Effect of Maternal Stress on Fetal Heart Rate Assessed by Vibroacoustic Stimulation

被引:10
|
作者
Makino, I. [1 ]
Matsuda, Y.
Yoneyama, M.
Hirasawa, K. [2 ]
Takagi, K.
Ohta, H.
Konishi, Y. [3 ]
机构
[1] Tokyo Womens Med Univ, Med Ctr E, Dept Obstet & Gynaecol, Arakawa Ku, Tokyo 1168567, Japan
[2] Tokyo Womens Med Univ, Dept Paediat, Tokyo 1168567, Japan
[3] Doshisha Univ, Ctr Baby Sci, Kyoto 602, Japan
关键词
MATERNAL STRESS; MATERNAL ANXIETY; STATE-TRAIT ANXIETY INVENTORY; FETAL HEART RATE; VIBROACOUSTIC STIMULATION; CORTICOTROPIN-RELEASING HORMONE; PITUITARY-ADRENAL AXIS; PRENATAL STRESS; ACOUSTIC STIMULATION; GESTATIONAL-AGE; NONSTRESS TEST; LATE PREGNANCY; ANXIETY; TERM; MOVEMENTS;
D O I
10.1177/147323000903700614
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
This study was designed to determine whether maternal stress levels, state and trait anxiety levels, and stress hormones affect fetal heart rate (FHR) patterns after vibroacoustic stimulation (VAS) at 30 weeks of gestation. A total of 24 healthy pregnant women with a single fetus pregnancy were enrolled. Corticotropin releasing hormone (CRH) and adrenocorticotropic hormone in maternal plasma and cortisol, and chromogranin A in saliva were measured. The FHR patterns after VAS were divided into three types: type I, a long period of acceleration or one acceleration lasting > 1 min or at least two accelerations lasting > 15 s; type II, a biphasic response with acceleration followed by deceleration; and type III, no response or prolonged deceleration. In the high trait anxiety group, CRH levels were significantly higher than in the low trait anxiety group, and FHR patterns after VAS showed mostly a type II response pattern. These findings suggest that stress in pregnant women with high trait anxiety may influence FHR patterns after VAS.
引用
收藏
页码:1780 / 1788
页数:9
相关论文
共 50 条
  • [1] The effects of maternal depression on fetal heart rate response to vibroacoustic stimulation
    Allister, L
    Lester, BM
    Carr, S
    Liu, J
    [J]. DEVELOPMENTAL NEUROPSYCHOLOGY, 2001, 20 (03) : 639 - 651
  • [2] Fetal heart rate after vibroacoustic stimulation
    Hoh, Jeong Kyu
    Park, Young-Sun
    Cha, Kyung-Joon
    Park, Moon-Il
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2009, 106 (01) : 14 - 18
  • [3] The effect of vibroacoustic stimulation on fetal heart rate parameters utilizing computer analysis
    Barton, JR
    Hiett, AK
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 1997, 14 (04) : 229 - 232
  • [4] Fetal habituation to vibroacoustic stimulation in relation to fetal states and fetal heart rate parameters
    van Heteren, CF
    Boekkooi, PF
    Jongsma, HW
    Nijhuis, JG
    [J]. EARLY HUMAN DEVELOPMENT, 2001, 61 (02) : 135 - 145
  • [5] THE FETAL SOUND ENVIRONMENT DURING VIBROACOUSTIC STIMULATION IN LABOR - EFFECT ON FETAL HEART-RATE RESPONSE
    GAGNON, R
    BENZAQUEN, S
    HUNSE, C
    [J]. OBSTETRICS AND GYNECOLOGY, 1992, 79 (06): : 950 - 955
  • [6] Effects of maternal smoking on the fetal heart rate response to a vibroacoustic stimulus
    Browne, CA
    Colditz, PB
    Dunster, KR
    [J]. PRENATAL AND NEONATAL MEDICINE, 1999, 4 (05): : 405 - 410
  • [7] VIBROACOUSTIC STIMULATION IN HIGH-RISK PREGNANCIES - MATERNAL PERCEPTION OF FETAL MOVEMENTS, FETAL HEART-RATE AND FETAL-OUTCOME
    NYMAN, M
    ARULKUMARAN, S
    JAKOBSSON, J
    WESTGREN, M
    [J]. JOURNAL OF PERINATAL MEDICINE, 1992, 20 (04) : 267 - 274
  • [8] DETERMINANTS OF FETAL HEART-RATE RESPONSE TO VIBROACOUSTIC STIMULATION IN LABOR
    RICHARDS, DS
    CEFALO, RC
    THORPE, JM
    SALLEY, M
    ROSE, D
    [J]. OBSTETRICS AND GYNECOLOGY, 1988, 71 (04): : 535 - 540
  • [10] Electrocortical and heart rate response during vibroacoustic stimulation in fetal sheep
    Bauer, R
    Schwab, M
    Abrams, RM
    Stein, J
    Gerhardt, KJ
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1997, 177 (01) : 66 - 71