3D Fast Spin Echo With Out-of-Slab Cancellation: A Technique for High-Resolution Structural Imaging of Trabecular Bone at 7 Tesla

被引:22
|
作者
Magland, Jeremy F. [1 ]
Rajapakse, Chamith S. [1 ]
Wright, Alexander C. [1 ]
Acciavatti, Raymond [1 ]
Wehrli, Felix W. [1 ]
机构
[1] Univ Penn, Med Ctr, Dept Radiol, Lab Struct NMR Imaging, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
fast spin echo; FSE; RARE; trabecular bone; out-of-slab cancellation; HIGH-FIELD MRI; FLIP-ANGLE; FSE SEQUENCES; RARE; FLASE; FAT;
D O I
10.1002/mrm.22213
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spin-echo-based pulse sequences are desirable for the application of high-resolution imaging of trabecular bone but tend to involve high-power deposition. Increased availability of ultrahigh field scanners has opened new possibilities for imaging with increased signal-to-noise ratio (SNR) efficiency, but many pulse sequences that are standard at 1.5 and 3 T exceed specific absorption rate limits at 7 T. A modified, reduced specific absorption rate, three-dimensional, fast spin-echo pulse sequence optimized specifically for in vivo trabecular bone imaging at 7 T is introduced. The sequence involves a slab-selective excitation pulse, low-power nonselective refocusing pulses, and phase cycling to cancel undesired out-of-slab signal. In vivo images of the distal tibia were acquired using the technique at 1.5, 3, and 7 T field strengths, and SNR was found to increase at least linearly using receive coils of identical geometry. Signal dependence on the choice of refocusing flip angles in the echo train was analyzed experimentally and theoretically by combining the signal from hundreds of coherence pathways, and it is shown that a significant specific absorption rate reduction can be achieved with negligible SNR loss. Magn Reson Med 63:719-727, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:719 / 727
页数:9
相关论文
共 50 条
  • [1] High-resolution and fast 3D ultrasonic imaging technique
    Benenson, ZM
    Elizarov, AB
    Yakovleva, TV
    O'Brien, WD
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 1561 - 1564
  • [2] High-resolution cardiac imaging using an interleaved 3D double slab technique
    Forster, J
    Sieverding, L
    Breuer, J
    Schick, F
    Dammann, F
    Apitz, J
    Lutz, O
    MAGNETIC RESONANCE IMAGING, 1998, 16 (10) : 1155 - 1162
  • [3] High-resolution magnetic resonance imaging of trabecular bone in the wrist at 3 tesla: Initial results
    Ludescher, B
    Martirosian, P
    Lenk, S
    Machann, J
    Dammann, F
    Schick, F
    Claussen, C
    Schlemmer, H
    ACTA RADIOLOGICA, 2005, 46 (03) : 306 - 309
  • [4] High resolution imaging of the intracranial vessel wall at 3 and 7 T using 3D fast spin echo MRI
    Zhu, Chengcheng
    Haraldsson, Henrik
    Tian, Bing
    Meisel, Karl
    Ko, Nerissa
    Lawton, Michael
    Grinstead, John
    Ahn, Sinyeob
    Laub, Gerhard
    Hess, Christopher
    Saloner, David
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2016, 29 (03) : 559 - 570
  • [5] High resolution imaging of the intracranial vessel wall at 3 and 7 T using 3D fast spin echo MRI
    Chengcheng Zhu
    Henrik Haraldsson
    Bing Tian
    Karl Meisel
    Nerissa Ko
    Michael Lawton
    John Grinstead
    Sinyeob Ahn
    Gerhard Laub
    Christopher Hess
    David Saloner
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2016, 29 : 559 - 570
  • [6] Intracranial black-blood MR angiography with high-resolution 3D fast spin echo
    Alexander, AL
    Buswell, HR
    Sun, Y
    Chapman, BE
    Tsuruda, TS
    Parker, DL
    MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (02) : 298 - 310
  • [7] On the Significance of Motion Degradation in High-resolution 3D μMRI of Trabecular Bone
    Bhagat, Yusuf A.
    Rajapakse, Chamith S.
    Magland, Jeremy F.
    Wald, Michael J.
    Song, Hee Kwon
    Leonard, Mary B.
    Wehrli, Felix W.
    ACADEMIC RADIOLOGY, 2011, 18 (10) : 1205 - 1216
  • [8] Comparison of three-dimensional fast spin echo and gradient echo sequences for high-resolution temporal bone imaging
    Schmalbrock, P
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (06) : 814 - 825
  • [9] Fast High-Resolution 3D Radar Imaging Based on 3D FISTA
    Ren, Jiaying
    Lu, Xinfei
    Guan, Jian
    Yin, Zhiping
    Ehen, Weidong
    2017 IEEE RADAR CONFERENCE (RADARCONF), 2017, : 815 - 818
  • [10] High-Resolution Fourier-Encoded Sub-Millisecond Echo Time Musculoskeletal Imaging at 3 Tesla and 7 Tesla
    Deligianni, X.
    Baer, P.
    Scheffler, K.
    Trattnig, S.
    Bieri, O.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (05) : 1434 - 1439