophylactic 3D preformed mesh compared with patients without a mesh. Method Patients who underwent an end-colostomy after APR for primary or recurrent rectal cancer in a colorectal surgery unit were divided into two groups: group 1 without a prophylactic mesh and group 2 with a prophylactic synthetic mesh. The main end-point was to analyse the incidence of PSH after a median follow-up of 2.8 years. Results One hundred and ten patients (64 in group 1 and 46 in group 2, without significant clinical differences) underwent a permanent colostomy after APR. In group 1 70.3% developed a PSH, compared with 13% in group 2 (P < 0.001). Age (especially for patients >= 75 years) represented a significant risk factor for PSH. There were no differences in postoperative complications between the groups. Conclusion A prophylactic parastomal 3D mesh using the keyhole technique may reduce the incidence of PSH after permanent colostomy without an increase in postoperative complications.
引用
收藏
页码:1326 / 1334
页数:9
相关论文
共 50 条
  • [1] EVALUATION OF A NOVEL THREE-DIMENSIONAL FUNNEL MESH FOR PARASTOMAL HERNIA REPAIR AFTER ILEAL CONDUIT DIVERSION
    Tully, Karl
    Roghmann, Florian
    Pastor, Jobst
    Palisaar, Rein Jueri
    Noldus, Joachim
    von Bodman, Christian
    JOURNAL OF UROLOGY, 2017, 197 (04): : E711 - E711
  • [2] Permanent end-colostomy parastomal hernia prevention using a novel three-dimensional mesh
    Camillo Leonardo Bertoglio
    Marianna Maspero
    Lorenzo Morini
    Andrea Zironda
    Bruno Domenico Alampi
    Michele Mazzola
    Carmelo Magistro
    Pietro Carnevali
    Giovanni Ferrari
    Hernia, 2021, 25 : 655 - 663
  • [3] Permanent end-colostomy parastomal hernia prevention using a novel three-dimensional mesh
    Bertoglio, Camillo Leonardo
    Maspero, Marianna
    Morini, Lorenzo
    Zironda, Andrea
    Alampi, Bruno Domenico
    Mazzola, Michele
    Magistro, Carmelo
    Carnevali, Pietro
    Ferrari, Giovanni
    HERNIA, 2021, 25 (03) : 655 - 663
  • [4] Prophylactic funnel mesh to prevent parastomal hernia in permanent end colostomy: A retrospective cohort study
    Ammann, Yanic
    Widmann, Bernhard
    Sparn, Moritz
    Warschkow, Rene
    Weitzendorfer, Michael
    Brunner, Walter
    COLORECTAL DISEASE, 2021, 23 (10) : 2627 - 2636
  • [5] Parastomal hernia prevention with an intraperitoneal prophylactic 3D-funnel mesh: review of the technique and middle-term results
    Badia-Closa, Jesus
    Comas-Isus, Jaume
    Centeno-Alvarez, Ana
    Arrayas-Valverde, Angela
    Subirana-Magdaleno, Helena
    Sobrerroca-Porras, Laura
    Mullerat-Prat, Jose Maria
    Castellvi-Valls, Jordi
    HERNIA, 2024, 28 (04) : 1129 - 1135
  • [6] Laparoscopic-assisted extralevator abdominoperineal excision using a parastomal prophylactic mesh and a biological mesh for pelvic floor reconstruction
    R. Ghinea
    I. White
    B. Benjamin
    D. Kidron
    B. Shpitz
    S. Avital
    Techniques in Coloproctology, 2015, 19 : 317 - 318
  • [7] Laparoscopic-assisted extralevator abdominoperineal excision using a parastomal prophylactic mesh and a biological mesh for pelvic floor reconstruction
    Ghinea, R.
    White, I.
    Benjamin, B.
    Kidron, D.
    Shpitz, B.
    Avital, S.
    TECHNIQUES IN COLOPROCTOLOGY, 2015, 19 (05) : 317 - 318
  • [8] Mesh Prevention of Parastomal Hernia After Permanent End Colostomy
    Hauters, P.
    Cardin, J. L.
    Lepere, M.
    Valverde, A.
    Cossa, J. P.
    Auvray, S.
    Landenne, J.
    Framery, D.
    E-MEMOIRES DE L ACADEMIE NATIONALE DE CHIRURGIE, 2015, 14 (04): : 56 - 60
  • [9] Laparoscopic prevention of parastomal hernia with mesh in definite stomas after abdominoperineal resection: Texas Endosurgery Institute (TEI) experience
    Rodriguez, Ricardo J.
    Franklin, Morris E., Jr.
    Hernandez, Miguel A.
    Rangel, Hugo
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2014, 219 (04) : E70 - E70
  • [10] LAPAROSCOPIC-ASSISTED EXTRALEVATOR ABDOMINOPERINEAL EXCISION USING A PARASTOMAL PROPHYLACTIC MESH AND A BIOLOGICAL MESH FOR PELVIC FLOOR RECONSTRUCTION.
    Avital, S.
    Banjamin, B.
    Ghinea, R.
    White, I.
    Kidron, D.
    Shpitz, B.
    DISEASES OF THE COLON & RECTUM, 2015, 58 (05) : E382 - E382