A simple technique for the placement of Schanz screws into bone using minimal radiologic control

被引:0
|
作者
Lerner, A. [2 ,3 ]
Akinyoola, A. L. [1 ]
Soudry, M. [2 ,3 ]
机构
[1] Obafemi Awolowo Univ, Dept Traumat & Orthopaed Surg, Ife, Nigeria
[2] Technion Israel Inst Technol, Haifa, Israel
[3] Rambam Med Ctr, Dept Orthopaed Surg A, Haifa, Israel
关键词
FRACTURES;
D O I
10.1258/td.2009.090161
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The insertion of Schanz screws into the bone during external-fixation procedures in trauma and elective orthopaedic surgery is usually done under roentgenologic control. In order to minimize irradiation exposure for the patients, as well as surgeons, we describe a simple method of Schanz screw placement.The roentgenologic control of the position of the half-pins is only necessary at the beginning and the end of the procedure.This technique is simple, shortens the operating time and reduces the amount of radiation exposure to both the patient and surgeon. It is a valuable technique in many resource-poor environments who do not have the facilities for an image intensifier fluoroscopy or C-arm as well as in austere situations such as during military operations.
引用
收藏
页码:34 / 35
页数:2
相关论文
共 50 条
  • [1] A simple technique to verify the correct placement of locking screws through intramedullary nails
    Talbot, N. J.
    Kamath, S.
    Sharpe, I. T.
    Eyres, K. S.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2007, 89 (07) : 725 - 726
  • [2] Comparison of Cortical Bone Trajectory Screw Placement Using the Midline Lumbar Fusion Technique to Traditional Pedicle Screws: A Case-Control Study
    Hoffman, Haydn
    Verhave, Brendon
    Jalal, Muhammad S.
    Beutler, Timothy
    Galgano, Michael A.
    Chin, Lawrence S.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2019, 13 (01): : 33 - 38
  • [3] Technique Tip: A Simple Method for Ankle Arthrodesis Using Solid Screws
    Gentchos, Christopher E.
    Bohay, Donald R.
    Anderson, John G.
    FOOT & ANKLE INTERNATIONAL, 2009, 30 (04) : 380 - 383
  • [4] Flapless approach for removal of bone graft fixing screws and placement of dental implants using computerized navigation: A technique and case report
    Casap, N
    Kreiner, B
    Wexler, A
    Kohavi, D
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2006, 21 (02) : 314 - 319
  • [5] A simple technique for the capture of broken intramedullary locking screws using laparoscopic forceps
    De Pedro, Jose A.
    Blanco, Juan F.
    Ellis, Scott
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 61 (05): : 1283 - 1284
  • [6] SIMPLE TECHNIQUE FOR MAXILLOMANDIBULAR FIXATION USING PATIENT'S DENTURE AND ANCHORAGE SCREWS
    Jang, Yong-Wook
    Kim, Seong-Gon
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (01) : 236 - 237
  • [7] A simple technique to control placement of Dumon stent in subglottic tracheal stenosis†
    Fiorelli, Alfonso
    Mazzone, Salvatore
    Di Crescenzo, Vincenzo Giuseppe
    Costa, Giuseppe
    Del Prete, Assunta
    Vicidomini, Giovanni
    Mazzone, Adriano
    Santini, Mario
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 18 (03) : 390 - 392
  • [8] Placement of C1 Pedicle Screws Using Minimal Exposure: Radiographic, Clinical, and Literature Validation
    Menger, Richard P.
    Storey, Christopher M.
    Nixon, Menarvia K. C.
    Haydel, Justin
    Nanda, Anil
    Sin, Anthony
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2015, 9
  • [9] Minimal Control Placement of Turing's Model Using Symmetries
    Cao, Yuexin
    Li, Yibei
    Liu, Zhixin
    Zheng, Lirong
    Hu, Xiaoming
    2023 62ND IEEE CONFERENCE ON DECISION AND CONTROL, CDC, 2023, : 1456 - 1461
  • [10] A Simple and Minimal Invasive Method in Reduction of Depressed Nasal Bone Fracture by Using a Foley Catheter Ballooning Technique
    Xue, Ke
    Liu, Kai
    Qi, Lin
    JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (06) : E617 - E619